Every essay — page 70
Flows and fields Ideal flow Circulation and lift Viscosity Regimes and numbers Compressible flow Transition and turbulence Fluids at work What is taught wrongly Series Concepts Regimes Refutations Search
Viscosity
The thin layer next to a surface that ideal flow ignores, and which supplies drag, separation and the wake.
A doctor blade worn in at one load falls off its film just above it
A doctor blade is a strip of spring steel a fifth of a millimetre thick, bent onto the roll by its own load, and its land is worn flat against the roll at the load it runs at. At that load it is a rigid blade floating on a parallel film. At any other load the strip bends more or less, and the land tilts. Unload it and the land converges, the film it leaves is thicker than a rigid blade's; load it by two and a half per cent more and the land opens at the back by a twentieth of a degree, carries nothing, and the film falls from more than a micrometre to a few hundredths — until the blade wears a new land at the new load.
A sloshing tank is damped by its walls, not its water
A wave sloshing in a tank of water dies away, and the obvious account is that the water's viscosity eats it. The water's interior takes almost nothing. Nearly all of the loss happens in Stokes layers a fraction of a millimetre thick on the glass, which take 248 times what the interior does in a one-metre tank. That changes how the damping scales. A tank's damping ratio falls as its size to the minus three-quarters, so a scale model in the same liquid rings out far too quickly, and a model that damped like its prototype would need a liquid thinner than any there is.
A tank's walls slow its swing by exactly what they damp
The Stokes layers on a sloshing tank's walls take its energy, and they also change its frequency — by the same amount, wall for wall, because a Stokes layer pushes on its wall an eighth of a cycle ahead of the water and so is half resistance and half extra mass. The water's own viscosity damps without detuning and surface tension raises the pitch, so the frequency and the decay measured together say which of them is at work. In a one-metre tank the walls lower the frequency by 0.09 per cent, a few centimetres of amplitude move it further, and only at one depth is the walls' shift the whole of it.
A blade worn back onto its film stops at the cliff's edge
A doctor blade worn flat at one load falls off its film a couple of per cent above it, and then, the story goes, wears a new land at the new load. Give the wearing Archard's law — material removed where the blade touches, while it touches — and it does wear a new land, but not a parallel one. Wear stops the instant the film can lift the blade again, which is at the edge of the new load's cliff. A blade that has been overloaded once runs with no margin from then on, leaves a film a fifth thinner than a land ground for its load, and wears the same amount whether its load was raised in one step or twenty.
A spill on a tilted floor stops climbing before it starts to run
On a level table a pool of syrup spreads as the eighth root of time and never stops being round. Tilt the table and a second flux joins in, carrying liquid downhill at a speed set by the square of its thickness and indifferent to any gradient. Scaled on the one length the tilt and the volume make, every spill on every slope is the same spill: its uphill edge climbs to three-quarters of that length and freezes there for good, and the rest runs away downhill as a tongue thickest at its nose and growing as the cube root of time.