Circulation and lift

The suction pays for the nose the lift could ignore

A panel method's lift barely notices a vortex under the leading edge, because the lift weights the onset flow by a factor that vanishes there. The leading-edge suction, read from the same panels, weights it the opposite way: uniformly in Glauert's angle, which in distance along the chord is singular at both edges. A vortex under the tail sets the nose's suction exactly as strongly as one under the nose. On cosine panels the suction error is one curve of gap over panel at both ends, it falls only as the first power of that ratio, and the nose — cheap for the lift — is now the edge that costs eight times the panels.

Worth reading first: The nose is cheap and the tail is not · A finite force from an infinite speed.

The nose is cheap and the tail is not put a flat plate of unit chord beside a free point vortex, crowded lumped-vortex panels towards both edges at the cosine points, and found that the lift’s error under the leading edge had been misread. It did not need fixing; it needed dividing by the square root of the gap, because the lift weights the onset flow by Glauert’s factor 1−cos⁡θ1-\cos\theta, which vanishes at the nose. A vortex just under the leading edge controls only 2d\sqrt{2d} of the lift, so any error confined to that region is a fraction of a small quantity. Under the trailing edge the weight is two, the vortex owns the lift, and one panel per gap costs about three per cent.

That essay ended by naming the force that should behave the other way. The leading-edge suction is the thrust a sharp edge feels when the flow turns round it: finite, though the speed there is infinite, as a finite force from an infinite speed showed, and fixed entirely by the strength of the square-root singularity in the vortex sheet at the nose. Its formula weights the onset flow differently from the lift. If the weights decide which edge is dear, the suction should find the nose expensive and the tail cheap. This essay computes it, and the prediction comes out half right — which half is the interesting part.

Glauert’s first coefficient, in closed form

Thin-aerofoil theory writes the vortex sheet on a plate as a series in Glauert’s angle θ\theta, where x=(1−cos⁡θ)/2x=(1-\cos\theta)/2:

γ(θ)=2(A0cot⁡θ2+∑n≥1Ansin⁡nθ),A0=1π∫0πw dθ,\gamma(\theta)=2\left(A_0\cot\tfrac{\theta}{2}+\sum_{n\ge1}A_n\sin n\theta\right),\qquad A_0=\frac1\pi\int_0^\pi w\,d\theta,

with ww the normal velocity the sheet must cancel. Only the first term is singular: cot⁡(θ/2)=(1−x)/x\cot(\theta/2)=\sqrt{(1-x)/x}, so near the nose the sheet is 2A0/x2A_0/\sqrt x, and the suction is cs=2πA02c_s=2\pi A_0^2. For a plate at incidence α\alpha, A0=αA_0=\alpha, the lift is 2πα2\pi\alpha and the suction 2πα2=clα2\pi\alpha^2=c_l\alpha, exactly what cancels the tilt of the normal force; that is how a flat plate in ideal flow escapes having any drag at all.

The weight in A0A_0 is uniform in θ\theta, and in distance along the chord dθ=dx/x(1−x)d\theta=dx/\sqrt{x(1-x)}: singular at both edges, with the same strength. For a unit vortex at z=x0+idz=x_0+\mathrm{i}d below the plate, the integral has a closed form, because the onset is the real part of a simple pole and the Chebyshev weight integrates a pole exactly:

A0=12π Re 1z z−1.A_0=\frac1{2\pi}\,\mathrm{Re}\,\frac{1}{\sqrt{z}\,\sqrt{z-1}} .

A vortex under either edge sets the suction by the same inverse square root: the weight is singular at both ends. The size of Glauert's A₀, which fixes the leading-edge suction, induced by a unit vortex a distance d below the plate, against d. Under the leading edge and under the trailing edge the two curves coincide and follow 1/(2π√(2d)): 3.56 at d = 0.001 against 3.56, with opposite signs. Under the quarter-chord A₀ stays small, 4.9·10⁻⁴, because the weight there is smooth and the vortex's flow changes sign across it; under mid-chord it is zero by symmetry.
Fig. 1 The size of A0A_0 a unit vortex induces at a distance dd below the plate, under the leading edge, the trailing edge and the quarter-chord, against 1/(2π2d)1/(2\pi\sqrt{2d}). Under either edge it is 3.56 at d=0.001d=0.001, with opposite signs; under the quarter-chord it is 4.9×10−44.9\times10^{-4}, and under mid-chord exactly zero.

Under the nose, z=idz=\mathrm{i}d and the closed form tends to −1/(2π2d)-1/(2\pi\sqrt{2d}); under the tail, z=1+idz=1+\mathrm{i}d, it tends to +1/(2π2d)+1/(2\pi\sqrt{2d}). The two curves are the same curve. A vortex under the trailing edge changes the suction at the leading edge exactly as much as one the same distance under the nose, with the sign reversed. Away from the edges the vortex barely touches it: under the quarter-chord, at a thousandth of a chord, A0A_0 is seven thousand times smaller than under either edge, because there the weight is smooth and the vortex’s flow, up on one side of it and down on the other, cancels against it. Under mid-chord it cancels exactly.

The equality of the two edges is the surprising connection in this calculation, and it is the Kutta condition at work. The sheet must be finite at the trailing edge. A vortex under the tail pushes the sheet there hard, and the only freedom the plate has to keep its trailing-edge loading finite is the circulation, which it adjusts — and the singular term at the nose is where the adjustment shows. The suction at one edge is the price of the condition imposed at the other.

Read from the first panel

A lumped-vortex panel method has no A0A_0. It has a vortex of strength Γi\Gamma_i at the quarter-point of each panel, chosen so the normal velocity vanishes at each three-quarter point. The singularity lives in the first panel: the exact sheet integrated over a first panel of length h1h_1 is about 4A0h14A_0\sqrt{h_1}, and the regular part of the sheet adds only something proportional to h1h_1. So the suction is read from Γ1\Gamma_1. The reading used here is calibrated: the same panels are solved once for a uniform onset, whose A0A_0 is known, and the neighbour’s A0A_0 is taken as Γ1\Gamma_1 in proportion. That makes the reading exact for a plate at incidence, so every bit of its error belongs to the neighbour.

Under the nose the suction error is one curve on the gap over the first panel, and it falls only as its inverse. The size of the error in the leading-edge suction, read from the first of 8 to 128 cosine-spaced panels, for a vortex under the leading edge, against the gap over the first panel's length. The five curves coincide: at a gap of one first panel the error is 34 per cent on 8 panels and 34 on 128, and beyond a few panels it follows 0.37 divided by the ratio.
Fig. 2 The size of the suction error read from the first of 8 to 128 cosine-spaced panels, for a vortex under the leading edge, against the gap over the first panel’s length. The five curves lie on one: 34 per cent at a gap of one first panel on every count, and beyond a few panels about 0.37 divided by the ratio.

Under the nose the prediction holds where the lift’s did not. The five curves are one. At a gap equal to the first panel’s length the suction is 34 per cent wrong on 8 panels and 34 per cent wrong on 128; at four panels’ gap 9 per cent on every count from 16 up. The error is a function of the gap over the panel alone, with no square root of the gap in front of it — the raw collapse the lift failed to show under the nose. That much of the prediction is right.

What the prediction did not say is how slowly the curve falls. Beyond a few panels it goes as 0.37/r0.37/r, with rr the gap over the first panel’s length: the first power. To bring the suction under one per cent the gap must be about 37 first panels, and since a cosine first panel is π2/(4N2)\pi^2/(4N^2) of the chord, the count needed grows only as the inverse square root of the gap — but from a large constant.

Under the tail it collapses too

The other half of the prediction was that under the trailing edge the error would be suppressed, by a power of the gap, as the lift’s was under the nose. It is not suppressed.

Under the tail the suction error collapses too, at about a third of the nose's. The same error for a vortex under the trailing edge, against the gap over the last panel's length, which on cosine spacing equals the first. The curves converge on one: at a gap of one panel 11 per cent on 8 panels and 6 on 128, and beyond a few panels about 0.13 divided by the ratio, against the nose's 0.37.
Fig. 3 The same error for a vortex under the trailing edge, against the gap over the last panel’s length, which on cosine spacing equals the first. The curves converge on one: 11 per cent on 8 panels and 6.5 on 128 at one panel’s gap, and about 0.13 divided by the ratio beyond a few panels.

The curves converge on one curve here as well, from 11 per cent on eight panels to 6.5 on 128 at a gap of one panel, and beyond a few panels it too falls as the first power of the ratio, 0.13/r0.13/r. That is a third of the nose’s constant rather than a vanishing fraction of it. The weight explains why: it is singular at the tail with exactly the strength it has at the nose, so there is no small factor to suppress anything. The lift’s two edges differed because its weight differed, zero at one end and two at the other; the suction’s two edges are alike because its weight is alike.

They are not identical, and the difference is the panel method’s, not the physics’. The exact A0A_0 is the same magnitude under both edges; what differs is how far the error has to travel. Under the nose the vortex’s local flow lands on the very panel the suction is read from. Under the tail it lands on the last panel, and reaches the first only through the solve, as a change in the circulation the Kutta condition demands — a route that smooths it. The nose is therefore three times as dear per unit of gap.

Along the chord, and why away from the edges does not matter

Away from the edges the suction error falls fast once the gap passes a few panels, and under the nose it does notThe size of the suction error on 8 to 128 cosine-spaced panels against the gap over the nearest panel's length, with the vortex under the leading edge. On 128 panels it is 34 per cent at a gap of one panel, 9 at four and 2.3 at sixteen. Away from the edges the suction a vortex induces is small, and at gaps under a panel the relative error there runs into hundreds of per cent.10⁰10¹10⁻⁴10⁻³10⁻²10⁻¹10⁰gap ÷ nearest panel's length|suction error|8 panels16 panels32 panels64 panels128 panelsa flat plate of unit chord, linearised, beside a free unit vortex; suction read from the leading panel's strengthinviscid, steady, the vortex held fixed; exact suction from the closed form of Glauert's A₀
Fig. 4 The suction error on 8 to 128 cosine-spaced panels against the gap over the nearest panel, with the vortex under the leading edge: 34 per cent at one panel’s gap, 9 at four, 2.3 at sixteen on 128 panels. Dialled to the quarter-chord, three-quarter chord and trailing edge, the error at four panels’ gap is 0.28, 0.16 and 3.1 per cent.

Dialled to the quarter-chord or the three-quarter chord, the picture changes character. At a gap under a panel the relative error runs into hundreds of per cent — but of a suction the vortex barely changes, since A0A_0 there is thousands of times smaller than at the edges. Once the gap passes a few panels the error falls fast, to a few tenths of a per cent at four panels’ gap. A vortex over the middle of a plate is the one neighbour a panel method can mis-resolve without consequence for the suction, which is the mirror of the lift, for which mid-chord was where one panel per gap gave a third of a per cent and the trailing edge was where it gave three.

The order the suction is computed to

The first-order fall is the thing a user of panel codes would most want to know, and it is also visible at a fixed gap as the panels are refined.

At a fixed gap the suction converges as the square of the panel count on cosine panels, and stalls on equal ones. The size of the suction error against the panel count for a vortex a hundredth of a chord below the plate, under the leading and trailing edges, on cosine-spaced and equal panels. Under the nose 128 cosine panels give 0.56 per cent and 256 give 0.14; 256 equal panels still give 18. For a vortex half a chord upstream, where the onset is smooth, equal panels converge only at first order.
Fig. 5 The size of the suction error against the panel count for a vortex a hundredth of a chord below the plate, under each edge, on cosine-spaced and equal panels. Under the nose 128 cosine panels give 0.56 per cent and 256 give 0.14; 256 equal panels still give 18.

At a fixed gap of a hundredth of a chord, cosine panels converge as the square of the count once the first panel is well inside the gap: 0.56 per cent on 128, 0.14 on 256. That is the first-order law of the previous figures in disguise. A cosine first panel shrinks as 1/N21/N^2, so a fixed gap holds r∝N2r\propto N^2 first panels and the error 0.37/r0.37/r falls as 1/N21/N^2. Equal panels are a different story. Their first panel shrinks only as 1/N1/N, so they converge at first order at best, and at a hundredth of a chord they have not begun: 256 equal panels still leave 18 per cent. Even a vortex half a chord upstream of the plate, whose flow is smooth across every panel, gives a suction on equal panels that converges only at first order — 9 per cent on 8 panels, 0.6 on 128 — while cosine panels converge at second order for the same smooth onset.

So the reading of the suction from the leading panel is first order in the leading panel’s length, whatever the onset, and cosine spacing earns its second order only because it makes that length shrink as the square of the count. The lift has no such weakness: the quarter-chord, three-quarter-chord rule makes it exact for any onset that varies linearly across a panel, and the errors of individual panels cancel in the sum. The suction is one panel’s strength, and nothing cancels.

Where A0A_0 is a decision, not a force

The expense would be a curiosity if the suction were only ever wanted as a small thrust. It is wanted for more than that. Ramesh, Gopalarathnam and their co-workers proposed in 2014 that a leading edge sheds a vortex when A0A_0 — which they called the leading-edge suction parameter — passes a critical value set by the section’s shape and Reynolds number, and not otherwise. In their discrete-vortex method the sheet on the aerofoil is solved at each time step beside every vortex the flow has shed so far, and at each step A0A_0 is compared with its critical value to decide whether a new vortex is released at the nose. The method reproduces the start and stop of leading-edge vortex shedding on pitching and plunging plates with one number per section, which is why it has been widely taken up.

That is precisely the situation computed here: a plate, its own shed vortices close to it, and A0A_0 read from a discretised sheet. The shed vortices sit near the leading edge by construction — that is where they were released — and they are close in units of the first panel unless the panels near the nose are very fine. A reading of A0A_0 that is 34 per cent wrong in the suction at one panel’s gap is 16 per cent wrong in A0A_0 itself, and a threshold criterion turns a 16 per cent error into a shedding event early or late, or into one that does not happen. The lift would show nothing: it converges eight times sooner, so a solution can look converged by every integrated force and still be deciding when to shed on an unconverged number. The first-order law gives the remedy as a number: to read A0A_0 to a few per cent beside a vortex at gap dd under the nose, the first panel has to be some tens of times shorter than dd.

The rule, for each force

For the suction the nose is the expensive edge: eight times the panels the lift needed there. The smallest power-of-two count of cosine-spaced panels that brings the error under one per cent, against the vortex's distance below the plate, for the suction and for the lift. Under the leading edge the suction needs 256, 128, 128, 64, 32, 32, 32 for gaps of 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.4 chords, where the lift needed 16, 16, 8, 8, 4, 4, 4; under the trailing edge the suction needs 128, 64, 64, 32, 32, 16, 16 and the lift 64, 64, 32, 32, 32, 16, 16.
Fig. 6 The smallest power-of-two count of cosine-spaced panels that brings the error under one per cent, against the vortex’s distance below the plate, for the suction and for the lift. Under the leading edge the suction needs 256, 128, 128, 64, 32, 32 and 32 for gaps from 0.005 to 0.4 chords, where the lift needed 16, 16, 8, 8, 4, 4 and 4; under the trailing edge the suction needs 128 down to 16, the lift 64 down to 16.

Put as a rule, the result is that the edge a panel method has to resolve depends on which force is being asked for. For the lift, the trailing edge decides: a vortex under the tail needs 64 cosine panels at a hundredth of a chord, a vortex under the nose 16. For the suction, the leading edge decides, and needs 128 at the same gap, eight times what the lift needed there. At the tail the two forces ask for comparable counts. At a gap of 0.4 chords, where no reader would think of a vortex as a near neighbour, the suction still needs 32 panels for one per cent, against the lift’s four, because of the first-order reading.

What could have disagreed

Three checks could have refused the calculation. The closed form for A0A_0 was compared with a quadrature of Glauert’s integral at 400,000 points in θ\theta, under both edges and off the plate, and agrees to five parts in a hundred trillion. The edge asymptotes were compared with the closed form at a gap of a millionth of a chord, where they agree to five parts in ten million, and the closed form is zero under mid-chord to rounding, as symmetry says it must be. The calibrated reading was checked to be exact for a uniform onset, and its order was measured for a distant vortex: slope −2.00 against the count on cosine panels and −0.99 on equal ones.

The suction beside a vortex: the checks. The closed form of A₀ against a quadrature, the edge asymptotes, the calibration on a uniform onset, the orders of convergence for a distant vortex on cosine and equal panels, the raw collapse at both edges, and the first-order fall at the nose.
Fig. 7 The closed form against the quadrature, the two edge asymptotes, the calibration on a uniform onset, the orders of convergence for a distant vortex on cosine and equal panels, the raw collapse under the nose at four panels’ gap, the first-order fall, and the ratio of the nose’s error to the tail’s at one panel’s gap.

The collapse itself is checked rather than read off a picture: under the nose, the error at a gap of four first panels on 32, 64 and 128 panels spreads by less than one per cent of itself; the product of the ratio and the error is the same at eight and at thirty-two panels’ gap to within one per cent, which is what the first-order law means; and at one panel’s gap the nose’s error is five times the tail’s.

The convention the suction is stated in

The suction here is the coefficient cs=2πA02c_s=2\pi A_0^2 on a unit chord, in a unit stream, with the plate at no incidence and the whole of A0A_0 coming from the neighbour. Its error is (A0panel/A0)2−1(A_0^{\text{panel}}/A_0)^2-1, so a 34 per cent error in the suction is a 16 per cent error in A0A_0. The gap is measured from the plate to the vortex, in chords, and divided by the length of the panel nearest the vortex — the first under the nose, the last under the tail, which on cosine spacing are equal. The lift results quoted for comparison are the previous calculation’s, on the same panels and the same vortex.

The calibrated reading is one choice among several. A panel method can instead fit the first few panel strengths to the singular form, or use panels whose own vorticity carries the square root, and either would change the constant in the first-order law. What it cannot change is the weight: any reading of the suction weights the onset uniformly in θ\theta, so a vortex under either edge matters equally to it, and a reading built from one panel cannot do better than that panel’s own error.

What a flat plate cannot show

A real leading edge is round. On a rounded nose the singularity is replaced by a finite peak of suction, spread over a distance of the order of the nose radius, and the suction becomes a pressure integrated over that region rather than the strength of a singular term. A panel method on a thick section resolves that peak, and its error then depends on the gap over the nose radius as well as the gap over the panel, which this calculation cannot say anything about. Nor does it say what a real neighbour would do. A vortex that passes this close to an edge — a blade’s own shed vortex meeting the next blade, as in a blade that flies through what it shed — induces a suction large enough to separate the flow at a real edge, and a sharp edge that cannot hold its suction pays for it in drag, as a wing that cannot hold its suction counted. The linear plate holds every suction it is given.

Who found it, and when

Glauert set out the series in θ\theta and the coefficient A0A_0 in his 1926 book on aerofoil theory, and the leading-edge thrust as the limit of the pressure round a sharp edge was understood by Prandtl’s school by the 1920s; nothing but the edge traces it. The lumped-vortex rule, a vortex at a quarter of each panel and the condition at three quarters, is Weissinger’s, and James showed in 1972 that it reproduces the flat plate’s lift exactly on any number of panels. Polhamus turned the lost suction of a sharp-edged delta wing into a prediction of its vortex lift in 1966. The closed form for A0A_0 beside a point vortex follows from the Chebyshev integral that one panel is exact and every panel is wrong and where lift starts both lean on.

Still open: whether a rounded nose gives the suction back its square root

The flat plate’s suction is a property of its singularity, and that is the part of the calculation a real section does not have. The next calculation would put the vortex beside a thin symmetric section with a parabolic nose of stated radius, solved by a source and vortex panel method that resolves the nose, and integrate the suction from the pressures round the nose rather than read it from a singular term. It would ask whether, once the gap falls below the nose radius, the suction error stops collapsing on the gap over the panel and starts collapsing on the gap over the radius — whether the round nose, which carries a finite peak instead of a singularity, turns the suction’s first-order law back into the second-order one the lift enjoys, and so whether the expense found here is a property of the suction or of the sharp edge it was read from.

What links here

Computed from the collection rather than written here: the essays that point at this one.

Shares its objects with

Essays naming at least two of the same things, that neither author linked.

Named objects

A dashed tag is an object no other essay names yet.

ConvergenceDiscretisationKutta conditionLeading edge suctionModel limitPanel methodSingularityThin-aerofoil theory