The suction pays for the nose the lift could ignore
Worth reading first: The nose is cheap and the tail is not · A finite force from an infinite speed.
The nose is cheap and the tail is not put a flat plate of unit chord beside a free point vortex, crowded lumped-vortex panels towards both edges at the cosine points, and found that the lift’s error under the leading edge had been misread. It did not need fixing; it needed dividing by the square root of the gap, because the lift weights the onset flow by Glauert’s factor , which vanishes at the nose. A vortex just under the leading edge controls only of the lift, so any error confined to that region is a fraction of a small quantity. Under the trailing edge the weight is two, the vortex owns the lift, and one panel per gap costs about three per cent.
That essay ended by naming the force that should behave the other way. The leading-edge suction is the thrust a sharp edge feels when the flow turns round it: finite, though the speed there is infinite, as a finite force from an infinite speed showed, and fixed entirely by the strength of the square-root singularity in the vortex sheet at the nose. Its formula weights the onset flow differently from the lift. If the weights decide which edge is dear, the suction should find the nose expensive and the tail cheap. This essay computes it, and the prediction comes out half right — which half is the interesting part.
Glauert’s first coefficient, in closed form
Thin-aerofoil theory writes the vortex sheet on a plate as a series in Glauert’s angle , where :
with the normal velocity the sheet must cancel. Only the first term is singular: , so near the nose the sheet is , and the suction is . For a plate at incidence , , the lift is and the suction , exactly what cancels the tilt of the normal force; that is how a flat plate in ideal flow escapes having any drag at all.
The weight in is uniform in , and in distance along the chord : singular at both edges, with the same strength. For a unit vortex at below the plate, the integral has a closed form, because the onset is the real part of a simple pole and the Chebyshev weight integrates a pole exactly:
Under the nose, and the closed form tends to ; under the tail, , it tends to . The two curves are the same curve. A vortex under the trailing edge changes the suction at the leading edge exactly as much as one the same distance under the nose, with the sign reversed. Away from the edges the vortex barely touches it: under the quarter-chord, at a thousandth of a chord, is seven thousand times smaller than under either edge, because there the weight is smooth and the vortex’s flow, up on one side of it and down on the other, cancels against it. Under mid-chord it cancels exactly.
The equality of the two edges is the surprising connection in this calculation, and it is the Kutta condition at work. The sheet must be finite at the trailing edge. A vortex under the tail pushes the sheet there hard, and the only freedom the plate has to keep its trailing-edge loading finite is the circulation, which it adjusts — and the singular term at the nose is where the adjustment shows. The suction at one edge is the price of the condition imposed at the other.
Read from the first panel
A lumped-vortex panel method has no . It has a vortex of strength at the quarter-point of each panel, chosen so the normal velocity vanishes at each three-quarter point. The singularity lives in the first panel: the exact sheet integrated over a first panel of length is about , and the regular part of the sheet adds only something proportional to . So the suction is read from . The reading used here is calibrated: the same panels are solved once for a uniform onset, whose is known, and the neighbour’s is taken as in proportion. That makes the reading exact for a plate at incidence, so every bit of its error belongs to the neighbour.
Under the nose the prediction holds where the lift’s did not. The five curves are one. At a gap equal to the first panel’s length the suction is 34 per cent wrong on 8 panels and 34 per cent wrong on 128; at four panels’ gap 9 per cent on every count from 16 up. The error is a function of the gap over the panel alone, with no square root of the gap in front of it — the raw collapse the lift failed to show under the nose. That much of the prediction is right.
What the prediction did not say is how slowly the curve falls. Beyond a few panels it goes as , with the gap over the first panel’s length: the first power. To bring the suction under one per cent the gap must be about 37 first panels, and since a cosine first panel is of the chord, the count needed grows only as the inverse square root of the gap — but from a large constant.
Under the tail it collapses too
The other half of the prediction was that under the trailing edge the error would be suppressed, by a power of the gap, as the lift’s was under the nose. It is not suppressed.
The curves converge on one curve here as well, from 11 per cent on eight panels to 6.5 on 128 at a gap of one panel, and beyond a few panels it too falls as the first power of the ratio, . That is a third of the nose’s constant rather than a vanishing fraction of it. The weight explains why: it is singular at the tail with exactly the strength it has at the nose, so there is no small factor to suppress anything. The lift’s two edges differed because its weight differed, zero at one end and two at the other; the suction’s two edges are alike because its weight is alike.
They are not identical, and the difference is the panel method’s, not the physics’. The exact is the same magnitude under both edges; what differs is how far the error has to travel. Under the nose the vortex’s local flow lands on the very panel the suction is read from. Under the tail it lands on the last panel, and reaches the first only through the solve, as a change in the circulation the Kutta condition demands — a route that smooths it. The nose is therefore three times as dear per unit of gap.
Along the chord, and why away from the edges does not matter
Dialled to the quarter-chord or the three-quarter chord, the picture changes character. At a gap under a panel the relative error runs into hundreds of per cent — but of a suction the vortex barely changes, since there is thousands of times smaller than at the edges. Once the gap passes a few panels the error falls fast, to a few tenths of a per cent at four panels’ gap. A vortex over the middle of a plate is the one neighbour a panel method can mis-resolve without consequence for the suction, which is the mirror of the lift, for which mid-chord was where one panel per gap gave a third of a per cent and the trailing edge was where it gave three.
The order the suction is computed to
The first-order fall is the thing a user of panel codes would most want to know, and it is also visible at a fixed gap as the panels are refined.
At a fixed gap of a hundredth of a chord, cosine panels converge as the square of the count once the first panel is well inside the gap: 0.56 per cent on 128, 0.14 on 256. That is the first-order law of the previous figures in disguise. A cosine first panel shrinks as , so a fixed gap holds first panels and the error falls as . Equal panels are a different story. Their first panel shrinks only as , so they converge at first order at best, and at a hundredth of a chord they have not begun: 256 equal panels still leave 18 per cent. Even a vortex half a chord upstream of the plate, whose flow is smooth across every panel, gives a suction on equal panels that converges only at first order — 9 per cent on 8 panels, 0.6 on 128 — while cosine panels converge at second order for the same smooth onset.
So the reading of the suction from the leading panel is first order in the leading panel’s length, whatever the onset, and cosine spacing earns its second order only because it makes that length shrink as the square of the count. The lift has no such weakness: the quarter-chord, three-quarter-chord rule makes it exact for any onset that varies linearly across a panel, and the errors of individual panels cancel in the sum. The suction is one panel’s strength, and nothing cancels.
Where is a decision, not a force
The expense would be a curiosity if the suction were only ever wanted as a small thrust. It is wanted for more than that. Ramesh, Gopalarathnam and their co-workers proposed in 2014 that a leading edge sheds a vortex when — which they called the leading-edge suction parameter — passes a critical value set by the section’s shape and Reynolds number, and not otherwise. In their discrete-vortex method the sheet on the aerofoil is solved at each time step beside every vortex the flow has shed so far, and at each step is compared with its critical value to decide whether a new vortex is released at the nose. The method reproduces the start and stop of leading-edge vortex shedding on pitching and plunging plates with one number per section, which is why it has been widely taken up.
That is precisely the situation computed here: a plate, its own shed vortices close to it, and read from a discretised sheet. The shed vortices sit near the leading edge by construction — that is where they were released — and they are close in units of the first panel unless the panels near the nose are very fine. A reading of that is 34 per cent wrong in the suction at one panel’s gap is 16 per cent wrong in itself, and a threshold criterion turns a 16 per cent error into a shedding event early or late, or into one that does not happen. The lift would show nothing: it converges eight times sooner, so a solution can look converged by every integrated force and still be deciding when to shed on an unconverged number. The first-order law gives the remedy as a number: to read to a few per cent beside a vortex at gap under the nose, the first panel has to be some tens of times shorter than .
The rule, for each force
Put as a rule, the result is that the edge a panel method has to resolve depends on which force is being asked for. For the lift, the trailing edge decides: a vortex under the tail needs 64 cosine panels at a hundredth of a chord, a vortex under the nose 16. For the suction, the leading edge decides, and needs 128 at the same gap, eight times what the lift needed there. At the tail the two forces ask for comparable counts. At a gap of 0.4 chords, where no reader would think of a vortex as a near neighbour, the suction still needs 32 panels for one per cent, against the lift’s four, because of the first-order reading.
What could have disagreed
Three checks could have refused the calculation. The closed form for was compared with a quadrature of Glauert’s integral at 400,000 points in , under both edges and off the plate, and agrees to five parts in a hundred trillion. The edge asymptotes were compared with the closed form at a gap of a millionth of a chord, where they agree to five parts in ten million, and the closed form is zero under mid-chord to rounding, as symmetry says it must be. The calibrated reading was checked to be exact for a uniform onset, and its order was measured for a distant vortex: slope −2.00 against the count on cosine panels and −0.99 on equal ones.
The collapse itself is checked rather than read off a picture: under the nose, the error at a gap of four first panels on 32, 64 and 128 panels spreads by less than one per cent of itself; the product of the ratio and the error is the same at eight and at thirty-two panels’ gap to within one per cent, which is what the first-order law means; and at one panel’s gap the nose’s error is five times the tail’s.
The convention the suction is stated in
The suction here is the coefficient on a unit chord, in a unit stream, with the plate at no incidence and the whole of coming from the neighbour. Its error is , so a 34 per cent error in the suction is a 16 per cent error in . The gap is measured from the plate to the vortex, in chords, and divided by the length of the panel nearest the vortex — the first under the nose, the last under the tail, which on cosine spacing are equal. The lift results quoted for comparison are the previous calculation’s, on the same panels and the same vortex.
The calibrated reading is one choice among several. A panel method can instead fit the first few panel strengths to the singular form, or use panels whose own vorticity carries the square root, and either would change the constant in the first-order law. What it cannot change is the weight: any reading of the suction weights the onset uniformly in , so a vortex under either edge matters equally to it, and a reading built from one panel cannot do better than that panel’s own error.
What a flat plate cannot show
A real leading edge is round. On a rounded nose the singularity is replaced by a finite peak of suction, spread over a distance of the order of the nose radius, and the suction becomes a pressure integrated over that region rather than the strength of a singular term. A panel method on a thick section resolves that peak, and its error then depends on the gap over the nose radius as well as the gap over the panel, which this calculation cannot say anything about. Nor does it say what a real neighbour would do. A vortex that passes this close to an edge — a blade’s own shed vortex meeting the next blade, as in a blade that flies through what it shed — induces a suction large enough to separate the flow at a real edge, and a sharp edge that cannot hold its suction pays for it in drag, as a wing that cannot hold its suction counted. The linear plate holds every suction it is given.
Who found it, and when
Glauert set out the series in and the coefficient in his 1926 book on aerofoil theory, and the leading-edge thrust as the limit of the pressure round a sharp edge was understood by Prandtl’s school by the 1920s; nothing but the edge traces it. The lumped-vortex rule, a vortex at a quarter of each panel and the condition at three quarters, is Weissinger’s, and James showed in 1972 that it reproduces the flat plate’s lift exactly on any number of panels. Polhamus turned the lost suction of a sharp-edged delta wing into a prediction of its vortex lift in 1966. The closed form for beside a point vortex follows from the Chebyshev integral that one panel is exact and every panel is wrong and where lift starts both lean on.
Still open: whether a rounded nose gives the suction back its square root
The flat plate’s suction is a property of its singularity, and that is the part of the calculation a real section does not have. The next calculation would put the vortex beside a thin symmetric section with a parabolic nose of stated radius, solved by a source and vortex panel method that resolves the nose, and integrate the suction from the pressures round the nose rather than read it from a singular term. It would ask whether, once the gap falls below the nose radius, the suction error stops collapsing on the gap over the panel and starts collapsing on the gap over the radius — whether the round nose, which carries a finite peak instead of a singularity, turns the suction’s first-order law back into the second-order one the lift enjoys, and so whether the expense found here is a property of the suction or of the sharp edge it was read from.
What links here
Computed from the collection rather than written here: the essays that point at this one.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- The part of the flow inside the body — both name convergence, leading edge suction, model limit, thin-aerofoil theory
- A jet flap is a flap made of the jet — both name kutta condition, model limit, thin-aerofoil theory
- A load carried to the trailing edge needs a hook — both name kutta condition, model limit, thin-aerofoil theory
- A NACA section multiplies its lift by nearly one plus its thickness, and a nose correction cannot supply it — both name model limit, panel method, thin-aerofoil theory
- A post holds liquid back by its radius, a stripe by its length — both name convergence, model limit, singularity
- A sheet that cannot stay a sheet — both name discretisation, model limit, singularity
Named objects
A dashed tag is an object no other essay names yet.
ConvergenceDiscretisationKutta conditionLeading edge suctionModel limitPanel methodSingularityThin-aerofoil theory