Series

Metering — the series

3 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. The same reading, and only one of them gives it back. A Venturi and an orifice plate at the same diameter ratio, with the pressure along the axis drawn beneath each. Both narrow the flow by the same amount, both read the same difference between the pipe and the narrowest section, and both infer the same flow rate from it. Downstream they part company: the Venturi's diffuser turns the throat's speed back into pressure, and the orifice's jet expands into the pipe and destroys 73% of the reading. The picture is a section rather than a solved field: nothing here computes the jet, and the recirculating corner is not drawn.

    The price of knowing the flow rate

    Two flowmeters can narrow a pipe by the same amount, read the same pressure difference and infer the same flow rate, and cost pressures that differ by an order of magnitude. What separates them is not viscosity, and not workmanship — it is whether the flow is decelerated or abandoned.

    part 1 · applied
  2. The tunnel makes the stream 7.4% faster. The flow past a cylinder between two walls, solved from the closed form of an infinite image row rather than from a truncated sum. The walls are streamlines exactly — that is what the images are for, and the normal velocity on them is zero to the last bit — and the flow beside the body is squeezed between the body and the wall, which is the whole of the blockage effect. The stream at the model is 7.40% faster than the speed the tunnel's own instruments report far upstream.

    The instrument in the answer

    A model in a wind tunnel is not a model in the sky. The walls are supplied by an infinite row of reflections, the stream at the model is faster than the tunnel's own instruments report, and the correction is not an empirical fudge — it is a series with a closed form.

    part 2 · applied
  3. Five approach profiles a meter might be looking at. The velocity across the pipe upstream of a contraction, for a uniform flow, fully developed laminar flow, two turbulent power laws and an annular jet of the kind a bend or a partly open valve leaves. All five carry the same volume flow. The meter reads a pressure difference and cannot see any of this.

    The profile a meter cannot see

    A differential-pressure flowmeter measures a force balance and reports a flow rate. The step between them needs two integrals of a velocity profile the instrument has no access to — and two profiles differing by half the mean velocity across the pipe give identical readings, which is why the standards specify straight pipe rather than a correction.

    part 3 · applied