A row across part of a strait does best with four tenths of it blocked
Worth reading first: Walls let a turbine beat Betz, and the channel takes it back · The most a disc can take.
Walls let a turbine beat Betz, and the channel takes it back worked out what happens to the most a disc can take when the stream cannot go round the disc. Between rigid walls, with the flow held fixed, the limit is divided by the square of the share of the channel left open, and that grows without bound as the disc fills the channel. The extra power comes from a pressure drop the walls force across the whole channel, which a real channel driven by a tide can only supply by carrying less water.
That calculation had a fence in it: a row of turbines from bank to bank, so that every drop of water had to pass either through a turbine or through the gaps between them. Real tidal installations are rarely like that. A row of turbines across part of a strait, or a short line of them in the open sea off a headland, has water beside it as well as between its turbines. Each turbine still has neighbours, and to the water squeezing between two neighbours they look very much like walls. But the row as a whole is now an obstacle with ends, and the stream can go round it.
The question here is what that does to the bound. The answer was worked out by Takafumi Nishino and Richard Willden in 2012, and it is one of the more instructive results in the subject, because it says that the neighbours help each turbine up to a point and then start to hurt, and that the row as a whole is held to Betz’s limit after all.
Two blockages, one inside the other
The model needs two numbers where the fence needed one. Each turbine of area sits in a strip of the row whose width is the spacing between turbines. The share of its own strip it blocks is the local blockage , which is what the neighbours control. The row as a whole occupies some share of the channel it stands in, and that is the global blockage , which is zero for a row in open water. The fence of the previous calculation is the special case in which the row runs from bank to bank: there the row’s strips are the whole channel and the two blockages coincide.
Nishino and Willden’s step is to treat the two flows as separate in scale. Inside the row, the water passing through each turbine and the water squeezing between neighbours meet again and mix within a few spacings downstream. The flow round the row as a whole bends over a distance set by the row’s length, which is many spacings. So the flow is modelled as two actuator discs, one inside the other:
- at the device scale, each turbine is a fenced disc at blockage , exactly as Garrett and Cummins solved it, in an approaching stream whose speed is not the free stream but whatever speed the stream has when it arrives at the row;
- at the array scale, the row is a single disc in the stream , at blockage , whose thrust is the sum of the turbines’ thrusts and whose disc speed is .
The two are tied by one condition. Writing for each turbine’s thrust coefficient on its own arriving stream, the row’s thrust per unit of its frontal area, as a coefficient on the free stream, is ; and for a disc in open water the thrust coefficient and the disc speed are tied by the familiar . With ,
Each turbine’s power, on , is then its fenced coefficient on its own stream times the cube of the speed that stream arrives with:
The one free choice is how hard each turbine is loaded, which the model expresses as the speed at which its own wake leaves, and the best power at each local blockage is found by a search over it.
The peak, and the fall after it
The search lands where Nishino and Willden said it would. With no turbines in the row, and the fenced disc at zero blockage is the open disc, so the curve starts at . As the local blockage rises, each turbine’s own fenced coefficient rises steeply, exactly as in the fence; but the row’s thrust rises with it, and falls. The two meet at a maximum of 0.7976 at a local blockage of 0.404, against the published 0.798 at about 0.4. Past it the arriving speed is falling faster than the fenced coefficient is rising, and by a local blockage of 0.9 the best power is 0.632, barely above Betz.
The curve the fence draws at the same blockage is the dashed one, and the gap between them is the whole of this essay. At a local blockage of 0.4 a fence would allow 1.646, and a row in open water allows 0.798. The neighbours are walls only to the water that has already arrived at the row; whether the water arrives is decided by the row as a whole, and a row is an obstacle that can be gone round.
The speeds make the mechanism visible. The stream reaches the row at 0.824 of its free speed at the peak and at 0.678 when the turbines block nine tenths of each strip: a third of the water that would have crossed the row’s outline has gone round its ends or over it instead. Inside the row, each turbine slows its own arriving stream to 0.673 of it, so the water through a turbine moves at 0.555 of the free stream. That is lower than the open disc’s two thirds, and lower still than the 0.476 the fenced disc at the same blockage would pass. A turbine in a row is a disc inside a disc, and both discs slow the water.
The design that a fence would choose
The fence had a curious property, recorded in the essay on it: at every blockage, the best design leaves its core wake at exactly a third of the stream. That is Betz’s wake speed, and its survival through the walls looked like a law. It is not one here.
At the peak the best turbine in a row leaves its wake at 0.51 of its own arriving stream, not a third, and at a local blockage of 0.9 at 0.94 of it — barely slowing the water at all. The row’s best turbines run much lighter than a fence’s, because every extra newton of thrust a turbine adds is also thrust the row as a whole exerts, and the row’s thrust is what pushes the stream round its ends.
The cost of getting that wrong is large. A designer who knew the fence result and loaded each turbine to Betz’s third would take 0.676 instead of 0.798 at a local blockage of 0.4 — a sixth of the available power gone — and 0.292 instead of 0.756 at 0.6, which is less than half of an isolated turbine’s Betz limit. At high local blockage the fenced design’s thrust is so large that the row behaves almost as a solid wall in the stream, and a solid wall in an open stream receives almost no flow. This is the same lesson a loss with no viscosity in it draws for a sudden expansion in a pipe, turned round: a resistance placed in a stream that has an alternative path does not get the pressure drop it asks for, it gets a share of the flow set by the alternative.
Each turbine beats Betz, and the row never does
The most useful number for a developer is not the power per turbine but the power per metre of row, because the width of a strait and the depth of its water are fixed and the number of turbines is a choice. Per unit of the row’s whole frontal area, the power is the per-turbine coefficient times the local blockage, and that behaves quite differently.
The row’s power on its own outline rises monotonically, through 0.319 at the peak of the per-turbine curve and 0.579 at a local blockage of 0.94, and its limit is exactly . That is not a coincidence, and it is the surprising connection in the result. As the turbines close up, the row becomes a single disc in an open stream, the device-scale mixing between neighbours vanishes because there is no water between them to mix with, and Betz’s original argument applies to the row itself. A partial row is an open disc, and an open disc cannot beat Betz on its own area however it is subdivided. The neighbours redistribute the row’s power among the turbines and raise each one’s share of it, but the row as a whole is bounded exactly as a single turbine in open water is.
So there are two different optima, and they answer two different questions. If turbines are expensive and the strait is wide, the developer wants the most power per turbine, which is the peak at four tenths. If the strait is narrow and the turbines cheap, the developer wants the most power per metre of row, which keeps rising as the row closes up and approaches Betz on the row. Neither of them gets the fence’s unbounded gain, because a fence needs the row to reach the banks.
When the row blocks part of the channel
The last parameter puts the banks back gradually. A row that occupies a tenth of a channel’s cross-section is still gone round, but less freely than in open water, and the array-scale disc is now itself a fenced disc at blockage , solved with Garrett and Cummins’s equations in place of the open disc’s .
The peak rises and moves to tighter spacing as the global blockage rises: 0.864 at a local blockage of 0.50 when the row blocks a tenth of the channel, 0.972 at 0.66 when it blocks a fifth, and 1.20 at the tightest spacing computed when it blocks three tenths. At that point the best row is a closed one, as it would be in a fence. The two limits are joined smoothly, and the one number that decides which regime a site is in is the global blockage: below a tenth or so, the row is effectively in open water and the four-tenths spacing is the right one; above a quarter, the banks have taken over.
Why the bypass matters more than the gaps
It is worth asking what the two scales of mixing cost, because the efficiency of the process — the turbines’ power as a share of what the stream loses — is where the row’s two discs show most plainly. In the fence, the turbine got its own disc speed’s worth of what the stream lost, two thirds in open water and 0.444 at a blockage of a half, and the rest went to heat in the mixing of the core wake with the bypass — the Borda–Carnot loss that mixing is a pump turns into a pressure rise. In a row there are two mixings: the turbine wakes with the water between neighbours, a few spacings downstream, and the row’s whole wake with the stream that went round it, much further downstream. The turbines’ share is the product of the two disc speeds, 0.555 at the peak.
That share falls from two thirds to 0.553 near a local blockage of 0.3 and rises again to 0.657 at 0.94, as the device-scale mixing disappears with the gaps. A tight row wastes little between its turbines because there is little between them; a moderately packed row pays for both mixings and is the least efficient arrangement of all, even though it is the one that takes the most power per turbine. The peak is a compromise between extracting hard and wasting little, and in that it is the same compromise as Betz’s, made twice.
The thrust tells the same story. On its own arriving stream each turbine’s thrust coefficient at the peak is 2.11, much more than Betz’s , because each turbine pushes against water its neighbours have already crowded towards it. On the free stream, the same thrust is a coefficient of 1.44, and at a local blockage of 0.9 only 0.971: the row’s best design cannot push the stream much harder than a single open disc does, because the stream can always decline. It is the trade a big slow push described for a propeller, with the sign reversed: a turbine that pushes a lot of water a little is better than one that pushes a little water a lot, and a row cannot choose how much water it is offered.
What a tank test does to the number
This result also explains a difficulty in testing. A model turbine in a towing tank or a flume is in a channel, with the tank’s walls at some blockage — the turbine’s counterpart of the wing in the walls are in the answer — and one coefficient, two errors showed how a wind tunnel’s walls bias a wing’s lift in two directions at once. Here the walls bias a turbine’s power upward, and the correction depends on which situation the full-scale turbine will be in. A turbine destined for the middle of a long row in a narrow strait should be corrected towards a fence; one destined for a short row off a headland should be corrected towards the two-scale curve, which at the same local spacing gives a power well below the fence’s. Correcting a tank result to open water, as is usual, answers a question nobody building a row is asking.
The convention the numbers are in
Every power coefficient is on , with the undisturbed stream far upstream and one turbine’s swept area; every thrust coefficient on the free stream is on , and on the turbine’s own stream on . The local blockage is a turbine’s area over its strip of the row; the global blockage is the row’s whole frontal area over the channel’s cross-section. The channel has a rigid lid, so the free surface does not drop across the row — the low-Froude-number limit — and the flow is steady and uniform upstream.
What was checked, and what was not
The empty row returns Betz to six digits. The peak, searched over both the loading and the spacing, is 0.7976 at a local blockage of 0.404, against Nishino and Willden’s 0.798 at about 0.4; that is the published comparison, and it tests the whole chain, since both scales have to be right for it to land. Each design satisfies the array balance it was solved from to , and the open row’s thrust and arrival speed obey the open disc’s momentum relation exactly. The device scale is the fenced-disc solution already checked against Garrett and Cummins’s closed form to fifteen digits.
What was not checked is the scale separation itself. The model assumes the strips mix out before the row’s own flow has finished bending, which needs a row many spacings long. A row of four turbines is not that, and the correction for a short row is not small. Nor was any effect of the free surface included: in a real strait the surface drops across the row, by an amount set by the Froude number, and the drop changes both discs’ momentum balances. Both were treated by later work, and both lower the numbers somewhat.
What the picture cannot show
The actuator disc is an idealisation at both scales. A turbine is not a disc but a rotor, with a swirling wake and tip losses, and the wake that has to spin priced what the swirl costs; a row of real rotors would reach a smaller fraction of 0.798 than a single rotor reaches of Betz. The mixing that the model places conveniently far downstream is turbulent, and its rate decides whether the scales really separate. And the tidal flow is not steady: it reverses twice a day and varies in strength, so a row’s spacing is chosen once for a range of flows, while the optimum loading changes with each. None of this moves the shape of the result — a peak per turbine and a monotonic rise per row — but all of it moves the numbers.
Who found it and the argument it settled
Garrett and Cummins’s fenced disc appeared in 2007, and the obvious reading of it — that blockage is a free gift to tidal energy — lasted only until people asked about rows that did not span their channels. Nishino and Willden’s paper, “The efficiency of an array of tidal turbines partially blocking a wide channel”, appeared in the Journal of Fluid Mechanics in 2012 and introduced the two-scale model used here; the figure 0.798 is theirs. The connection to the ducted turbines of a duct beats Betz only on the area it chooses is close: there too the gain over Betz turned out to be an artefact of which area the coefficient was referred to, and here the row’s outline plays the part the duct’s exit played. Measured on the right area, nothing beats Betz in open water.
Still open: the row that is also a weir
The rigid lid is the model’s most convenient fiction. In a real strait the surface falls across a row, and at higher Froude numbers the drop is a substantial part of the head available; the row then behaves partly as a weir, and a weir’s flow is set by its crest rather than by momentum alone. Vogel, Houlsby and Willden extended the fenced disc to a deformable surface and found the bound rising with the Froude number.
The calculation that would follow puts the free surface into both scales of the two-scale model — a surface drop across each turbine’s strip and another across the row — and asks how the peak’s position and height move with the channel’s Froude number, whether the four-tenths spacing survives at the Froude numbers of the fast straits where tidal turbines are actually placed, and whether the row’s power on its outline can then exceed , since a surface that drops is a boundary that is not an open stream.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- A disc that knows no blades — both name actuator disc, the betz limit, efficiency, model limit, momentum theorem
- A duct is worth the square root of two — both name actuator disc, control volume, efficiency, model limit, momentum theorem
- Between hover and twice the hover inflow — both name actuator disc, the betz limit, control volume, model limit, momentum theorem
- The lower rotor spends its power in the upper rotor's wake — both name actuator disc, control volume, efficiency, model limit, momentum theorem
- Work out of a change of swirl — both name control volume, efficiency, model limit, momentum theorem
- A pump with no engine — both name control volume, efficiency, model limit
Named objects
A dashed tag is an object no other essay names yet.
Actuator discThe Betz limitBlockageControl volumeEfficiencyMixingModel limitMomentum theorem