In the lab the liquid runs into the bubble's edge head on; riding with the bubble it flows round a cylinder. Streamlines of the liquid around a circular bubble in a Hele-Shaw cell, upper half. Left, in the lab frame, the liquid moving at U far away: every streamline meets the bubble's edge at right angles, because the edge is a line of constant pressure. Right, in the frame of the bubble, moving at 2U: the same flow is uniform flow past a solid cylinder at speed U, and the edge is a streamline. Ideal flow

A bubble between two plates runs at twice the liquid

Squeeze a bubble between two glass plates a fraction of a millimetre apart and push liquid past it. The bubble does not drift with the liquid. It runs ahead of it at exactly twice the liquid's speed, whatever its size, whatever the liquid's viscosity and however wide the gap — and an elliptical bubble runs at one plus its length over its width. The reason is that the flow between the plates is a potential flow whose potential is the pressure, and a bubble, with one pressure inside it, is a conductor in a uniform field.

A modest spread of heights barely smooths Nikuradse's dip; Colebrook's curve needs heights spread over two decades. The roughness function ΔU⁺ against the equivalent sand roughness in wall units, for log-normal populations each element of which follows Nikuradse's own transition, their shifts added by area: σ = 0 (uniform sand), 0.47, 1 and 2.2, with Colebrook's function. A spread of 0.47 is still 1.76 below Colebrook's at its worst; 2.2 fits it to 0.18 everywhere. Transition and turbulence

The Moody chart would need a wall spread over two decades

Nikuradse's uniform sand stays smooth until its grains poke through the viscous sublayer and then dips before it rises. Colebrook's commercial pipes, on which the Moody chart is drawn, feel their roughness from the first fraction of a wall unit and never dip. The natural explanation is that a commercial wall is a population of heights, and the tall ones start early. Built element by element from Nikuradse's own transition, a population reproduces Colebrook's curve only if its heights span a factor of eighty between the middle two-thirds of the elements — and measurements of real pipes since 2006 suggest they do not.

A kick sends half its energy away as sound if it is sudden, and almost none if it lasts. The share of the energy delivered by a body force on a blob of radius R that leaves as sound, against the pulse's duration T times the sound speed over R, for three pulses carrying the same impulse. All start at one half. At cT/R = 1 the Gaussian pulse's share is 0.333, at 10 it is 0.0098, and the line is the closed form 1/(2 + (cT/R)²). The abrupt top hat keeps more: 0.0178 at 10. Flows and fields

A kick that lasts makes no sound, by an inverse square

Push a blob of air suddenly and half the energy delivered leaves as sound, because half the push compresses the air and compression in a compressible fluid cannot stay. Push it for longer and less leaves. How much less is a clean law: for any push that starts and stops smoothly, the sound's share falls as the inverse square of how many times the sound could have crossed the blob while the push lasted. A push switched on abruptly breaks the law by a logarithm, because its edges ring at every frequency however long it lasts.

Emptied through the same supply, the row comes down a different sawtooth and the two enclose a loop. The supply's pressure, in units of the wall's stiffness over the radius, against the total air in six balloons whose unstretched radii differ by up to ±3 per cent: filling, then emptying at the same slow rate. Going up, the teeth top out at the balloons' peaks near 0.75; coming down, the teeth bottom out at their troughs, 0.65, 0.642, 0.634, 0.626, 0.619, 0.611. The area between the two legs, 47 in these units, is the work the pump put in and did not get back. What is taught wrongly

A row of balloons empties by its troughs, and a crowd wastes more than a pair

Blow up a row of balloons from one pump and they fill one at a time, largest first. Let the air out again through the same pump and they do not simply run the film backwards. They shrink together, then collapse one at a time, each at the bottom of its own pressure curve rather than the top. The order that results is the reverse of the filling order only when the balloons differ in size alone; a wall that stiffens eight per cent more on the larger balloons makes the row empty in the order it filled. And the air-work lost in a cycle is not a property of a balloon but of how many share the pump.

Beside mid-chord, the error is a function of the gap over the panel size and nothing else. The size of the lift error, panels against the exact linearised lift, for a flat plate with a free vortex under its mid-chord, against the vortex's distance from the plate divided by the panel length, for 8 to 128 panels. The five curves lie on one another: 8.7 per cent at half a panel, 0.38 per cent at one. The dip near two panels is where the error changes sign; past it the error is below a quarter of a per cent for every count from 8 up, and the curves part, because a gap of several panels is no longer small against the chord. Circulation and lift

A panel can live with a neighbour one panel away, except at the edge

A lumped-vortex panel is exact for any onset flow that varies linearly across it, and a neighbouring vortex makes the onset flow curve over a length equal to its distance. So the natural rule is that a panel should be no longer than the gap to the nearest neighbour, and beside the middle of a chord that rule is exactly right: the lift error depends on the gap over the panel length and on nothing else, a third of a per cent when the two are equal. Under the leading edge the rule fails, and the reason is the edge's own singularity rather than anything about the neighbour.

Shaped for its cruise lift, the pair pays exactly a flat plate's drag due to lift there, and pays something at zero lift. Wave drag against lift at Mach 1.944, per unit of one element's chord, for the pair designed for 2° and the tilted symmetric pair, beside a single flat plate carrying the same lift, whose drag is β/4 times the square of its lift coefficient, and a diamond 6 per cent thick. At the design lift, 0.0838, the designed pair's drag is 0.002924, the flat plate's exactly; the tilted pair's is 0.003286. At zero lift the designed pair has a drag of 5.71·10⁻⁴ where the symmetric pair has none. Compressible flow

A Busemann pair shaped for its cruise pays a flat plate's drag and no more

Tilt Busemann's biplane to make it lift and its channel stops cancelling its own waves: the lift is still all on the outer faces, but the inner faces now cost drag. Reshape the two elements for the incidence they will cruise at — the lower apex moved forward, the upper apex aft, the upper element set ahead of the lower — and the channel at that incidence is Busemann's cancelling channel again, seen from the stream. Its drag due to lift falls to exactly what a single flat plate pays for the same lift, the least a two-dimensional section can pay in linear theory. The price is a drag at zero lift, a narrower Mach bucket, and a starting Mach number that falls to the design Mach number itself.

In a long shallow tank most of the water sloshes, and the leaking cart brakes in every cycle. The cart's acceleration for the same cubic metre of water in a tank 4 m long and 0.25 m deep: 80 per cent of the water is in the sloshing mode, whose period is 5.14 s. The first acceleration is 3.67 times the rigid value, and in every cycle the returning water pushes the cart backwards, at up to 6.7 mm/s², although the thrust never changes sign. Flows and fields

A leaking cart leaps ahead of its own water

Open a hole in the back of a water tank on a cart and the cart's first acceleration is not the thrust divided by the cart and its water. Part of the water does not move with the tank at once: it sloshes, and until it does the thrust has less mass to push. In a cubic tank on a light cart the first acceleration is thirty per cent above the rigid value; in a long shallow tank it is more than three and a half times, and in every slosh the returning water pushes the cart backwards although the jet never stops pushing it forwards. The momentum inside the box is not its mass times the box's speed, and the transport theorem says exactly how much it is not.

The calmed region leaves the start of transition alone and drags out its end. Intermittency, the share of time a station is turbulent, against distance downstream of the start of breakdown, for spots born uniformly at n = 0.005: Emmons's formula, the Monte Carlo without calming (within 0.018 of it everywhere), the Monte Carlo with a calmed region whose rear moves at 0.3 of the stream, and the mean-field estimate for it. The two Monte Carlos agree to γ = 0.2; by γ = 0.8 the calmed plate lags by 0.04. Dialled through rear speeds of 0.2, 0.3 and 0.4, a slower rear leaves a longer calm and a longer tail. Transition and turbulence

The calm behind a spot refuses a quarter of the births and moves only the end

Every turbulent spot on a plate drags behind it a region of unusually steady laminar flow in which no new spot can start. Counted as a Monte Carlo of Emmons's spots, the calmed region refuses a quarter of all the births that would otherwise have happened, and nearly half of them in the middle of the transition. Yet the intermittency hardly notices: the start of transition does not move at all, and its end is drawn out by nine per cent. Most of the births a calmed region refuses were going to be swallowed by the spot ahead of them anyway. The part that is not is a measurement of how long the calm lasts.

At Shields' own number, a pebble in any measured pocket is out of it a quarter to a half of the time. The fraction of time the speed at a 20 mm pebble's centre exceeds its tipping speed, at a Shields number of 0.055, against the pocket angle. At 54° it is 47 per cent, at 62° 36, at 70° 25; even an 80° pocket leaves it out 12 per cent of the time. Regimes and numbers

A gust that tips a grain proves too much

A grain on a stream bed sits below the mean speed that would tip it out of its pocket and still moves, because turbulent sweeps bring fast fluid down for moments at a time. Replacing the mean speed with the measured spread of speeds at the grain is the obvious repair to a single-grain threshold, and it fails in three directions at once. At Shields' own number a pebble in any pocket measured on a natural bed is tipped a quarter to a half of the time; the share tipped rises as the sixth power of the stress where Paintal's transport rose as the sixteenth; and the gusts lower a cobble's threshold twice as far as a fine sand's, widening the very gap they were expected to close.