The same reading, and only one of them gives it back
A Venturi and an orifice plate at the same diameter ratio, with the pressure along the axis drawn beneath each. Both narrow the flow by the same amount, both read the same difference between the pipe and the narrowest section, and both infer the same flow rate from it. Downstream they part company: the Venturi's diffuser turns the throat's speed back into pressure, and the orifice's jet expands into the pipe and destroys 73% of the reading. The picture is a section rather than a solved field: nothing here computes the jet, and the recirculating corner is not drawn.
2 essays call
meter. The drawing above is what it returns with no arguments at all; every
call below passes it something, because a placement that passes nothing draws whichever member
of the family the generator happens to default to rather than the one its essay argues about.
It is also the blast radius. Changing meter changes every figure listed here
at once, and on this site it may change what they assert as well as what they show —
which is what has to be rebuilt and looked at before the change is believed.
Where it is called
What each of these essays asks for instead of the defaults is on the regime index, which reads the parameters back out of the finished figures rather than out of the placements.
- The hole that halves the flow Fluids at work
- The price of knowing the flow rate Fluids at work