Circulation and lift

A panel can live with a neighbour one panel away, except at the edge

A lumped-vortex panel is exact for any onset flow that varies linearly across it, and a neighbouring vortex makes the onset flow curve over a length equal to its distance. So the natural rule is that a panel should be no longer than the gap to the nearest neighbour, and beside the middle of a chord that rule is exactly right: the lift error depends on the gap over the panel length and on nothing else, a third of a per cent when the two are equal. Under the leading edge the rule fails, and the reason is the edge's own singularity rather than anything about the neighbour.

Worth reading first: One panel is exact, and every panel is wrong · Nothing but the edge.

One panel is exact, and every panel is wrong took the oldest trick in the panel methods — a vortex a quarter of the way along a panel, the flow condition imposed three quarters of the way along — and found that it is not an approximation that improves with refinement. It is exact, on one panel or on sixty-four, for any onset flow that varies linearly across each panel, and wrong in a way refinement cannot touch for anything else. Its sharpest test was the ground: a flat plate near the ground has an image vortex, and the image bends the onset flow across the chord. At a height of a fifth of a chord one panel read a lift 51 per cent too high.

That essay ended with a proposal. Any neighbour — the ground, a second element, a tunnel wall, the tip vortex of the blade ahead — makes the onset flow curve over a length roughly equal to its distance. If the panel method’s only failure is a curved onset flow, the error should depend only on how many panels fit into that length, and the panel count a problem needs could be stated in one line: no panel longer than the gap. This essay tests the proposal on the cleanest neighbour there is, a single free vortex beside a flat plate, where the exact answer is known for any position and any distance.

Beside mid-chord, the error is a function of the gap over the panel size and nothing else. The size of the lift error, panels against the exact linearised lift, for a flat plate with a free vortex under its mid-chord, against the vortex's distance from the plate divided by the panel length, for 8 to 128 panels. The five curves lie on one another: 8.7 per cent at half a panel, 0.38 per cent at one. The dip near two panels is where the error changes sign; past it the error is below a quarter of a per cent for every count from 8 up, and the curves part, because a gap of several panels is no longer small against the chord.
Fig. 1 The size of the lift error, panels against the exact linearised lift, for a flat plate with a free vortex under its mid-chord, against the vortex’s distance from the plate divided by the panel length, for 8 to 128 panels. The five curves lie on one another: 8.7 per cent at half a panel, 0.38 per cent at one. The dip near two panels is where the error changes sign; past it the error is below a quarter of a per cent for every count from 8 up, and the curves part, because a gap of several panels is no longer small against the chord.

The test, and its exact answer

The plate has unit chord and lies along the stream at no incidence. A free vortex of unit strength sits a distance dd below it at a position x0x_0 along the chord. Linearised, the plate’s job is to cancel the vortex’s velocity normal to it, which on the plate is

w(x)=−12π x−x0(x−x0)2+d2,w(x)=-\frac{1}{2\pi}\,\frac{x-x_0}{(x-x_0)^2+d^2},

a velocity that changes sign under the vortex and varies over a length dd. The exact lift of a thin section for any such ww is Glauert’s, Cl=π(2A0+A1)C_l=\pi(2A_0+A_1), with the AnA_n the cosine moments of ww in the angle θ\theta that maps the chord onto a half-circle. It needs no panels, only a quadrature in θ\theta fine enough to resolve a neighbour a few thousandths of a chord away, and two hundred thousand points do that.

The panel answer is the lumped-vortex method of the previous essay, with NN equal panels of length h=1/Nh=1/N. The two answers agree to a part in a million when both should — with the vortex ahead of the plate and 512 panels — so the quadrature and the panels are measuring the same thing, and the differences that follow are the method’s.

Beside mid-chord: one variable

With the vortex under the middle of the chord the proposal holds, and holds better than it had any right to. Plotted against the gap over the panel length, d/hd/h, the lift errors of 8, 16, 32, 64 and 128 panels fall on one curve. At half a panel the lift is 8.7 per cent too low on 128 panels and 9.2 per cent on 16; at one panel 0.38 and 0.41 per cent; between two and three panels the error changes sign, and past it it is a few hundredths of a per cent. Across 16 to 128 panels, at gaps of a half and one panel, the error moves by 7 per cent of itself. A panel method beside a neighbour is wrong by an amount set by how many panels fit in the gap, and not by how many there are in the chord.

The reason is the one the previous essay gave for the method’s exactness, run in reverse. A lumped vortex with its control point at three quarters is exact for an onset flow linear across its own panel. The neighbour’s flow is not linear across any panel whose length is comparable with the neighbour’s distance, and the departure from linearity across a panel of length hh at a distance dd is a function of h/dh/d alone — the curve has the same shape at every scale. Beside mid-chord the exact sheet is smooth, and nothing else on the plate has a scale of its own, so the error inherits that single variable. A neighbour a fifth of a chord away on eight panels and one a fiftieth of a chord away on eighty are, to the method, the same problem.

Panels next to the vortex take the wrong share, and the rest of the plate inherits the mistakeThe circulation on each of 16 panels against the converged sheet's circulation over the same stretch of chord, for a vortex under mid-chord 1 panel length away. The panels nearest the vortex are where they part; the lift comes out low by 0.41 per cent. Dialled through gaps of half a panel to four, the disagreement shrinks from the whole middle of the plate to nothing visible.00.20.40.60.81-0.3-0.25-0.2-0.15-0.1-0.050position along the chordcirculation on the panelconverged sheet, 512 panels summed16 panelsa flat plate of unit chord, linearised, beside a free unit vortex; N equal lumped-vortex panels, control points at three-quartersinviscid, steady, the vortex held fixed; exact lift from Glauert's integrals
Fig. 2 The circulation on each of 16 panels against the converged sheet’s circulation over the same stretch of chord, for a vortex under mid-chord one panel length away. The panels nearest the vortex are where they part; the lift comes out low by 0.41 per cent. Dialled through gaps of half a panel to four, the disagreement shrinks from the whole middle of the plate to nothing visible.

Where the error lives is just as local. The circulation each of 16 panels carries, set against the converged sheet’s circulation summed over the same stretch of chord, parts company only next to the vortex. At a gap of half a panel the two panels nearest the vortex take visibly wrong shares and the error spreads into their neighbours, because every panel’s strength is coupled to every other’s through the linear system; at a gap of one panel the disagreement is confined to the panels either side; at two and four it cannot be seen. That is the practical content of the collapse. A user who refines a whole section because one region is near a neighbour is spending panels where they do nothing; what a panel count controls is the local resolution, and only the local resolution near the neighbour needs to change.

What a coarse panel sees of a vortex

The sign of the error says what goes wrong. Beside mid-chord, with the panels coarse against the gap, the lift is too low, and by a lot: 9 per cent at half a panel, 40 per cent at a quarter. The vortex’s normal velocity on the plate is an antisymmetric pulse, upward on one side of it and downward on the other, each lobe about as wide as the gap. A panel whose control point falls inside one lobe and whose neighbour’s falls inside the other sees two large velocities of opposite sign, a long way apart in the panel’s terms, and solves for strengths that cancel each other more than the true sheet’s do. The pulse is resolved as something weaker than it is, and the plate carries less of the lift the vortex induces.

Between two and three panels per gap the sign turns over and the lift comes out very slightly high: the lobes are now resolved, and what is left is the ordinary second-order error of sampling a curved velocity at one point per panel, which here has the opposite sign. The zero crossing is why the dip in the first figure is sharp. It is not a sweet spot to aim for, since its position moves with where the vortex is; it is the boundary between a neighbour the panels cannot see and one they see slightly wrongly.

Under the leading edge: no collapse

Move the same vortex forward until it sits under the leading edge, and the same plot looks quite different.

Under the leading edge the same plot does not collapse: more panels keep helping at a fixed ratio. The same lift error with the vortex under the leading edge instead. At a gap of one panel the error is 0.63 per cent on 8 panels and 0.11 per cent on 128: it falls roughly as the panel length to the power 0.61. The sheet's square-root singularity at the edge is what a coarse panel cannot follow, and a neighbour beside the edge excites it.
Fig. 3 The same lift error with the vortex under the leading edge instead. At a gap of one panel the error is 0.63 per cent on 8 panels and 0.11 per cent on 128: it falls roughly as the panel length to the power 0.61. The sheet’s square-root singularity at the edge is what a coarse panel cannot follow, and a neighbour beside the edge excites it.

The curves no longer lie on one another. At a fixed ratio of gap to panel length, more panels keep helping: at one panel’s gap the error is 0.63 per cent on 8 panels, 0.38 on 16, 0.25 on 32, 0.17 on 64 and 0.11 on 128. A fit through them gives the error falling as the panel length to the power 0.61. In absolute terms the errors are smaller than beside mid-chord — at half a panel’s gap, under half a per cent rather than nine — but they belong to a different law, and that is what the proposal could not survive.

The difference is the edge. A flat plate’s exact vortex sheet is singular at its leading edge, growing as one over the square root of the distance from it; that singularity is what carries a finite force from an infinite speed, and nothing but the edge found it to be the one piece of information a panel method has to be given rather than computed. The lumped vortex represents the plate’s own singularity correctly when the onset flow is uniform — that is half of why it is exact — but the neighbour beside the edge changes how strongly the singular part is excited, by an amount that varies over the gap. The first panel then has to represent a square-root variation that the neighbour has made locally non-uniform, and a square root has a scale of its own: its structure at a distance hh from the edge is not a scaled copy of its structure at 2h2h in the way a smooth curve’s is. The measured slope, 0.61, is close to the one-half a square-root singularity would give if the leading panel’s error dominated. That interpretation is not proved here; the measurement is.

Ahead of the plate: an ordinary curve

The third position separates the two effects. Put the vortex a fifth of a chord ahead of the leading edge and a twentieth of a chord below the plate’s line, and the plate never has the vortex beside it at all.

A vortex ahead of the plate is an ordinary curved stream, and the error falls as the square of the panel. The size of the lift error against the number of panels for a vortex a fifth of a chord ahead of the leading edge and 0.05 chords below the plate's line. The error is 1.3 per cent on 4 panels and 3.54·10⁻⁴ per cent on 256, falling as the square of the panel length (a fitted slope of 2), and it does not depend on the gap: the plate sees a smoothly curved onset flow.
Fig. 4 The size of the lift error against the number of panels for a vortex a fifth of a chord ahead of the leading edge and 0.05 chords below the plate’s line. The error is 1.3 per cent on 4 panels and 3.5×10−43.5\times10^{-4} per cent on 256, falling as the square of the panel length (a fitted slope of 2), and it does not depend on the gap: the plate sees a smoothly curved onset flow.

Then the onset flow across the chord is smooth, curved on the scale of the chord rather than of the gap, and the error is the ordinary error of a second-order method: 1.3 per cent on four panels, falling by four each time the count doubles, to a few parts in a million on 256. It hardly depends on the gap at all. The fitted slope is 2.00. This is the error the previous essay’s ground figure was measuring at heights above a chord: a gently curved onset that refinement removes in the usual way.

So the three positions are three different regimes. Ahead of the plate, the neighbour is a curved stream and the error is second-order in the panel length. Beside the smooth part of the chord, the neighbour sets a local length and the error is a function of that length over the panel’s. Beside the edge, the neighbour couples into the singularity and the error has a scale of its own.

The rule, in panels per gap

For one per cent beside the chord, make the panels no longer than the gap. The smallest power-of-two panel count that brings the lift error under one per cent, against the vortex's distance from the plate in chords: under mid-chord it is 256, 128, 64, 32, 16, 8, 2 for gaps of 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.4, close to one panel per gap; under the leading edge one per cent is easier, but a tenth of a per cent needs 256, 128, 128, 64, 32, 16, 16.
Fig. 5 The smallest power-of-two panel count that brings the lift error under one per cent, against the vortex’s distance from the plate in chords: under mid-chord it is 256, 128, 64, 32, 16, 8, 2 for gaps of 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.4, close to one panel per gap; under the leading edge one per cent is easier, but a tenth of a per cent needs 256, 128, 128, 64, 32, 16, 16.

As a rule of thumb for the smooth part of a section, the collapse turns into a single sentence: for one per cent in lift, make the panels near a neighbour no longer than the gap to it. The counts needed beside mid-chord are 256, 128, 64, 32, 16 and 8 for gaps of 0.005 to 0.2 chords — one panel per gap, within the factor of two that power-of-two counts allow. A tenth of a per cent needs about twice that. Under the leading edge one per cent comes more cheaply, because the absolute error there is smaller, but every further factor of ten in accuracy costs much more than a factor of two in panels, because the error falls only as the panel length to the power 0.6; a tenth of a per cent needs 256 panels at a gap of 0.005 and still 16 at a gap of 0.4.

That is the case that matters in practice. The neighbours that come close to a section’s leading edge are the dangerous ones: the tip vortex a helicopter blade flies through in descent strikes it near the leading edge, a slat’s trailing edge sits just ahead of and above the main element’s nose, and the flow round a slotted section is decided there. Each of these is the case where the one-line rule is not enough.

What the panels are being asked

The surprise in this is where the difficulty lies. The intuitive account says a panel method fails near a neighbour because the neighbour’s field is strong and steep, and puts the worst case directly under the vortex. That is where the error is largest at a given panel count, but it is the easy case: the error there is a function of one variable and any user can be told how to remove it. The hard case is a weaker effect at the edge, where a panel method already has its one non-local piece of information, the Kutta condition’s partner at the other end of the chord. The neighbour beside the edge is hard not because it is close, but because it is close to the one place the method is already working at its limit.

The same structure is behind the cushion that is there after all: the ground’s image spreads along the whole chord, beside the edge as well as the middle, which is why the single panel there overstated the lift so badly. And a foil under the surface has an image of the opposite sign that does the same thing from above.

The convention the numbers are in

The plate has unit chord; the vortex has unit strength; the onset stream has unit speed; lift coefficients are per unit of Γ/(Uc)\Gamma/(Uc). Errors are relative to the exact linearised lift for the same vortex position. Panels are equal, with the vortex at a quarter and the control point at three quarters of each, and the gap dd is the vortex’s distance from the line of the plate. The problem is linearised: the plate’s boundary condition is applied on y=0y=0, the vortex is held fixed, and the lift is the circulation’s Kutta–Joukowski force with no nonlinear interaction between the vortex and the bound sheet.

What the picture cannot show

The vortex is held fixed and the problem is steady. A real neighbouring vortex moves under the plate’s influence, and a blade meeting a tip vortex does so in an unsteady flow where the lift arrives late; a panel method for that case also has to shed a wake, and the wake’s panels have their own resolution requirement near the trailing edge. The plate is flat; a thick section’s leading edge has a finite radius and no singularity, and on it the leading-edge regime should give way to the mid-chord one once the panels are finer than the radius. Equal panels were used deliberately, since they are what the rule is about; cosine spacing, which crowds panels at the edges, is the standard remedy for the edge and was not tested here.

What could have disagreed

A plate beside a vortex: the checks. The exact lift against 512 panels where both should agree, the spread of the collapse beside mid-chord, the leading edge's failure to collapse, and the second order upstream.
Fig. 6 The exact lift against 512 panels where both should agree, the spread of the collapse beside mid-chord, the leading edge’s failure to collapse, and the second order upstream.

The collapse could have failed beside mid-chord as well, which would have meant the error depended on the chord’s own scale, and it did not, to within 7 per cent of itself across a factor of eight in panel count. The upstream case could have shown a slope other than two, which would have meant the method was not second order for smooth onsets; it showed 2.00. And the leading-edge case could have collapsed, which would have made the rule universal. It was the third that disagreed. The ledger carries the four numbers: the exact and panel lifts agreeing to a part in a million for a neighbour ahead of the plate, the collapse’s spread of 7 per cent beside mid-chord, the leading-edge error falling from 0.38 to 0.11 per cent between 16 and 128 panels at the same ratio of gap to panel, and the two slopes, 0.61 and 2.00.

Who found it, and when

The lumped vortex with the three-quarter-chord control point is Pistolesi’s of 1937, its exactness for equal panels James’s of 1972. Glauert’s series for the thin aerofoil dates from 1926. The difficulty at the leading edge is old: Lan’s quasi-vortex-lattice method of 1974 placed its vortices and control points by a cosine rule precisely so that the sum would behave like Glauert’s integral near the edges, and recovered the leading-edge suction that equal panels lose.

Still open: whether cosine spacing restores the collapse at the edge

The leading-edge case failed to collapse because the panels there are asked to represent a square root on a uniform mesh. Lan’s spacing puts panel edges at the cosine points of the chord, so the panels are short near the edge in exactly the proportion the square root needs. The next calculation repeats the leading-edge measurement on cosine-spaced panels, with the gap measured against the length of the panel nearest the vortex, and asks whether the curves then collapse as they do beside mid-chord — which would make the one-line rule universal once the spacing is right — or whether a neighbour near the edge still has a scale of its own that no spacing removes.

What links here

Computed from the collection rather than written here: the essays that point at this one.

Reads more easily once this is understood

Essays that name this one as worth reading first.

Shares its objects with

Essays naming at least two of the same things, that neither author linked.

Named objects

A dashed tag is an object no other essay names yet.

ConvergenceDiscretisationKutta conditionLift coefficientModel limitPanel methodThin-aerofoil theoryVortex sheet