Compressible flow

A detonation cell keeps its spike and stretches its induction zone

A real detonation's leading shock is never the steady one: along each cell it starts strong after a collision of transverse waves and decays to its weakest before the next. Averaged over the cell, at the same mean speed, the spike's pressure comes out within four per cent of the steady theory's. The induction zone behind it does not: in hydrogen–air it comes out two and a half times the steady length, half of it from the cell's last fifth, and the factor grows exponentially with the fuel's activation energy. A cell is a pressure average and an induction-zone maximum.

Worth reading first: A detonation's front is at twice its pressure and half its heat · A gas that has not decided to react yet.

A detonation’s front is at twice its pressure and half its heat followed one steady wave through its structure. Stoichiometric hydrogen and air, struck at 1968 m/s, are compressed by an inert shock to the von Neumann spike, 27.3 bar and 1635 K in the two-γ model, and then burn along the Rayleigh line down to the Chapman–Jouguet state at 15.6 bar, where the products leave at the local sound speed. That picture is exact for a planar wave and it is the one every textbook draws, with the induction zone as a short plateau behind the spike whose length, as a gas that has not decided to react yet showed, is an exponential of the spike’s temperature.

No real detonation is planar. A soot-coated plate placed in a tube records a fish-scale pattern of cells, each bounded by the tracks of triple points where transverse waves sweep across the front. Inside a cell the leading shock is a curved piece of Mach stem just after two transverse waves collide, strong and overdriven; it then weakens as it expands, becoming an incident shock that decays below the Chapman–Jouguet speed by the end of the cell, where the next collision restores it. The steady wave is what the cell averages to in speed. Whether it is what the cell averages to in anything else is the question here, and the answer depends on which quantity is asked about. The spike’s pressure and temperature average to the steady values within a few per cent. The induction zone averages to something two and a half times longer in hydrogen–air and far longer in hydrocarbons, and the reason is the exponential in the clock, which makes the average of a cell a statement about its weakest moment.

A shock that averages the Chapman–Jouguet speed

The leading shock’s history along a cell’s centreline is prescribed here, in the shape two-dimensional simulations report: a sharp rise at the collision and a decay that is fast at first and slow towards the end. The speed falls from D0D_0 at the start of the cell to DeD_e at its end as an exponential of decay length ℓ\ell, shifted so that it reaches DeD_e exactly at the end. With D0=1.6D_0=1.6 and De=0.8D_e=0.8 times the Chapman–Jouguet speed, the round numbers usually quoted for regular cells, one more condition fixes ℓ\ell.

That condition is the important one. A cellular detonation is measured to travel at close to the Chapman–Jouguet speed on average, and a comparison between the cell and the steady wave is only fair if it is made at the same mean speed: a profile that averaged faster than CJ would make every averaged quantity stronger for a trivial reason. The cell’s mean speed is its length over the time the shock takes to cross it, which is the harmonic mean of DD along the centreline, not the ordinary one, and ℓ\ell is chosen so that the harmonic mean is exactly DCJD_{CJ}.

A cell's leading shock starts strong, spends most of the cell slow, and still averages the Chapman–Jouguet speed. The leading shock's speed along a detonation cell's centreline, over the Chapman–Jouguet speed of 1968 m/s, falling from 1.3, 1.6 and 2.0 at the collision that starts the cell to 0.8 at its end. Each decay length (1.37, 0.374, 0.238 cell lengths) is the one that makes the cell's length over its crossing time exactly the CJ speed. With the 1.6 start the shock is below CJ over the last 55 per cent of the cell.
Fig. 1 The leading shock’s speed along the cell for three strengths at the collision, each ending at 0.8 times CJ and each with the decay length that makes the cell’s crossing time exactly what a steady wave would take.

For the 1.6 start the decay length is 0.374 of a cell. The shock is above the Chapman–Jouguet speed for the first 45 per cent of the cell and below it for the remaining 55, and because a slow shock takes longer over the same distance, it spends 63 per cent of the cell’s time below CJ. A stronger start must be paid for by a faster decay — 0.238 of a cell for a start at twice CJ — and a gentler one buys a slower decay, 1.37 cells for a start at 1.3. These are not three cells of the same mixture so much as three answers to the question of how much of the uncertainty in a measured profile matters, and the figures below carry the 1.6 case unless they say otherwise.

At each point the leading shock is treated as an inert shock moving at the local speed into the same cold mixture, so the spike state at that point is the one the steady front’s essay computed, at a different DD. That is the assumption the whole calculation rests on, and it is a quasi-steady one: a decelerating shock leaves behind it gas shocked at slightly different speeds, and the gradient this makes across the induction zone is ignored. The section on what the picture leaves out returns to it.

The spike swings by a factor of four and averages within four per cent

The pressure behind an inert shock rises as the square of its speed, so the spike swings strongly across the cell. Just after the collision, at 1.6 times CJ, it is at 70 bar, 2.57 times the steady spike; at the end of the cell, at 0.8 times CJ, it is at 17.4 bar, 0.64 times the steady spike and barely above the burnt gas’s own Chapman–Jouguet pressure of 15.6. The temperature swings less in ratio but over a range that matters more: from 3,750 K, hotter than the burnt products, to 1,150 K, the temperature at which hydrogen and oxygen begin to react only slowly.

The spike's pressure swings by a factor of four across the cell and averages within four per cent of the steady one. The spike's pressure and temperature along the cell, over the steady ZND spike's 27.3 bar and 1635 K, for the shock falling from 1.6 to 0.8 times CJ. The pressure runs from 2.57 to 0.638 times the steady value, 17.4 bar at the end, barely above the burnt gas's 15.6; averaged over the time the front spends it is 1.04 and over distance 1.13. The temperature runs from 2.29 to 0.701 and averages 1.03 in time.
Fig. 2 The spike’s pressure and temperature along the cell, over the steady spike’s 27.3 bar and 1635 K. Both swing widely and both average close to one; the end of the cell is the coldest compressed gas anywhere in the wave.

Averaged over the time the front spends at each point, the spike pressure is 1.040 times the steady value; averaged over distance along the cell, 1.130. The temperature’s averages are 1.033 and 1.107. These are not one, but they are close to one, and they are close for a reason that has nothing to do with detonation: the spike’s pressure is a gentle function of DD, nearly a parabola, and the mean of a parabola over a distribution with a fixed harmonic mean is its value at that mean plus a term in the variance. The variance of a factor-of-two swing is not small, and the 13 per cent excess over distance is that term; the time average weights the slow end more and comes closer.

So a pressure gauge flush with the wall of a tube, placed anywhere along it, sees a time-averaged peak not far from the steady spike, and the steady theory’s twice-the-CJ-pressure rule for the front, which the earlier essay derived in the strong limit, holds for the cell’s average as well as for the planar wave. If the average of everything behaved like this, the steady wave would be a good description of the cell, with a few per cent of scatter on top. The induction zone is where that fails.

Where the induction zone is long

The induction length behind each point of the leading shock is the time the shocked gas waits before reacting, multiplied by the speed at which it leaves the shock. The time is a one-step Arrhenius clock, τ∝eE/RT\tau\propto e^{E/RT}, written with the reduced activation energy θ=E/RTvN\theta=E/RT_{vN} measured at the steady spike, so that the length over the steady ZND length is

ΔΔZND=uvNuvN,CJexp⁡ ⁣[θ(TvN,CJTvN−1)].\frac{\Delta}{\Delta_{ZND}}=\frac{u_{vN}}{u_{vN,CJ}}\exp\!\left[\theta\left(\frac{T_{vN,CJ}}{T_{vN}}-1\right)\right].

Effective activation energies fitted to detailed chemistry put stoichiometric hydrogen–air near θ=5\theta=5 and the common hydrocarbon–air mixtures between about 10 and 12; those two values carry the comparison. The speed factor is modest: a stronger shock compresses the gas a little more but moves it a lot faster, and at 1.3 times CJ with the clock switched off the length would be 1.21 times the steady one. The exponential is not modest.

The induction zone is short where the shock is strong and long where it is weak, and the weak end is longer by moreThe induction length along the cell over the steady ZND length, on a logarithmic scale, for reduced activation energies of 3, 5, 8 and 11 and a shock falling from 1.6 to 0.8 times CJ. At θ = 5 the length runs from 0.085 to 7.39 times ZND, and the front, averaged over the time it spends, carries 2.56 times the steady length; at θ = 11 the cell's end is 95.2 times ZND and the average 18.4.steady ZND00.20.40.60.8110⁻²10⁻¹10⁰10¹10²distance along the cell, in cell lengthsinduction length over the steady ZND oneθ = 3θ = 5θ = 8θ = 11the leading shock's centreline speed prescribed, inert spike at each point, one-step Arrhenius clocka cellular detonation in stoichiometric hydrogen–air at 1 atm, 300 K, averaging 1968 m/s
Fig. 3 The induction length along the cell on a logarithmic scale for four activation energies. The dial moves the cell’s weakest point; the strong start barely changes, and the end of the cell lengthens by an order of magnitude as the weakest shock falls.

At θ=5\theta=5 the induction length is 0.085 of the steady length just after the collision and 7.4 times it at the end of the cell: a factor of 87 across one cell, in a mixture whose spike temperature varies by a factor of three. At θ=11\theta=11 the factor is 2,500. The two ends are not symmetric about the steady value on a logarithmic scale, and that asymmetry is the whole of the result. The shock’s temperature rises faster with speed above CJ than it falls below it, but the exponential of the inverse temperature is steeper on the cold side, so the long zones at the end of the cell are longer, in ratio, than the short zones at the start are short. Dialling the weakest shock from 0.9 to 0.75 of CJ shows the same thing from the other side: the start of the cell does not move, and the end lengthens from 2.4 to 14.7 times the steady zone at θ=5\theta=5.

Half of the induction zone comes from the last fifth

The asymmetry has a direct consequence for where a cell’s induction zone lives. Summed along the cell, the induction length’s total is dominated by the last part, where the shock is weakest and its zone longest.

Half of a cell's induction zone comes from its last fifth. The share of the induction length summed along the cell that comes from its last part, against the size of that part, for activation energies of 3, 5, 8 and 11; the diagonal is a steady wave. At θ = 5 the last fifth of the cell supplies 53 per cent and the last tenth 30; at θ = 11, 77 and 49.
Fig. 4 How much of the induction length summed along the cell comes from its last part. A steady wave lies on the diagonal; the cell’s curves rise steeply from the end, more steeply the higher the activation energy.

At θ=5\theta=5 the last fifth of the cell supplies 53 per cent of the summed induction length and the last tenth supplies 30. At θ=11\theta=11 the last fifth supplies 77 per cent and the last tenth nearly half. A soot foil or a schlieren photograph that showed a thick, ragged reaction zone behind the front would be showing mostly the end of the cell, and a measurement of the front’s thickness that sampled the cell evenly would be a measurement of its weakest part. It is also why the cell must restart. A shock that continued to decay past the end of the cell would carry an induction zone that lengthened without limit, and the reaction would fall behind the shock altogether; a loss slows a detonation only so far, and then it folds found the same cliff in a steady wave whose heat leaked away. The collision at the cell’s end is not a decoration on a steady wave. It is what keeps the last fifth of every cell from becoming that cliff.

The exponential that turns a mean into a maximum

The reason the spike averages well and the induction zone does not is one inequality. For any convex function, the average of the function over a distribution is at least the function of the average, by an amount that grows with the variance and with the curvature. The spike pressure is nearly a parabola in DD and only mildly convex. The induction length is an exponential of an inverse, and steeply convex. The averaged induction zone is therefore larger than the induction zone of the averaged shock by an amount that grows exponentially in θ\theta.

The cell's averaged induction zone grows exponentially with the activation energy. The induction length averaged over one cell, over the steady ZND length, against the reduced activation energy θ, averaged over the time the front spends and over distance, for a shock falling from 1.6 to 0.8 times CJ. At θ = 5, about hydrogen–air's, the time average is 2.56 and the distance average 2.21; at θ = 11, in the range quoted for hydrocarbon fuels, 18.4 and 15.2. At θ = 0 both are near one, since the clock then does not care about temperature.
Fig. 5 The cell-averaged induction length over the steady one against the reduced activation energy, by time and by distance. Both grow exponentially once θ\theta passes a few; the dashed marks are hydrogen–air and the middle of the hydrocarbon range.

With the clock switched off, θ=0\theta=0, the averages are 1.006 by time and 1.033 by distance: the shock’s kinematics alone barely care. At θ=3\theta=3 they are 1.53 and 1.37; at hydrogen–air’s 5 they are 2.56 and 2.21; at 8 they are 6.5 and 5.5; at 11 they are 18.4 and 15.2; at 14 they are 54 and 45. The time average, riding the front, is always the larger, because the front spends longest where its zone is longest.

The sharpest way to see that averaging the shock first gives the wrong answer is to do it. The time-averaged spike temperature is 1.033 times the steady spike’s; a steady wave at that temperature would carry an induction zone 0.85 times the steady length, shorter, while the cell actually carries 2.56 times it. The steady wave that has the cell’s averaged induction zone travels at 0.893 times the CJ speed with a spike at 1,360 K. A reaction zone computed from the mean state of a cellular front is wrong in sign, not merely in size, and the correct equivalent wave is a weak one.

This is where the calculation meets something measured. A detonation’s cell width λ\lambda is correlated with the steady induction length by a factor of a few tens — stoichiometric hydrogen–air’s cells are about a centimetre wide and its ZND induction length is a fraction of a millimetre — and the factor is known to be larger, and the cells more irregular, the higher the activation energy. The averaging computed here supplies a factor of 2.6 at θ=5\theta=5 and 18 at θ=11\theta=11, growing in the same direction. It does not explain the whole of the correlation’s constant, and a factor of a few tens is not a quantity a prescribed profile could derive, but it says that some of the constant is not geometry at all: it is the cell measuring its own induction zone at its weakest moment, while the steady theory measures it at the mean.

The weakest moment decides

If the cell’s averaged zone is set by its weak end, then the shock’s speed at the end of the cell should matter much more than its speed at the start. It does.

The weakest moment of the cycle sets the average, and the strongest barely moves it. The time-averaged induction length over ZND at θ = 5 against the shock speed at the cell's end, for cells starting at 1.4, 1.6 and 2.0 times CJ, each with its decay length set so the cell averages the CJ speed. Lowering the end from 0.9 to 0.75 raises the average from 1.53 to 3.64 at a start of 1.6; raising the start from 1.4 to 2.0 at an end of 0.8 moves it from 2.21 to 3.1.
Fig. 6 The time-averaged induction length at θ=5\theta=5 against the shock’s speed at the end of the cell, for three strengths at the start. The curves are steep in the end speed and close together in the start.

With the start held at 1.6 times CJ, lowering the end from 0.9 to 0.75 of CJ raises the averaged zone from 1.53 to 3.64 times the steady length, a factor of 2.4. With the end held at 0.8, raising the start from 1.4 to 2.0 moves it from 2.21 to 3.10, a factor of 1.4 for a much larger change in speed, and most of that is the indirect effect of the harmonic-mean condition: a stronger start must decay faster, so the shock spends longer near its end speed.

The practical reading is about measurement. Published profiles of the centreline speed agree better on the start of the cell, where the Mach stem is clearly defined, than on its end, where the incident shock is weak, curved and hard to track. The averaged induction zone is most sensitive to exactly the part of the profile that is least well known, so a quoted factor for the averaged zone is only as good as the end speed it was computed with. A cell whose end speed is 0.9 of CJ and one whose end speed is 0.75 have indistinguishable mean speeds and averaged spike pressures, and induction zones that differ by more than a factor of two.

Two averages, and which one is meant

Every average above comes in two kinds, and the distinction is a convention that has to be stated because it changes the answer. A gauge at a fixed point in the tube meets the front at a random place in the cell, uniformly in distance; its record of many cells is the distance average, ∫X ds\int X\,ds over a cell of unit length. An observer riding the front, or a simulation that averages the front’s state over time, spends longer where the front is slow; that is the time average, ∫X ds/D\int X\,ds/D divided by ∫ds/D\int ds/D. For the spike pressure the two differ by nine per cent; for the induction length at θ=5\theta=5 by sixteen.

The time average is the right one for the question of what the reaction zone behind the front is on average, because the reaction zone belongs to the front and moves with it; it is the one the refutation above quotes. The distance average is the right one for what a set of wall gauges or a soot foil samples. The same distinction, between an average weighted by where things are and one weighted by what passes, is the one two averages of one flow found between a hot wire’s mean velocity and a density-weighted one, and it is the general form of the point the mean is not the flow makes: an averaged state is a new object, and it is not the state of any wave.

The other conventions are the ones inherited from the steady essay: the two-γ hydrogen–air with its heat release fitted to 1968 m/s, speeds over the CJ speed, induction lengths over the steady ZND length at the same CJ speed, and the activation energy reduced by the steady spike’s temperature, so that θ=5\theta=5 means the same clock at every point of the cell.

What the prescribed profile leaves out

The shock’s history is prescribed, not computed, and the profile is a smooth exponential where real cells show a sharper rise, an inflection and, in irregular mixtures, a decay interrupted by local explosions. The answers depend on that shape, most of all through the end speed, and the honest statement is the one the weakest-moment figure makes: the factor of 2.6 belongs to a profile ending at 0.8 of CJ, and the factor’s sensitivity to the end is larger than its sensitivity to anything else in the model.

The quasi-steady spike is the second simplification. A decelerating shock is followed by gas that was shocked when the shock was stronger, so the gas at the end of the induction zone is hotter than the spike at the shock; the true zone behind a decaying shock is shorter than the local quasi-steady one, by an amount that grows with the deceleration. The correction is largest exactly where the induction zone is longest, so it would reduce the averaged factor, and the size of that reduction is not computed here.

The clock is one-step. Real hydrogen–oxygen chemistry has a chain-branching crossover near 1,100 K at these pressures, below which the induction time rises far more steeply than a single activation energy allows; the end of the cell, at 1,150 K, sits just above it. A clock that knew about the crossover would make the end of the cell longer still. A clock with a pressure dependence, the bimolecular form that scales the time with the inverse of the density, raises the averaged factor at θ=5\theta=5 from 2.56 to 2.73, because the end of the cell is also the least compressed gas. And the calculation is on the centreline only. The rest of the cell, off the centreline, is crossed by the transverse waves themselves, whose own shocked gas has a different history; when a shock cannot bounce described the triple-point geometry that the transverse waves carry, and none of it is in a one-dimensional profile.

How it was checked

A detonation cell's averages: the checks. The steady wave's induction length against one, the cell's crossing time against the CJ time, the small-swing average against its second-order expansion, and the spike at CJ against the steady spike.
Fig. 7 The constant wave’s induction length against one, the cell’s crossing time against the CJ time, the small-swing average against its expansion, and the spike at CJ against the steady essay’s.

A wave that does not vary returns the steady induction length to machine precision, and the spike at the CJ speed is the steady essay’s 27.3 bar and 1635 K, which sit within eight per cent of the published 27.9 bar and 1530 K. The decay length was found by bisection on the harmonic mean, and the cell’s crossing time comes back as the steady wave’s to six figures. For a small swing — a start at 1.006 and an end at 0.997 of CJ — the averaged zone’s excess over one agrees with the second-order expansion 12[(ln⁡Δ)′′+((ln⁡Δ)′)2] var(D)\tfrac12[(\ln\Delta)''+((\ln\Delta)')^2]\,\mathrm{var}(D), the time-weighted variance, to within one per cent of the excess, the rest being the profile’s skewness at third order. With the clock switched off the induction length is the shock’s kinematic factor alone, and the averages come out within a few per cent of one, which is the statement that the whole of the large effect is the clock’s.

Denisov, Troshin, Shchelkin and the cell’s averages

The steady structure is Zel’dovich’s of 1940, von Neumann’s of 1942 and Döring’s of 1943. The cells were found in the late 1950s, by Denisov and Troshin’s soot-foil records and Voitsekhovskii’s studies of spinning detonation, and Shchelkin and Troshin proposed soon after that a cell’s size should scale with the induction length, which is where the correlation with a large constant began. The link between the activation energy and the front’s instability is Erpenbeck’s linear stability analysis of the 1960s and the one-dimensional pulsating waves computed from the 1970s onwards; the centreline histories of the leading shock that the profile here imitates come from two-dimensional simulations of the 1990s and 2000s, among them those of Gamezo, Desbordes and Oran and of Radulescu and colleagues, who also made the case that irregular cells in high-activation-energy mixtures burn partly by turbulent mixing of unreacted pockets rather than behind the shock. That the steady zone underestimates a cell’s mean zone, and by more for sensitive mixtures, is part of that literature’s argument; the quantitative factor for a stated profile, and the sign reversal when the shock is averaged first, are this calculation’s.

The flame-front instability that underlies the cell is the one a flat flame is unstable at every size followed for a deflagration; the sensitivity of the clock that turns a small change of shock speed into a large change of length is the induction essay’s subject, and its relative for a gas whose vibration lags the shock is a gas that has not finished being shocked; and the convex averaging that makes a mean dominated by its extremes is the shape a dissipation correlated across every scale found in turbulence’s energy dissipation, where the average of a cascade is likewise set by its rare intense parts.

Still open: the profile the cell would choose

Every number here comes from a profile put in by hand. The cell chooses its own: its end speed is set by how far the incident shock can decay before the reaction behind it decouples, and that is itself set by the induction zone the decay produces. The next calculation would close the loop with a one-dimensional model of the decaying shock in which the reaction zone feeds back on the shock’s speed — a blast-wave decay from the collision, with the heat released behind the shock after the local, history-dependent induction delay — and find the end speed at which the decay is arrested by the delayed heat release. It would ask whether that end speed falls as the activation energy rises, as the irregular cells of hydrocarbon mixtures suggest, and so whether the averaged induction zone’s exponential growth is steeper still once the cell sets its own weakest moment.

Shares its objects with

Essays naming at least two of the same things, that neither author linked.

Named objects

A dashed tag is an object no other essay names yet.