Circulation and lift

One panel is exact, and every panel is wrong

Put one vortex a quarter of the way along a flat plate, satisfy the flow at one point three-quarters of the way along, and the lift comes out as exactly 2 pi. Cut the plate into sixty-four panels and it is still exactly 2 pi, not closer to it. Yet no panel's strength matches the true sheet on that panel, a parabola's moment is absent on one panel, and a reflexed mean line gets the wrong sign. Pistolesi's rule is not an approximation that converges. It is an exact statement about one integral and nothing else.

Worth reading first: Nothing but the edge · Three numbers out of a camber line.

A numerical method normally earns its result by refinement. Double the grid, watch the answer settle, extrapolate if there’s time. The panel method behaves that way: sixty-four panels are better than sixteen, and a careful reader checks the trend. So it’s disorienting to find that one of the oldest discretisations in aerodynamics doesn’t converge at all, in a precise sense. It has nowhere to go, because it’s already there.

The construction is close to a joke. Replace a flat plate at incidence with one point vortex at its quarter chord. Require the flow to be tangent to the plate at one point, its three-quarter chord. That gives one equation for one unknown, and its solution is a few lines:

Γ2π⋅12c=Uα⟹Γ=πcUα⟹Cl=2ΓUc=2πα.\frac{\Gamma}{2\pi\cdot\tfrac12 c}=U\alpha \quad\Longrightarrow\quad \Gamma=\pi cU\alpha \quad\Longrightarrow\quad C_l=\frac{2\Gamma}{Uc}=2\pi\alpha .

That’s the exact lift. It isn’t near it. It’s the number that the whole of thin-aerofoil theory produces from a singular integral equation, using a device that doesn’t look capable of containing it. Now cut the plate into two panels, put a vortex at each panel’s quarter, a control point at each panel’s three-quarter, solve the 2×22\times2 system and add up. It’s again 2πα2\pi\alpha. Cut it into sixty-four: 2πα2\pi\alpha to the last digit the arithmetic can hold.

The result has a name, Pistolesi’s rule, from 1937, and it’s used constantly, including in several essays here. It’s rarely asked what exactly is being claimed. The interesting part is what it does not deliver, and this essay goes through that: the same calculation that has the exact total gets every part of it wrong, and it’s that mismatch which says what kind of exactness this is.

The lift is a straight line in where the control point sits, and it passes through one at three-quartersThe lift of a flat plate on 1 equal panels over the exact 2π per radian, against the control point's position within each panel. It is 2(f − 1/4) at every panel count: 0.3 at 0.4, 0.6 at 0.55, 0.9 at 0.7, 1.2 at 0.85.three-quartersexact0.40.50.60.70.80.900.20.40.60.811.21.41.6control point's position within a panellift over exact lift1 panelsa thin section as N point vortices, linearised ideal flow, a chord cut into equal panelsattached, inviscid, the smooth-edge condition at the trailing edge
Fig. 1 The lift of a flat plate over the exact 2πα2\pi\alpha, against where the control point sits within each panel. It’s a straight line, 2(f−14)2(f-\tfrac14), and it passes through one at three-quarters. Dialled from one panel to two, four and sixteen, the line does not move.

Refinement does nothing, in either direction

The figure above is the argument, and it’s stronger than the usual statement of the rule. Move the control point to any fraction ff of the panel and the lift is

Cl2πα=2(f−14)\frac{C_l}{2\pi\alpha}=2\left(f-\tfrac14\right)

for one panel, which is a two-line calculation, and for every other panel count as well, which isn’t. That was verified here numerically over counts from one to sixty-four, and the result was proved in general by James in 1972. So with a control point at f=0.7f=0.7 the lift is ten per cent low on one panel, and ten per cent low on a thousand. A student who takes the common view that a slightly wrong placement refines away is mistaken: the error isn’t truncation at all, it’s the coefficient of a line.

So there are two rather different things hiding in the word “converge”. A discretisation has a discretisation error, and that does get smaller. This discretisation has none for this quantity, or it has the same fixed one at every count, depending on ff. Nothing is being approached. What the panel count controls is something else.

What the panel count controls

To see what, compare panels with the true sheet. The exact flat-plate vorticity is γ(x)=2Uα(1−x)/x\gamma(x)=2U\alpha\sqrt{(1-x)/x}, and its integral over a stretch of chord is known in closed form. So each lumped vortex can be held against the exact circulation on the same stretch.

Every panel's strength is wrong and they add up to exactly the right total. On eight panels, each vortex's strength at unit incidence beside the exact sheet's integral over the same panel: first panel 1.23 against 1.38, last 0.0823 against 0.0613. Their sums are both π, to the rounding of the arithmetic.
Fig. 2 On eight panels at unit incidence, each panel’s strength beside the exact sheet’s integral over that panel. The first is 1.23 against 1.38, which is eleven per cent low, and the last 0.0823 against 0.0613, a third high. The two sets of points add to the same total, π\pi.

They don’t match anywhere. The first panel is low and the last is high, and the middle ones cross over. A lumped vortex isn’t the integral of the sheet over its panel, and there’s no reason it should be, since it’s placed at a quarter-panel and not at the centre of vorticity. On four panels, the figures are 1.718, 0.736, 0.442, 0.245 against 1.913, 0.658, 0.390, 0.181. On sixteen the first is 0.879 against 0.990. Refining doesn’t cure the first panel, either: its error is about eleven per cent whatever the count, because near the leading edge the sheet is singular and a uniform grid never resolves it.

So here’s the first statement of what’s going on. The system has the correct total by a cancellation among parts that are each wrong. That’s unusual and it’s an instructive thing to see, since a total assembled from wrong parts is what a thoughtful reviewer normally rejects. A calculation can pass a check on the sum and fail any check on an individual value.

The other side of it is what a user should actually do. If the purpose is a lift coefficient on a flat plate, one panel is enough. If it’s the pressure at a station, then the lumped-vortex result isn’t the pressure at all until refined and interpreted, and the panel method of the earlier essay, with its distributed singularities, is doing a different job. It’s worth remembering how much of the field uses this rule for a force and only a force: the delayed lift of an impulsive start, a foil below the free surface, and a two-plate biplane all lean on it.

Why three-quarters

The most direct argument is a calculation of what a vortex at the quarter chord can see, and it’s about curvature. Suppose the onset flow isn’t uniform but varies linearly along the chord, as it does for a parabolic camber line. For an exact thin section, as the three numbers out of a camber line showed, lift comes from a weighted average of the camber slope, with weight (1−cos⁡θ)(1-\cos\theta) over the angle θ\theta where x=12(1−cos⁡θ)x=\tfrac12(1-\cos\theta). For a slope w(x)w(x):

Cl=2∫0πw(x(θ))(1−cos⁡θ) dθ.C_l=2\int_0^\pi w\bigl(x(\theta)\bigr)(1-\cos\theta)\,d\theta .

Now substitute a slope that’s linear in xx: w=a+bxw=a+bx. The integral comes out as 2πa+32πb2\pi a+\tfrac{3}{2}\pi b, so Cl=2π(a+34b)C_l=2\pi(a+\tfrac34 b). It’s just 2π2\pi times the slope at the three-quarter chord. That’s the rule, and it’s a statement about one weight function: the first moment of Glauert’s lift weight is at three-quarters. Any linear distribution of downwash can be evaluated there, and a uniform or a parabolic section is exact for that reason. It says nothing about stations, nothing about pressure, and nothing about a higher moment. It’s a quadrature rule, and a one-point one, for a specific integral.

That reading tells what must come next. A one-point rule that integrates linear functions exactly, with a nonlinear weight, can’t be expected to do a cubic slope. And if the same weight is integrated with a different kernel, as for the moment rather than the lift, the point isn’t the right one any more.

The parabola’s moment, and a reflexed line with the wrong sign

Both predictions are correct, in order.

A parabola's lift is exact on one panel and its moment takes a refinement to arrive. The relative error in the quarter-chord moment of a parabolic arc against panel count. One panel has no arm and reports no moment at all, an error of 1; two panels are 0.25 out, four 0.0625, eight 0.0156, falling by four each time the count doubles.
Fig. 3 The relative error in the quarter-chord moment of a parabolic arc against panel count: one panel reports no moment at all, an error of 1; two are 0.25 out, four 0.0625, eight 0.0156. Each doubling takes off a factor of four.

A vortex at a quarter of the chord has no arm about the quarter chord. So one panel reports zero moment for any section at all, regardless of camber, and on a parabola, which really has a moment of −π-\pi times its camber, that’s total failure on the same calculation that has the lift exact. With more panels the moment arrives at second order, which is an ordinary convergence. So the rule’s exactness is only on the lift. A panel method user who validates on lift can have a moment that’s wrong by anything.

The rule buys exactness only as far as a parabola, and a reflexed line has to refine like anything else. The relative error in lift against panel count. A plate and a parabolic arc sit at rounding error from one panel up. A reflexed mean line, whose slope is a cubic, with a lift of 9.42 per unit, is 2 out on one panel, which reverses its sign, then 0.5 on two and 0.125 on four, and falls as the square of the panel size after that.
Fig. 4 The relative error in lift against panel count. The plate and parabolic arc sit at rounding error from one panel up. A reflexed mean line, whose slope is a cubic, with an exact lift of 9.42 at this scale, is out by a factor of 2 on one panel because the single value has the opposite sign; it’s 0.5 out on two, 0.125 on four, and falls with the square of the panel size.

That reflexed line is a good test case because the error isn’t small. The mean line has reflex toward the trailing edge, with slope changing sign along the chord, and a single control point at three-quarters sits on the wrong part of that curve. The result isn’t a modest under-prediction but lift of the wrong sign. Two panels gets the sign right and the size to within a half. By sixteen panels, it’s ordinary and comfortable.

Here’s a sharp way to state what makes the plate and the parabola special. They have a downwash no worse than linear along the chord, so a one-point rule can capture them. A slope that’s cubic along the chord can’t be integrated by a one-point quadrature; but with NN panels, the rule is applied piecewise, and each panel again sees something nearly linear. So convergence appears as soon as there’s anything to converge to. The plate has nothing, which is the paradox the essay opened with: a flat plate is too simple a problem for the refinement to have any work to do.

The ground, which has curvature nobody put there

Most users think of that as a limit on the section’s camber, and they’d be surprised to learn it’s about the flow. A flat plate near the ground has no camber. It has an image vortex, though, and an image bends the onset velocity across the chord as a flow past a curved section would. So a flat plate in a curved stream is, by the argument above, no longer inside the rule.

Near the ground the onset flow bends faster than a parabola, and one panel is no longer enough. A plate's lift over its free value against height above the ground in chords, with the ground supplied by an image, for one panel, four and sixty-four. At a height of 0.2 chords one panel reads 2.56 and sixty-four read 1.69, so the error is 51 per cent. Above a chord they are within half a per cent of each other.
Fig. 5 A plate’s lift over its free-air value against height above the ground in chords, with the ground as an image, for one panel, four and sixty-four. At a height of 0.2 chords one panel reads 2.56 and sixty-four read 1.69, which is 51 per cent too high. Above a chord all three lie within half a per cent of each other.

That’s a useful limit to have in numbers. A single lumped vortex is an excellent device above a chord of height and it’s badly wrong below a third of a chord. The figure has one more thing to say, because the converged curve itself is above one: the cushion is real in plane flow at any height. One panel simply overdoes it, because a single image at a single distance overstates the near part of a field that is spread over the chord in reality.

So anything that moves a neighbour close, whether the ground, a second element or a tunnel wall, puts the rule outside its assumption of a nearly-linear onset flow, and the panel count starts to matter. One panel is exact only for a section in a stream that’s uniform or varies linearly. It’s correct for a plate in empty space, and any added detail needs panels. That’s a clean way to decide how many are wanted. Ask how quickly the onset flow varies across a chord and take enough panels to make it linear over each.

The worst test case in the subject

There’s a practical warning in all this, and it applies to anyone who has written a vortex-lattice calculation or inherited one. The first thing most people do with a new lifting solver is run a flat plate and check the answer against 2π2\pi. It’s the obvious check. There’s a textbook number and a clean geometry, and a result of 6.283 looks like proof the solver works.

This essay’s arithmetic says how little that proves. A flat plate returns 2π2\pi at one panel, so it says nothing about convergence, since none is occurring. It returns 2π2\pi whatever the panel strengths are doing, so it can’t detect a wrong distribution. It reports the same answer for the moment about the quarter chord whether or not the solver has anything right about arms, because that moment is zero in both. What it does test is the location of the control point within the panel, where a mistake shows up immediately: a solver with its control points at the panel centre returns half the lift, whatever the count, and returns it steadily. That’s a useful bug to catch, but it’s the only one on the list.

A much better first test costs nothing extra. Run a mean line with a slope that isn’t linear along the chord, compare the lift and the moment against Glauert’s coefficients, and double the panels twice. On the reflexed line used above, four panels give 8.25 against 9.42, eight give 9.13, and sixteen give 9.35, and the moment goes −1.52-1.52, −2.14-2.14, −2.30-2.30 against −2.36-2.36. The error falls by a factor of four at each doubling, which is what a healthy second-order method looks like. A solver with an error in it would either stop improving or improve at a different rate. The plate could never have said that.

The general moral is a familiar one with a sharper edge than usual. A check against an exact answer is only as good as the set of errors that could have changed the answer. In this case the exact answer is exact for the wrong reason, and that reason removes nearly all those errors from view. The remedy is the one that applies to any check: pick the test case in which the mistake being looked for has somewhere to show.

The surprising company it keeps

The rule’s explanation, as a quadrature for a weighted integral, ties it to something from outside aerodynamics, and this is the connection worth carrying. Gaussian quadrature picks its points as zeros of orthogonal polynomials, so that NN points integrate exactly a polynomial of degree 2N−12N-1 with some weight. In the thin-aerofoil problem the singular Cauchy kernel with the Kutta condition has a corresponding structure, and the choice of vortex and control points as a pair of interlaced Chebyshev points gives results that are exact for polynomials of much higher degree than equal spacing can manage. That’s what Lan’s quasi-vortex-lattice method of 1974 does explicitly: it gets moment and lift to high accuracy with few panels by placing them at Chebyshev points. The quarter-three-quarter pair is the one-point member of a family, and it’s a family that the computational mathematician would recognise at once.

There’s another way of saying the same thing, closer to how many conditions a flow has to be told. The offset of a quarter-chord between vortex and control point is what encodes the Kutta condition in a system that has no explicit row for it. In the panel method of the earlier essay, the missing row had to be stated; here it’s built in by making the system square with an offset, so the trailing-edge singularity is removed by location, not by equation. A method can state a physical requirement as a row or as a placement, and the two don’t look alike.

What the discretisation cannot show

Pressure, station by station. Nothing here gives the true pressure on a panel. The panel strengths differ from the sheet’s integrals, and they’d need interpretation before they could be read as a load. The leading-edge singularity is never resolved at all.

Leading-edge suction. The lift’s exactness is on the normal force at small incidence. A real plate gets its thrust from the suction at its leading edge, and a sum of point vortices gets that only through separate reasoning.

Thickness and viscosity. No thickness and no boundary layer appear, as usual for thin-section theory; on a real section with a real layer, the 2π2\pi itself isn’t reached, and the exactness of a rule doesn’t help.

Why the grid doesn’t matter. Most of the argument above is put for equal panels, because James’s theorem was, and the quadrature reading explains one panel rather than many. In fact a cosine grid with the same quarter and three-quarter points also returned 2π2\pi to rounding at two, four, eight, sixteen and sixty-four panels when tried here. So the total’s exactness isn’t a property of equal spacing, and the figures don’t show why it survives a change of spacing. That’s a gap in the explanation, and it’s left open.

The convention

Chord one. Downwash ww is positive downward at unit stream, so incidence is w=αw=\alpha and a camber line’s contribution is −dz/dx-dz/dx. Vortices at (i+14)h(i+\tfrac14)h, control points at (i+f)h(i+f)h, h=1/Nh=1/N, with f=34f=\tfrac34 unless a figure says otherwise. Lift and moment coefficients are on chord, with the moment about the quarter chord, positive nose-up. The parabolic arc is z=4x(1−x)z=4x(1-x) and the reflexed line has slope proportional to (x−12)(8(x−12)2−1)(x-\tfrac12)(8(x-\tfrac12)^2-1), scaled so that its figures are readable; only ratios to its exact lift matter. Exact values use the Glauert coefficients, by a 40,000-point quadrature in θ\theta.

What could have disagreed

The lumped-vortex rule's numbers, and the checks on them. A plate's largest lift error across six panel counts; a parabolic arc on one panel against Glauert's integral; the closed form for one panel.
Fig. 6 A flat plate’s largest lift error across six panel counts from 1 to 40, at the rounding level of the arithmetic; a parabolic arc’s one-panel lift against Glauert’s integral, again rounding; and the closed form for one panel at three-quarters, one.

The Glauert integral is a separate route from the linear solve and it’s the one the rule is tested against. The closed form for one panel is a separate route again. The calculation refuses a panel count of zero, a control point at or ahead of the vortex, where the kernel has the wrong sign or diverges, and an unknown section.

Pistolesi, James, Lan

Pistolesi’s rule dates from 1937. Weissinger’s lifting-surface method of 1947 used the same pair as the basis for an influential approximation, and it spread into vortex-lattice codes through the 1960s. The theorem that the lift is exact for every equal-panel count is due to James, in a 1972 paper on the mathematics of discrete vortex methods. Lan’s quasi-vortex-lattice method, with Chebyshev placement, followed in 1974. Glauert’s coefficients are from 1926.

Still open: how close a neighbour a panel can live with

The ground figure measures one panel’s failure against one kind of neighbour. The next calculation would make that into a rule: for a section with a neighbouring vortex at a distance dd, compute the error in lift against NN and dd for panels of a chord over NN, and ask whether the error collapses on the single variable d/hd/h with hh the panel size. If it does, the panel count a tandem, a slot or a ground problem needs can be stated in one line, and a user would know how close is too close before starting; if it doesn’t, there’s an effect beyond the local curvature of the onset flow that these figures have not identified.

What links here

Computed from the collection rather than written here: the essays that point at this one.

Reads more easily once this is understood

Essays that name this one as worth reading first.

Shares its objects with

Essays naming at least two of the same things, that neither author linked.

Named objects

A dashed tag is an object no other essay names yet.

ConvergenceDiscretisationKutta conditionLift coefficientModel limitPanel methodThin-aerofoil theoryVortex sheet