A tube wall carries heat upstream only half its own thickness
Worth reading first: A steel wall lengthens a sodium entrance by half · How far before the heat arrives.
A steel wall lengthens a sodium entrance by half: a liquid metal carries heat across a pipe by conduction, as the other layer does when the Prandtl number is small, steel conducts about a quarter as well as sodium, and a wall in series with the fluid changes the condition the fluid sees from a fixed temperature towards a fixed flux. The thermal entrance grows by half at the most, at a wall Biot number near two, which is where sodium in a steel tube happens to sit. That wall could carry heat only across itself. A real wall carries heat along itself as well, and at the low Péclet numbers where a liquid metal’s entrance is longest, the wall’s axial conduction looks comparable with the fluid’s own.
That raises a question the radial calculation could not ask. If the heating is switched on at a station on the outside of the tube, the wall can carry some of it upstream, so the fluid starts to warm before the heated section begins. Measured from the step, the entrance might then shorten rather than lengthen, the heat having begun its journey early. And there might be a ratio of wall to fluid conductance at which the wall’s axial path, rather than the fluid’s, decides where the heating begins. The answer is that the wall’s path does decide where heating begins — at a distance of about half its own thickness — and moves the entrance not at all.
One conductivity, two paths
The fluid is in slug flow at speed in a tube of radius , as a liquid metal at low Prandtl number nearly is, with its own axial conduction kept: in units of the radius, with . The wall is thin, of thickness and conductivity , and is lumped across its thickness: its temperature is joined to the outside and to the fluid’s surface by half its radial conductance each, and it conducts along itself.
with , the wall’s radial conductance against the fluid’s, and , its axial conductance against the fluid’s. The outside temperature steps from 0 to 1 at .
The two numbers are not independent. Their ratio is , the wall’s thickness squared, for any material. A wall that conducts well along its length conducts equally well across it, and its axial conductance cannot be raised against its radial one except by making it thicker. Copper conducts twenty times better than steel along the wall and twenty times better across it, and in the ratio the material drops out.
Solved exactly
The equations are linear, as the heat of a squeeze leaves across the gap is, and their coefficients do not depend on , so they are solved exactly by a Fourier transform along the pipe. The fluid’s transformed temperature is with , and the wall and the fluid’s surface give two algebraic equations; their solution is the bulk temperature’s transfer function from the outside temperature, one at zero wavenumber. Inverted on a periodic domain twenty-four times the Péclet number long and integrated, it is the bulk temperature’s response to the step.
The rates at which that response decays far from the step are the roots of a dispersion relation: for a mode upstream, , and the wall’s balance becomes one real equation for . Both were checked against what is known exactly. With no axial conduction in the wall, the fluid’s approach to full heating downstream must decay at , with the first root of , and the transform’s tail does, to at Pe = 50; the dispersion relation’s roots on both sides match their closed forms to . With the wall conducting, the transform’s tail and the dispersion relation’s root agree to .
The entrance does not move
The figure answers the practical question at once. For sodium in steel a tenth of the radius thick, at a Péclet number of 50 on the radius — about 100 on the diameter, a typical sodium loop — the bulk temperature reaches half its rise 10.82 radii downstream of the step with the wall’s axial conduction and 10.82 radii without it, the same to four figures. At walls 0.2 and 0.3 of the radius thick the half-rise moves to 17.96 and 24.97 radii, and again identically with and without. A copper wall of the same thickness reaches half its rise far sooner, at 3.6 to 4.4 radii — but because it resists less across, the effect the radial calculation found, not because it conducts along.
Across Péclet numbers from 1 to 500 and three walls — steel a tenth and three-tenths of the radius thick, and copper a fifth — the downstream approach rate with the wall’s axial conduction differs from the rate without by at most 0.75 per cent, and that only for the thick steel wall at Péclet numbers of one or two. At 50 every wall is within a hundredth of a per cent. The wall’s axial path does not touch the entrance. What sets the entrance’s length is the slowest mode downstream — how far before the heat arrives in the first place — a smooth radial profile decaying over many radii, and over many radii a thin wall’s axial conduction is nothing beside the heat it passes across.
Where the heating begins
The axial path does change something: where the fluid starts to warm. Upstream of the step the fluid’s temperature falls away as , and is how far upstream the heating reaches.
With the outside held at the inlet temperature upstream of the step, the reach settles, at high Péclet number, on almost exactly half the wall’s thickness: 0.052 radii for the steel wall a tenth of the radius thick, 0.154 for the one three-tenths thick, 0.126 for copper a fifth thick. The limit is a fin’s. A wall between a held outside and a fluid that cannot warm in time loses its axial heat to both faces, through half its thickness each, and a fin of axial conductance losing through a conductance decays as with . With that is — half the wall’s thickness, whatever the wall is made of. At a Péclet number of 2,000 the computed reach is 0.98 of it.
The fluid has its own upstream reach, by its own axial conduction, of about : 0.02 radii at Pe = 50. So the wall’s path does set where the heating begins whenever half its thickness exceeds the fluid’s reach — whenever , a criterion with no conductivities in it. For sodium in steel a tenth of the radius thick that is any Péclet number on the radius above 20. It is the answer to the question of which path decides, and it is a strange answer: the wall decides, at a distance of a twentieth of a radius, in front of an entrance two hundred times longer.
Insulated upstream
A tube heated over a section usually has its outside insulated upstream rather than held cold, and then the wall loses its axial heat only to the fluid.
The reach grows, but not by much for steel: 0.079 radii instead of 0.052 for the thin wall at Pe = 50, 0.225 instead of 0.154 for the thick. A liquid metal takes heat from the wall’s inner face almost as fast as the wall’s own half-thickness can deliver it, so losing the outer face only halves the fin’s conductance and lengthens its reach by , to about .
Copper in slow flow is the exception the question was looking for. With twenty times steel’s conductivity and a fifth of the radius of thickness, its axial conductance is the fluid’s radial one, ; at a Péclet number of 2 the fluid takes up the wall’s heat slowly, and the reach becomes the fluid’s uptake rather than the wall’s thickness. There the dispersion relation reduces to , so , a reach of , and the computed reach is 1.61 radii. That is the only case here in which a wall’s axial path preheats a liquid metal over a distance comparable with the pipe’s radius — a thick, highly conducting wall, an insulated approach and a creeping flow — and even there the entrance downstream is unchanged to a fraction of a per cent.
Millimetres in a sodium loop
In a sodium loop the numbers are small enough to state in millimetres. Sodium at 400 degrees Celsius has a thermal diffusivity of about square metres a second, so a Péclet number of 50 on a radius of 10 millimetres is a speed of a third of a metre a second. Through a steel wall a millimetre thick, the bulk temperature reaches half its rise 108 millimetres downstream of the step, with or without the wall’s axial conduction. The fluid’s temperature upstream of the step falls by a factor of e in 0.52 millimetres with the outside held, and 0.79 with it insulated: the heating begins half a millimetre early, in front of an entrance a tenth of a metre long. A thermocouple placed a few millimetres upstream of a heated section to read the inlet temperature reads it uncontaminated, whatever the wall.
The same arithmetic shows when the inlet reading would be contaminated. A copper section two millimetres thick, insulated upstream, in sodium creeping at Pe = 2, preheats the fluid over 16 millimetres: there a thermocouple placed one diameter upstream reads a little of the heater. That is a low-flow test condition rather than an operating one.
A fluid that conducts poorly
The argument does not need a liquid metal. With the outside held, the reach is the wall’s alone, half its thickness, for any fluid. For water in a steel tube a tenth of the radius thick it is 0.065 to 0.095 radii across Péclet numbers from 1,000 to 10 — half the thickness, slightly lengthened at the lowest flow by the water’s own conduction.
Insulated upstream, the fluid’s uptake matters, and a fluid that conducts poorly takes up less. Water conducts thirty times less well than sodium, so the same steel wall is, relative to water, a strongly conducting wall: its axial conductance is 2.7 times the water’s radial one. Its insulated reach is then 1.08 radii at a Péclet number of 10, 0.44 at 100 and 0.21 at 1,000. The entrance downstream is untouched even so — 17.43 radii to the e-folding of the approach at Pe = 100, with and without — because in water the entrance is long for a different reason — a duct forgets everything but one number slowly — the slow flow of heat across the pipe, and the wall’s axial path never reaches it.
Why the obvious estimate is wrong
The intuition behind the question was a comparison of conductances: steel’s axial conductance, , against sodium’s, , gives for a thin steel wall, small but not negligible, and at low Péclet numbers the fluid’s own axial conduction is what makes a liquid metal’s entrance long. The flaw is that the wall’s axial heat must stay in the wall to travel, and a thin wall in contact with a held outside or a well-conducting fluid cannot keep it: the radial conductance that empties it is larger than the axial conductance that carries it by , a hundred for a wall a tenth of the radius thick. The relevant comparison is not of the wall’s axial conductance with the fluid’s, but of the wall’s axial conductance with its own radial one, and that comparison is fixed by geometry.
The radial effect survives untouched
The calculation also redoes the radial result with the axial path added, and the radial result is unchanged. Between the thin steel wall and a copper one of the same thickness, the half-rise moves from 10.82 radii to 3.57: copper’s Biot number is twenty times steel’s, so it holds the fluid’s surface far closer to the outside’s temperature and the fluid heats faster. That is the effect the series resistance produces, and the lengthening by up to a half that the radial calculation found for a sodium loop’s steel wall is part of it. Adding the wall’s axial conduction to either wall changes the half-rise in the fifth figure.
So the two properties of a wall act on two different things. Its radial resistance acts on the whole entrance, because every unit of heat the fluid receives has to cross the wall. Its axial conductance acts only within a wall thickness or so of where the heating changes, because only there is there a gradient along the wall to drive it. A designer worried about a liquid metal’s entrance should choose a wall for its resistance across; its conductance along is settled by the same choice and does not need checking.
What the thin wall cannot show
The wall is lumped across its thickness, which is exact only for variations along the pipe slower than the thickness. The upstream reach computed here is half the thickness, which is precisely the scale at which the lumped wall stops being exact: a wall resolved in two dimensions has a temperature that varies across it near the step, and its reach is of the same order but not exactly . The conclusion — that the reach is of order the thickness and independent of the material — survives, because it rests on the ratio , which a resolved wall shares.
The flow is slug flow. A laminar liquid metal at moderate Péclet number has a parabolic profile; a turbulent one is nearly flat but with eddy conduction near the wall, the heat the eddies do not carry at these Prandtl numbers. Both change the fluid’s uptake and so the insulated reach, not the held one, which is the wall’s. The outside is a sharp step of temperature; a real heater’s edge is spread over its own length, which smooths the step on the scale of the heater rather than the wall. And the contact between wall and liquid metal is perfect, which in sodium loops it is not always: a contact resistance adds to the radial path and lengthens the reach.
The quantities in the numbers
The Péclet number is on the radius, ; it is half the one on the diameter that heat-transfer correlations use. Bi and are the wall’s radial and axial conductances over the fluid’s radial one, per unit area and along, with for steel and sodium and 5 for copper and sodium. The upstream reach is the e-folding distance of the fluid’s temperature upstream of the step, from the smallest root of the dispersion relation; the half-rise is where the bulk temperature reaches half the outside’s. The outside temperature is held, so the downstream state is a fully heated fluid at the outside’s temperature.
Who worked on it
The conjugate problem, a wall conducting in two directions between a fluid and an outside, was treated for laminar pipe flow by Davis and Gill in 1970 and by Faghri and Sparrow in 1980, who showed that axial conduction in the wall carries heat upstream of a heated section and that it matters for thick walls in slow flows. Liquid-metal heat transfer, with its long entrances and its axial fluid conduction, was developed for fast reactors from the 1950s by Lyon, Seban and Shimazaki and others. The geometric ratio is the reason their thick-wall cases were the interesting ones, and the same thin-wall lumping holds a pipe that cannot keep its gas at the wall’s temperature.
Still open: a wall thick enough to matter
The only way to give a wall a long upstream reach is to make it thick, and a thick wall cannot be lumped. The calculation that would follow solves the wall as a two-dimensional annulus, in radius and length, joined to the fluid’s transform at its inner face, and asks how the reach grows once the thickness is comparable with the radius — whether it saturates at some fraction of the outer radius, so that a massive copper block round a thin sodium channel preheats the flow over its own size, and whether the entrance downstream then shortens at last. That is the geometry of a heat-exchanger tube sheet, where the fluid enters through a thick plate at a different temperature from the fluid it is entering.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- A bowed meniscus keeps most of its slip until the groove floods — both name boundary condition, model limit
- A bubble is throttled by its age, and a sheet by its length — both name model limit, peclet number
- A cap that slows a rising bubble stops a migrating one — both name boundary condition, model limit
- A flat flame is unstable at every size — both name eigenvalue, model limit
- A flow pinned between two guesses — both name boundary condition, model limit
- A length you can only measure by squeezing — both name boundary condition, model limit
Named objects
A dashed tag is an object no other essay names yet.
Boundary conditionEigenvalueLiquid metalModel limitPeclet numberThermal entry length