In the lab the liquid runs into the bubble's edge head on; riding with the bubble it flows round a cylinder. Streamlines of the liquid around a circular bubble in a Hele-Shaw cell, upper half. Left, in the lab frame, the liquid moving at U far away: every streamline meets the bubble's edge at right angles, because the edge is a line of constant pressure. Right, in the frame of the bubble, moving at 2U: the same flow is uniform flow past a solid cylinder at speed U, and the edge is a streamline. Ideal flow

A bubble between two plates runs at twice the liquid

Squeeze a bubble between two glass plates a fraction of a millimetre apart and push liquid past it. The bubble does not drift with the liquid. It runs ahead of it at exactly twice the liquid's speed, whatever its size, whatever the liquid's viscosity and however wide the gap — and an elliptical bubble runs at one plus its length over its width. The reason is that the flow between the plates is a potential flow whose potential is the pressure, and a bubble, with one pressure inside it, is a conductor in a uniform field.

A turbulent layer fills the pipe in tens of diameters, and a tenfold Reynolds number only stretches that by 1.8. The boundary layer's thickness over the pipe's radius against distance from the inlet in diameters, at Reynolds numbers of 10⁴, 10⁵ and 10⁶. It reaches the centre at 14, 24.9 and 44.3 diameters. Near the inlet it grows as distance to the four-fifths, the flat plate's turbulent law. Viscosity

A turbulent pipe forgets its inlet as the quarter power

A laminar pipe flow takes a distance proportional to its Reynolds number to forget how it entered: five thousand diameters at a Reynolds number of a hundred thousand. A turbulent one at the same Reynolds number forgets in twenty-five. The difference is not a correction to the laminar answer but a different mechanism — a layer that grows by eddies rather than by diffusion — and the same momentum balance that gives the laminar length gives the turbulent one as 1.40 times the quarter power of the Reynolds number, so a tenfold faster flow needs only 1.8 times the length.

A modest spread of heights barely smooths Nikuradse's dip; Colebrook's curve needs heights spread over two decades. The roughness function ΔU⁺ against the equivalent sand roughness in wall units, for log-normal populations each element of which follows Nikuradse's own transition, their shifts added by area: σ = 0 (uniform sand), 0.47, 1 and 2.2, with Colebrook's function. A spread of 0.47 is still 1.76 below Colebrook's at its worst; 2.2 fits it to 0.18 everywhere. Transition and turbulence

The Moody chart would need a wall spread over two decades

Nikuradse's uniform sand stays smooth until its grains poke through the viscous sublayer and then dips before it rises. Colebrook's commercial pipes, on which the Moody chart is drawn, feel their roughness from the first fraction of a wall unit and never dip. The natural explanation is that a commercial wall is a population of heights, and the tall ones start early. Built element by element from Nikuradse's own transition, a population reproduces Colebrook's curve only if its heights span a factor of eighty between the middle two-thirds of the elements — and measurements of real pipes since 2006 suggest they do not.

One grain's balance of moments reproduces the dip in Shields' curve, and runs high for fine sand. Critical Shields number against the dimensionless grain size D⋆, for quartz in water: the force balance on a sphere with a pocket angle of 53.9°, chosen so the coarse limit is Soulsby and Whitehouse's 0.055, and their fit to the measured curve. The balance's minimum is 0.0279 near D⋆ = 25, a 1 mm grain, where the fit's is about 0.030; at D⋆ = 2.5, a 0.1 mm sand, the balance gives 0.131 against the fit's 0.0771. Regimes and numbers

A grain moves when its drag tips it out of its pocket

In 1936 Albert Shields measured the stress a stream must exert on its bed before the grains start to move, and found that a single dimensionless number, the stress over the grains' submerged weight per unit area, decides it — about 0.055 for coarse gravel, falling to 0.03 for coarse sand and rising again for fine. The dip and the rise come from one place. A fine grain sits inside the viscous sublayer, in slow smooth-wall flow, and needs a larger stress to feel enough of it; a coarse grain stands in the logarithmic layer and feels the full speed. A balance of moments on a single sphere in a pocket of spheres reproduces the dip and puts it in the right place.

Below a slope of three the horizon saturates; at three it climbs by a fixed step per decade of precision. The time for an error to climb from a stated scale to the largest, in largest-eddy turnover times, against the initial error's wavenumber over the largest's. For p = 5/3 it is 2.68 from a thousandth of the largest scale and 2.702 from a ten-millionth, the limit being 2.702. For p = 3 it grows by 3.32 per decade without end; for p = 11/3 faster still. What is taught wrongly

A forecast's horizon is set by the slope of the spectrum

A better measurement of today's weather buys a better forecast, everyone assumes, and with a single chaotic oscillator it does: every tenfold improvement in precision buys the same extra time. A flow with many scales of motion is different, and how different depends on one number, the slope of its energy spectrum. Shallower than k⁻³, the small eddies are so quick that an error in them reaches the large scales in a fixed time however small it starts, and perfect data buy a finite horizon. At exactly k⁻³ the logarithm comes back. The atmosphere's spectrum is steep at large scales and shallow at small ones, and that shape is why its horizon is about two weeks.

A row that can be bypassed peaks at 0.798, with four tenths of each strip blocked. The best power a turbine can take, as a fraction of ½ρU³ times its own area, against the share of its own strip it blocks, for a row standing in an unbounded stream; beside it the full fence across a channel at the same blockage, (16/27)/(1 − ε)², and Betz's 16/27. The row rises above Betz to 0.798 at a local blockage of 0.4, then falls: at 0.9 it is back to 0.632. Fluids at work

A row across part of a strait does best with four tenths of it blocked

Walls let a single turbine beat Betz without limit, and the neighbours in a row of turbines are walls of a sort. But a row that does not span its channel can be gone round as a whole, and that changes the answer completely. Each turbine's best rises above Betz only to 0.798, when the turbines block four tenths of the water between them, and falls again as they are packed tighter. The row as a whole, measured on its own outline, never beats Betz at all.

Holding the angle below stall gathers the best Strouhal number into a band a plunge spreads across. The Strouhal number of best net efficiency against the drag coefficient to be paid, on the plate's own area, at a plunge of 0.75 chords: the plunge alone, and pitched to hold the largest angle at 15°, 20° and 25°. Across drags from 0.01 to 0.2 the plunge alone's best runs from 0.074 to 0.62; held at 20° it runs from 0.26 to 0.57. Animals cruise between 0.2 and 0.4. Regimes and numbers

A plate held below stall keeps its best Strouhal number in the band

A plain plunging plate finds a best Strouhal number once it has drag to pay, but at that best it meets the stream at forty degrees, far past stall, and its best moves sixfold as the drag changes. Pitch the plate as it plunges, enough to hold its largest angle at twenty degrees, and Garrick's same exact theory says three things change at once: the efficiency rises, the best Strouhal number moves up, and it stops depending much on anything — not on the stroke, and only mildly on the drag. The band animals cruise in is what a flapper looks like when it refuses to stall.

Beside mid-chord, the error is a function of the gap over the panel size and nothing else. The size of the lift error, panels against the exact linearised lift, for a flat plate with a free vortex under its mid-chord, against the vortex's distance from the plate divided by the panel length, for 8 to 128 panels. The five curves lie on one another: 8.7 per cent at half a panel, 0.38 per cent at one. The dip near two panels is where the error changes sign; past it the error is below a quarter of a per cent for every count from 8 up, and the curves part, because a gap of several panels is no longer small against the chord. Circulation and lift

A panel can live with a neighbour one panel away, except at the edge

A lumped-vortex panel is exact for any onset flow that varies linearly across it, and a neighbouring vortex makes the onset flow curve over a length equal to its distance. So the natural rule is that a panel should be no longer than the gap to the nearest neighbour, and beside the middle of a chord that rule is exactly right: the lift error depends on the gap over the panel length and on nothing else, a third of a per cent when the two are equal. Under the leading edge the rule fails, and the reason is the edge's own singularity rather than anything about the neighbour.

Shaped for its cruise lift, the pair pays exactly a flat plate's drag due to lift there, and pays something at zero lift. Wave drag against lift at Mach 1.944, per unit of one element's chord, for the pair designed for 2° and the tilted symmetric pair, beside a single flat plate carrying the same lift, whose drag is β/4 times the square of its lift coefficient, and a diamond 6 per cent thick. At the design lift, 0.0838, the designed pair's drag is 0.002924, the flat plate's exactly; the tilted pair's is 0.003286. At zero lift the designed pair has a drag of 5.71·10⁻⁴ where the symmetric pair has none. Compressible flow

A Busemann pair shaped for its cruise pays a flat plate's drag and no more

Tilt Busemann's biplane to make it lift and its channel stops cancelling its own waves: the lift is still all on the outer faces, but the inner faces now cost drag. Reshape the two elements for the incidence they will cruise at — the lower apex moved forward, the upper apex aft, the upper element set ahead of the lower — and the channel at that incidence is Busemann's cancelling channel again, seen from the stream. Its drag due to lift falls to exactly what a single flat plate pays for the same lift, the least a two-dimensional section can pay in linear theory. The price is a drag at zero lift, a narrower Mach bucket, and a starting Mach number that falls to the design Mach number itself.