One panel is exact, and every panel is wrong
Worth reading first: Nothing but the edge · Three numbers out of a camber line.
A numerical method normally earns its result by refinement. Double the grid, watch the answer settle, extrapolate if there’s time. The panel method behaves that way: sixty-four panels are better than sixteen, and a careful reader checks the trend. So it’s disorienting to find that one of the oldest discretisations in aerodynamics doesn’t converge at all, in a precise sense. It has nowhere to go, because it’s already there.
The construction is close to a joke. Replace a flat plate at incidence with one point vortex at its quarter chord. Require the flow to be tangent to the plate at one point, its three-quarter chord. That gives one equation for one unknown, and its solution is a few lines:
That’s the exact lift. It isn’t near it. It’s the number that the whole of thin-aerofoil theory produces from a singular integral equation, using a device that doesn’t look capable of containing it. Now cut the plate into two panels, put a vortex at each panel’s quarter, a control point at each panel’s three-quarter, solve the system and add up. It’s again . Cut it into sixty-four: to the last digit the arithmetic can hold.
The result has a name, Pistolesi’s rule, from 1937, and it’s used constantly, including in several essays here. It’s rarely asked what exactly is being claimed. The interesting part is what it does not deliver, and this essay goes through that: the same calculation that has the exact total gets every part of it wrong, and it’s that mismatch which says what kind of exactness this is.
Refinement does nothing, in either direction
The figure above is the argument, and it’s stronger than the usual statement of the rule. Move the control point to any fraction of the panel and the lift is
for one panel, which is a two-line calculation, and for every other panel count as well, which isn’t. That was verified here numerically over counts from one to sixty-four, and the result was proved in general by James in 1972. So with a control point at the lift is ten per cent low on one panel, and ten per cent low on a thousand. A student who takes the common view that a slightly wrong placement refines away is mistaken: the error isn’t truncation at all, it’s the coefficient of a line.
So there are two rather different things hiding in the word “converge”. A discretisation has a discretisation error, and that does get smaller. This discretisation has none for this quantity, or it has the same fixed one at every count, depending on . Nothing is being approached. What the panel count controls is something else.
What the panel count controls
To see what, compare panels with the true sheet. The exact flat-plate vorticity is , and its integral over a stretch of chord is known in closed form. So each lumped vortex can be held against the exact circulation on the same stretch.
They don’t match anywhere. The first panel is low and the last is high, and the middle ones cross over. A lumped vortex isn’t the integral of the sheet over its panel, and there’s no reason it should be, since it’s placed at a quarter-panel and not at the centre of vorticity. On four panels, the figures are 1.718, 0.736, 0.442, 0.245 against 1.913, 0.658, 0.390, 0.181. On sixteen the first is 0.879 against 0.990. Refining doesn’t cure the first panel, either: its error is about eleven per cent whatever the count, because near the leading edge the sheet is singular and a uniform grid never resolves it.
So here’s the first statement of what’s going on. The system has the correct total by a cancellation among parts that are each wrong. That’s unusual and it’s an instructive thing to see, since a total assembled from wrong parts is what a thoughtful reviewer normally rejects. A calculation can pass a check on the sum and fail any check on an individual value.
The other side of it is what a user should actually do. If the purpose is a lift coefficient on a flat plate, one panel is enough. If it’s the pressure at a station, then the lumped-vortex result isn’t the pressure at all until refined and interpreted, and the panel method of the earlier essay, with its distributed singularities, is doing a different job. It’s worth remembering how much of the field uses this rule for a force and only a force: the delayed lift of an impulsive start, a foil below the free surface, and a two-plate biplane all lean on it.
Why three-quarters
The most direct argument is a calculation of what a vortex at the quarter chord can see, and it’s about curvature. Suppose the onset flow isn’t uniform but varies linearly along the chord, as it does for a parabolic camber line. For an exact thin section, as the three numbers out of a camber line showed, lift comes from a weighted average of the camber slope, with weight over the angle where . For a slope :
Now substitute a slope that’s linear in : . The integral comes out as , so . It’s just times the slope at the three-quarter chord. That’s the rule, and it’s a statement about one weight function: the first moment of Glauert’s lift weight is at three-quarters. Any linear distribution of downwash can be evaluated there, and a uniform or a parabolic section is exact for that reason. It says nothing about stations, nothing about pressure, and nothing about a higher moment. It’s a quadrature rule, and a one-point one, for a specific integral.
That reading tells what must come next. A one-point rule that integrates linear functions exactly, with a nonlinear weight, can’t be expected to do a cubic slope. And if the same weight is integrated with a different kernel, as for the moment rather than the lift, the point isn’t the right one any more.
The parabola’s moment, and a reflexed line with the wrong sign
Both predictions are correct, in order.
A vortex at a quarter of the chord has no arm about the quarter chord. So one panel reports zero moment for any section at all, regardless of camber, and on a parabola, which really has a moment of times its camber, that’s total failure on the same calculation that has the lift exact. With more panels the moment arrives at second order, which is an ordinary convergence. So the rule’s exactness is only on the lift. A panel method user who validates on lift can have a moment that’s wrong by anything.
That reflexed line is a good test case because the error isn’t small. The mean line has reflex toward the trailing edge, with slope changing sign along the chord, and a single control point at three-quarters sits on the wrong part of that curve. The result isn’t a modest under-prediction but lift of the wrong sign. Two panels gets the sign right and the size to within a half. By sixteen panels, it’s ordinary and comfortable.
Here’s a sharp way to state what makes the plate and the parabola special. They have a downwash no worse than linear along the chord, so a one-point rule can capture them. A slope that’s cubic along the chord can’t be integrated by a one-point quadrature; but with panels, the rule is applied piecewise, and each panel again sees something nearly linear. So convergence appears as soon as there’s anything to converge to. The plate has nothing, which is the paradox the essay opened with: a flat plate is too simple a problem for the refinement to have any work to do.
The ground, which has curvature nobody put there
Most users think of that as a limit on the section’s camber, and they’d be surprised to learn it’s about the flow. A flat plate near the ground has no camber. It has an image vortex, though, and an image bends the onset velocity across the chord as a flow past a curved section would. So a flat plate in a curved stream is, by the argument above, no longer inside the rule.
That’s a useful limit to have in numbers. A single lumped vortex is an excellent device above a chord of height and it’s badly wrong below a third of a chord. The figure has one more thing to say, because the converged curve itself is above one: the cushion is real in plane flow at any height. One panel simply overdoes it, because a single image at a single distance overstates the near part of a field that is spread over the chord in reality.
So anything that moves a neighbour close, whether the ground, a second element or a tunnel wall, puts the rule outside its assumption of a nearly-linear onset flow, and the panel count starts to matter. One panel is exact only for a section in a stream that’s uniform or varies linearly. It’s correct for a plate in empty space, and any added detail needs panels. That’s a clean way to decide how many are wanted. Ask how quickly the onset flow varies across a chord and take enough panels to make it linear over each.
The worst test case in the subject
There’s a practical warning in all this, and it applies to anyone who has written a vortex-lattice calculation or inherited one. The first thing most people do with a new lifting solver is run a flat plate and check the answer against . It’s the obvious check. There’s a textbook number and a clean geometry, and a result of 6.283 looks like proof the solver works.
This essay’s arithmetic says how little that proves. A flat plate returns at one panel, so it says nothing about convergence, since none is occurring. It returns whatever the panel strengths are doing, so it can’t detect a wrong distribution. It reports the same answer for the moment about the quarter chord whether or not the solver has anything right about arms, because that moment is zero in both. What it does test is the location of the control point within the panel, where a mistake shows up immediately: a solver with its control points at the panel centre returns half the lift, whatever the count, and returns it steadily. That’s a useful bug to catch, but it’s the only one on the list.
A much better first test costs nothing extra. Run a mean line with a slope that isn’t linear along the chord, compare the lift and the moment against Glauert’s coefficients, and double the panels twice. On the reflexed line used above, four panels give 8.25 against 9.42, eight give 9.13, and sixteen give 9.35, and the moment goes , , against . The error falls by a factor of four at each doubling, which is what a healthy second-order method looks like. A solver with an error in it would either stop improving or improve at a different rate. The plate could never have said that.
The general moral is a familiar one with a sharper edge than usual. A check against an exact answer is only as good as the set of errors that could have changed the answer. In this case the exact answer is exact for the wrong reason, and that reason removes nearly all those errors from view. The remedy is the one that applies to any check: pick the test case in which the mistake being looked for has somewhere to show.
The surprising company it keeps
The rule’s explanation, as a quadrature for a weighted integral, ties it to something from outside aerodynamics, and this is the connection worth carrying. Gaussian quadrature picks its points as zeros of orthogonal polynomials, so that points integrate exactly a polynomial of degree with some weight. In the thin-aerofoil problem the singular Cauchy kernel with the Kutta condition has a corresponding structure, and the choice of vortex and control points as a pair of interlaced Chebyshev points gives results that are exact for polynomials of much higher degree than equal spacing can manage. That’s what Lan’s quasi-vortex-lattice method of 1974 does explicitly: it gets moment and lift to high accuracy with few panels by placing them at Chebyshev points. The quarter-three-quarter pair is the one-point member of a family, and it’s a family that the computational mathematician would recognise at once.
There’s another way of saying the same thing, closer to how many conditions a flow has to be told. The offset of a quarter-chord between vortex and control point is what encodes the Kutta condition in a system that has no explicit row for it. In the panel method of the earlier essay, the missing row had to be stated; here it’s built in by making the system square with an offset, so the trailing-edge singularity is removed by location, not by equation. A method can state a physical requirement as a row or as a placement, and the two don’t look alike.
What the discretisation cannot show
Pressure, station by station. Nothing here gives the true pressure on a panel. The panel strengths differ from the sheet’s integrals, and they’d need interpretation before they could be read as a load. The leading-edge singularity is never resolved at all.
Leading-edge suction. The lift’s exactness is on the normal force at small incidence. A real plate gets its thrust from the suction at its leading edge, and a sum of point vortices gets that only through separate reasoning.
Thickness and viscosity. No thickness and no boundary layer appear, as usual for thin-section theory; on a real section with a real layer, the itself isn’t reached, and the exactness of a rule doesn’t help.
Why the grid doesn’t matter. Most of the argument above is put for equal panels, because James’s theorem was, and the quadrature reading explains one panel rather than many. In fact a cosine grid with the same quarter and three-quarter points also returned to rounding at two, four, eight, sixteen and sixty-four panels when tried here. So the total’s exactness isn’t a property of equal spacing, and the figures don’t show why it survives a change of spacing. That’s a gap in the explanation, and it’s left open.
The convention
Chord one. Downwash is positive downward at unit stream, so incidence is and a camber line’s contribution is . Vortices at , control points at , , with unless a figure says otherwise. Lift and moment coefficients are on chord, with the moment about the quarter chord, positive nose-up. The parabolic arc is and the reflexed line has slope proportional to , scaled so that its figures are readable; only ratios to its exact lift matter. Exact values use the Glauert coefficients, by a 40,000-point quadrature in .
What could have disagreed
The Glauert integral is a separate route from the linear solve and it’s the one the rule is tested against. The closed form for one panel is a separate route again. The calculation refuses a panel count of zero, a control point at or ahead of the vortex, where the kernel has the wrong sign or diverges, and an unknown section.
Pistolesi, James, Lan
Pistolesi’s rule dates from 1937. Weissinger’s lifting-surface method of 1947 used the same pair as the basis for an influential approximation, and it spread into vortex-lattice codes through the 1960s. The theorem that the lift is exact for every equal-panel count is due to James, in a 1972 paper on the mathematics of discrete vortex methods. Lan’s quasi-vortex-lattice method, with Chebyshev placement, followed in 1974. Glauert’s coefficients are from 1926.
Still open: how close a neighbour a panel can live with
The ground figure measures one panel’s failure against one kind of neighbour. The next calculation would make that into a rule: for a section with a neighbouring vortex at a distance , compute the error in lift against and for panels of a chord over , and ask whether the error collapses on the single variable with the panel size. If it does, the panel count a tandem, a slot or a ground problem needs can be stated in one line, and a user would know how close is too close before starting; if it doesn’t, there’s an effect beyond the local curvature of the onset flow that these figures have not identified.
What links here
Computed from the collection rather than written here: the essays that point at this one.
Reads more easily once this is understood
Essays that name this one as worth reading first.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- A jet flap is a flap made of the jet — both name kutta condition, lift coefficient, model limit, thin-aerofoil theory, vortex sheet
- A load carried to the trailing edge needs a hook — both name kutta condition, model limit, thin-aerofoil theory
- A NACA section multiplies its lift by nearly one plus its thickness, and a nose correction cannot supply it — both name model limit, panel method, thin-aerofoil theory
- A sheet that cannot stay a sheet — both name discretisation, model limit, vortex sheet
- No elevon reaches past a quarter chord — both name lift coefficient, model limit, thin-aerofoil theory
- The condition that can be bought — both name kutta condition, lift coefficient, model limit
Named objects
A dashed tag is an object no other essay names yet.
ConvergenceDiscretisationKutta conditionLift coefficientModel limitPanel methodThin-aerofoil theoryVortex sheet