A sloshing tank is damped by its walls, not its water
Worth reading first: What a fluid takes out of a swing · The wall that shakes.
Carry a full tray of water across a room and the surface keeps swinging after the tray has stopped. Set it down and the swing goes on for a long while, longer than seems reasonable for something so slight, before it settles to a flat surface. Something is taking the energy out, and the obvious candidate is the water’s viscosity. Water is a viscous fluid and the wave moves it, so the wave is damped by the water. A textbook formula backs this up. Lamb’s rate for the decay of a free wave’s amplitude is , from the viscous stress spread through the bulk of the moving water.
In a tank the formula’s prediction is wrong by a factor of a couple of hundred, and the error has a consequence. The wave doesn’t lose its energy in the water. It loses it on the walls. On every solid surface the wave slides past there’s a Stokes layer, of the kind the wall that shakes solved exactly, less than a millimetre thick. Those layers take almost all of the loss. What a fluid takes out of a swing used the same layer to price the damping of a sphere or a tuning fork moving through still fluid. Here the body holds still and the fluid oscillates past it, and the account is the same. The essay on films found the layer forming under the free surface once a film stops that surface sliding. A tank has its layers already, on five of its six faces.
The proportions are the first result here. The second is what they do to scaling, because a loss on a surface scales differently from a loss through a volume, and the difference reaches into every model test of sloshing.
One mode, five surfaces, and an energy budget
The tank is rectangular, of length in the direction the wave runs, breadth across it and liquid depth . Its lowest mode has half a wavelength across the length, , and the inviscid frequency of a standing gravity wave, . For the one-metre tank half full that’s 0.846 Hz, a swing of a little over a second. Writing the surface as , the velocity has amplitudes
That flow is irrotational and slips freely along every wall, which a real liquid can’t do. Within a thickness of each wall, the velocity is brought to rest by a Stokes layer, whose profile is the oscillating-plate solution with the frame changed. In water at this frequency, mm. The layer dissipates energy at a mean rate of
per unit area, where is the amplitude of the slip velocity the outer flow tries to have at that point. This is the same quantity the price of a gradient computes for a shaken plate, written for the case where the plate stands still and the fluid moves.
The wave’s energy is , half of it kinetic and half potential on average, and the amplitude decays at , where is the total dissipation. Each surface needs the square of its own slip integrated over its own area. On the bottom only slides. On the two end walls only slides. On the two side walls both components slide, because the wave runs along them. The integrals close, and with substituted, each piece comes out tidy:
The interior has its own term, from integrated through the volume of an irrotational flow. It comes to , Lamb’s rate, and at every depth, not only in deep water where Lamb derived it. That’s not obvious beforehand: the depth enters the strain rates and the energy through the same factor, , and cancels. The side-wall term is the simplest of the five, just the reciprocal of the breadth. Along a side wall the squared slip averages to a profile whose integral is exactly proportional to the wave’s own kinetic energy per unit breadth. So the side walls take a fixed fraction of the energy at every depth.
For the one-metre tank the five numbers, in thousandths per second, are 3.26 for the side walls, 1.19 for the ends, 0.444 for the bottom and 0.0197 for the interior. The walls and floor together come to 4.89, and the interior is a 248th of that. The damping ratio, , is 0.0924 per cent, and the amplitude halves in 141 seconds, or 119 of its own swings. That’s the slow fade of the tray, explained, and almost none of it is the water’s doing.
Why the thin layer beats the whole volume
That a layer 0.6 mm thick should out-dissipate half a cubic metre of water looks wrong until the strain rates are compared. In the interior the velocity varies over a wavelength, so the strain rate goes as . In the layer it changes by the full slip velocity across , so the strain rate goes as . Dissipation goes as the square of the strain rate times the volume it acts in. The layer has a volume of times the wall area, and the interior one of order the tank’s volume. The ratio of the two losses is therefore of order
with a geometric factor in front. For the one-metre tank, , so is 520, and the geometric factor brings the computed ratio to 248. The layer is thin, and that’s precisely why it wins: its gradient is steeper by a factor that more than pays for its small volume.
What a fluid takes out of a swing found the same arithmetic in a sphere’s damping coefficient, , where the second term overtakes the first as soon as the layer is thinner than the sphere. A tank is that sphere turned inside out. Its “size” is the wavelength, and its layer is so much thinner than any tank that the first term, the counterpart of the bulk, never has a chance.
Smaller tanks swing faster and still die sooner
Make every dimension of the tank larger by the same factor and three things change. The frequency falls as , because and is fixed by the shape. The wall rate falls as , or . And the damping ratio, the wall rate over the frequency, falls as
The interior’s share falls faster, as , which is the square of the wall exponent. Written as a single group, goes as the inverse square root of , a Reynolds number built on the gravity wave’s own speed, and as its inverse. So the bulk is the second-order term in a small parameter, and the walls are the first.
The numbers along the figure are worth stating. A 10 cm tank of that shape has a damping ratio of 0.529 per cent and its walls take 44 times the interior. The one-metre tank sits at 0.0924 per cent and 248 times. A ten-metre tank, the size of a ship’s cargo hold, reaches 0.0164 per cent and 1,390 times. And 40 m, the scale of a large membrane tank on a gas carrier, gives 0.0058 per cent and 3,940 times. If the two lines were continued downwards they would cross at a tank of 0.64 mm. A wave in a tank that size is a capillary ripple whose Stokes layer is as thick as the tank itself, so neither half of the model describes it. Within gravity waves, the interior never wins.
The figure counts in the tank’s own periods, since that’s the comparison a damping ratio makes. In seconds, the difference is larger still. The 10 cm tank halves in 7.8 seconds, the metre tank in 141, the ten-metre tank in 2,520 (forty-two minutes) and the forty-metre tank in about four hours. That last figure is for a tank of water. A gas carrier’s tank holds liquefied natural gas, whose kinematic viscosity is a fraction of water’s, so its damping is lower still by the square root of that fraction, and a slosh started in a seaway is still there when the next wave group arrives. It’s one reason the design of those tanks is about the strength to take an impact, not about damping: damping isn’t available at that size.
Shallow tanks feed the floor and deep ones the glass
Which surface does the work depends on depth, through the shape of the velocity profile. In shallow water the horizontal velocity is nearly uniform from surface to floor, and the floor is the biggest surface it slides along. In deep water the motion decays downwards over a wavelength, the bottom is out of reach, and the walls that run alongside the wave take the loss.
The shallow end has a limit that checks the formula. In a long shallow tank the bottom term tends to . That’s the decay rate of a long wave over a floor’s Stokes layer, and it can be derived in a line from the long wave’s uniform velocity and its energy per unit area. The formula here reproduces it to two parts in a million at a depth of 1 cm in a 20 m tank. In the deep limit the bottom term vanishes and the end and side terms tend to , which is the deep-water form of the basin damping.
Between the two there’s a small surprise. The bottom and ends together, for a tank whose length is set, come to times the common factor. The correction changes sign at , where the depth is half the length, so the floor and ends together take slightly less, past that depth, than they would in an infinitely deep tank. The damping ratio has a shallow minimum near a depth of three quarters of the length, 0.0899 per cent against 0.0904 per cent deep. Half a per cent of the damping is not something anyone designs for, and it’s mentioned only because a reader computing the curve will find it. Shallow water is another matter: at 5 cm the damping ratio is 0.567 per cent, six times the half-full tank’s, all of it from the floor.
A narrow tank is mostly side wall
The side-wall term is , and nothing else in the budget depends on the breadth. Make the tank narrow and the side walls take over completely. Make it wide and the damping falls to what the floor and ends give.
That applies to every wave flume. A flume is a long narrow tank, and a wave running down it loses energy to its side walls at the rate per unit time whatever else is going on. Experiments on wave decay, breaking or wave–current interaction in a flume all subtract this loss, or ought to, before they attribute anything to the process under study. In a tank 2 cm wide, the size used for some visualisation work, the damping ratio is 1.56 per cent, and the wave loses a tenth of its amplitude every cycle. That’s not a wave that lasts very long, and whatever it was meant to show has to be read off its first few swings.
The building that needs twenty-seven times more
A tuned sloshing damper is a tank of water near the top of a tall building, sized so that its lowest mode has the building’s sway frequency. When the building sways the water sloshes against it, and if the water’s motion is damped, energy goes from the building into the water and out. The theory of tuned dampers (Den Hartog’s, for a mass on a spring) gives the best damping for an absorber whose mass is a fraction of the structure’s as , and for a two per cent mass ratio that’s 8.4 per cent.
A shallow tank tuned to a slow building — 4 m long, 1 m broad, 15 cm deep, sloshing at 0.151 Hz — gets 0.312 per cent from its walls and floor, three quarters of it from the floor. That’s twenty-seven times too little. The damper’s designers can’t change the water, and making the tank smaller to raise its damping ratio would detune it. So they put screens or slatted baffles across the flow, the same remedy a surge tank reaches for when its own swing outlasts the hammer it was built to absorb. A screen takes energy in proportion to the cube of the speed rather than through a Stokes layer, the loss with no viscosity in it that a throttled surge tank uses to damp a different swing. The Stokes layer computed here is then the thing the screens are added to overcome, and a calculation of the damper that left it out entirely would err by about four per cent.
The figure at 5 per cent on the size plot marks the same gap. No tank of plain water, at any size the plot shows, comes within a factor of three of it, and the ones that come closest are too small to tune to any building.
A scale model that rings out too soon
A sloshing test is a scale model run with Froude similarity, since gravity drives the wave. At scale the model’s times shrink by , which is easy to arrange. Its viscosity is another matter. The model that cannot be matched describes the general conflict between Froude and Reynolds similarity, which a ship tank lives with by computing the friction separately. The tank’s damping is a clean case of the same conflict with a single number that says how large it is. Since , a model in the prototype’s liquid damps times too much.
To keep the damping ratio, the model’s liquid would need a kinematic viscosity of . At 1:30 that’s 0.61 per cent of water’s, and at 1:100 a tenth of one per cent. Mercury, the thinnest common liquid by kinematic viscosity, at about , covers a factor of 4.23 in scale and no more. For a 1:30 model of a ship’s tank there’s no liquid available at all.
That seems to doom such tests, and in a linear sense it does. A resonant slosh in the model reaches an amplitude times the forcing’s, and that amplitude is thirteen times too small at 1:30. In practice the tests survive because the sloshing that matters in a gas carrier is violent and nonlinear. The amplitude is limited by breaking and impact, not by the Stokes layers, and the linear damping only sets how long a slosh lasts after the forcing stops. That’s precisely the quantity a model gets wrong. A test that measures decay in a small model and scales it up with Froude’s rules over-predicts the full-size damping by . The correction can be applied, since the scaling is known exactly for the Stokes layers. But it can’t be applied to the meniscus and contact-line losses described below, which scale differently and which, in a small model, can be the larger part.
The convention, and the number it fixes
The damping ratio used here is : the amplitude’s decay rate over the angular frequency, so that the amplitude goes as . That’s the structural engineer’s damping ratio, the coefficient in , and it equals for a quality factor . Wave papers often quote instead the energy decay rate, , or the logarithmic decrement per cycle, . The one-metre tank’s 0.0924 per cent is a logarithmic decrement of 0.0058 and a of 541. Any comparison with a measured value has to say which of the three it’s using, since they differ by factors of 2 and .
The rates are for amplitude, the energy is the wave’s mean total energy, and the dissipation is time-averaged over a cycle. The layer’s dissipation is for a flat wall; corners, where two layers meet and overlap, are counted twice, which is an error of order , 0.06 per cent here.
The model is checked against itself as well as against limits. The closed forms were compared with a direct numerical integration of the squared slip over each of the four kinds of surface and of through the volume, for the one-metre tank, and the worst disagreement among the five pieces was .
Where the clean calculation runs out
The model assumes a clean surface that slides freely along the walls, and real water in a glass tank does neither. It lies about two things in particular.
The first is the surface. Water exposed to a room picks up a film within minutes, and a film that resists stretching forms a Stokes layer under the surface itself. If the film were fully inextensible, the surface would behave like a rigid lid moving up and down, and that layer would add to the rate: 2.79 thousandths per second in the one-metre tank, more than half again what the walls take, bringing the damping ratio to 0.145 per cent. The film essay showed that a film of the right softness can do twice as much as a lid. So the true surface term lies anywhere between zero and roughly twice the bar in the first figure, depending on what’s on the water.
The second is the line where the surface meets the wall. The thin-layer picture lets the free surface slide up and down the glass as if there were nothing there. A real meniscus has a contact angle, and in clean glass that angle can stay pinned while the surface moves, or slip with hysteresis. Either changes the flow in a region of the size of the capillary length, 2.7 mm in water, which is several times the layer’s thickness. In a metre tank that’s a small correction. In a ten-centimetre one it isn’t, and measurements in small tanks repeatedly come out with more damping than the walls give. The calculation has no way to show that excess and the figures don’t contain it.
Beyond those two, the picture leaves out what happens when the amplitude is no longer small. A steep slosh breaks, runs up the end walls and slams, and the energy lost in a single impact can exceed many cycles of Stokes-layer damping. It also leaves out the frequency: the layers shift the frequency down as well as damping the wave, by an amount of the same order as , which the energy method used here can’t see. And it leaves out a tank’s inner fittings — pumps, pipework, frames — each of which separates the flow and takes energy as a bluff body would, once the slosh is large enough that the Keulegan–Carpenter number lets it shed.
A leaking cart put a sloshing tank on wheels and used a damping ratio of one per cent, which it described as typical of a smooth-walled tank. For a cubic metre of clean water the walls give 0.060 per cent, a sixteenth of that, and a fully inextensible surface would bring it to 0.107. The one per cent there is generous, and since that essay used it only to set how long the ringing lasts, its conclusions about the first acceleration and the leap are unaffected. The ringing would last longer.
Keulegan’s basins, and the century before them
The rate for a wave in the open is Stokes’s, from 1851, and Lamb wrote it into his Hydrodynamics in the form still quoted. For a tank, the boundary layers on the walls were computed for circular cylinders by Case and Parkinson in 1957, who found their measured damping above the theory. Garbis Keulegan, at the US National Bureau of Standards, derived the decay of standing waves in rectangular basins in 1959 by assuming that the loss lies in boundary layers next to the walls. He measured it in six basins of different sizes and found that for the larger ones, where surface activity could be neglected, the observed and computed rates agreed. The smaller basins damped faster than the walls allowed, which is the pattern a loss at the surface or the meniscus, scaling differently from the walls, would give.
John Miles took up the surface and the meniscus in closed basins in 1967, and Henderson and Miles measured the damping in a cylinder with a pinned contact line in 1994. Mei and Liu showed in 1973 that the boundary layers shift the frequency as well as damp the wave, a correction the energy balance cannot give. The tuned sloshing damper came into use in towers and tall buildings from the late 1980s, and its designers found what the size plot shows: the walls supply too little damping, and the screens are what work.
Still open: how a contact line scales against the walls
The calculation above is clean exactly where measurements are dirty, at the line where the surface meets the glass. A next calculation would take the simplest model of that line, a contact line pinned at the wall with the surface free elsewhere, and solve the linear sloshing problem with that condition in place of free sliding, for the rectangular tank, to find its decay rate and its frequency shift together. It would ask how the contact-line contribution scales with tank size and liquid. If it falls more slowly than , it must overtake the Stokes layers below some size, and the question is where that size is for water in glass. It would then ask what that does to the model-scaling factor : whether a small model’s excess damping is mostly the walls, which can be corrected exactly, or mostly the meniscus, which needs a different correction or a different liquid.
A second calculation, beside it, would take a tuned sloshing damper’s screen and model its quadratic loss alongside the walls’ linear one, find the amplitude at which the screen overtakes the walls, and ask whether in the light winds that set a building’s comfort criterion the walls are in fact the larger part of a damper’s damping.
What links here
Computed from the collection rather than written here: the essays that point at this one.
Reads more easily once this is understood
Essays that name this one as worth reading first.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- A drop rings like a bell — both name damping, model limit, oscillation
- Long enough to make a wake — both name dissipation, model limit, the stokes layer
- The better tunnel needs the bigger tank — both name damping, model limit, oscillation
- The gas sets a squeeze film's loss, not its stiffness — both name damping, dissipation, model limit
- The heat of a squeeze leaves across the gap — both name damping, dissipation, model limit
- A ball that bounces in water and not in oil — both name dissipation, model limit
Named objects
A dashed tag is an object no other essay names yet.
Contact angleDampingDissipationFroude numberModel limitOscillationScale effectSimilarityThe Stokes layer