Walls let a turbine beat Betz, and the channel takes it back
Worth reading first: The most a disc can take · A duct beats Betz only on the area it chooses.
The most a disc can take is one of the few results in this subject that engineers quote as a law. A disc that drops the pressure of the fluid crossing it, set in a stream that is free to go round it, can take at most 16/27 of the kinetic power that would have flowed through its area had it not been there. The bound has two halves that pull against each other. Slow the flow hard, and each kilogram gives up a lot of energy, but fewer kilograms arrive because the stream sidesteps the obstruction. Slow it gently, and plenty arrives with little to give. The compromise slows the far wake to a third of the wind and passes air through the disc at two-thirds of it.
Nothing in that argument mentions a wall, and the stream’s freedom to go round is half of it. A tidal turbine in a narrow strait, a river turbine in a canal and a model rotor in a water flume are not in an unbounded stream. Their surroundings stop at a bank, a bed and a surface, and a flow that cannot go round can only go through. The question here is what happens to the limit when the walls are put back, and the answer has two parts that are easily confused. The first is a calculation by Chris Garrett and Patrick Cummins, published in 2007, and it says the walls raise the limit without bound. The second is an earlier calculation of theirs, from 2005, and it says that a real channel takes most of that back.
Putting the walls back
The model is the open disc’s with one change. The disc has area and sits in a channel of cross-section ; their ratio is the blockage. The channel has a rigid lid as well as rigid walls, so its cross-section cannot change, and upstream the flow is uniform at speed . Downstream of the disc the flow divides into two streams that run side by side before they mix: a core wake of the fluid that passed through the disc, moving at , and a bypass of the fluid that went round it, moving at . Once their streamlines are straight again they share one pressure, .
Four statements fix everything. Mass is conserved across the channel:
where is the speed through the disc and the bracket is the area the bypass occupies once the wake has expanded to carry its flow at . Bernoulli’s equation holds along the bypass, which has done no work, so . It holds on either side of the disc too, and subtracting the two gives the thrust as . Finally the momentum of the whole channel between upstream and the station where the two streams are side by side balances the pressure difference against the thrust. Those four leave one free parameter, and the natural one is the wake speed . For each value of it the momentum balance fixes , the thrust follows, and the power is .
That is a computation, and the figure above is its result: for each blockage, a search over every wake speed between zero and the stream’s for the one that gives the most power. The search knows nothing of a formula. What it finds is that the best power coefficient, measured as Betz measured it, is
to fifteen significant figures at all six blockages checked. That is Garrett and Cummins’s closed form, and at it is Betz’s own number. At a blockage of a tenth the bound is already 0.732, a quarter above the open-water limit. At three tenths it is 1.21. At a half, 2.37: a disc taking more than twice the kinetic power that flows through its own area.
Nothing has been violated
A coefficient above one looks like an error, and it is worth saying exactly why it is not one. The open-water limit is quoted against the kinetic power that would have crossed the disc’s area at the undisturbed speed, . That is a convenient reference, not a budget. In open water it happens to be close to the real budget, because the stream sidesteps the disc and the far field is untouched. In a channel at a fixed flow rate the far field is touched. The flow cannot sidestep, so something upstream must push harder to keep the same flow going through a channel that now has an obstruction in it, and the push shows up as a drop in pressure from one end of the turbine’s reach to the other.
That drop acts over the whole channel, not over the disc. It is a head, and it is paid by whatever keeps the flow rate constant. Measured as a fraction of the dynamic pressure, the head drop across the fence at the optimum is , which is 0.12 at a blockage of a tenth, a third at a fifth and 2.67 at a half. The turbine’s extra power is that head times the flow, less what is lost on the way. So the coefficient above one is a statement that the disc is no longer drawing only on the energy carried through it. It is drawing on a pressure difference that the walls make it possible to sustain.
The comparison that removes the paradox is per unit of channel, not per unit of disc. Multiplying the coefficient by the blockage gives the power as a fraction of , the kinetic flux of the whole channel. It is 0.073 at a tenth, 0.185 at a fifth, 0.363 at three tenths and 1.19 at a half. The last number is above one, which is the same statement again from a different side: once the fence spans half the channel, the turbines are taking more than all the kinetic energy the channel carries, and the balance has to be coming from the pressure.
The wake still leaves at a third
The search returns more than the peak. It returns where the peak is, and that turns out to be the most surprising thing in the calculation.
In open water Betz’s best wake leaves at a third of the stream’s speed. With walls, the search finds the best wake leaving at a third of the stream’s speed again — at a blockage of a tenth, of three tenths and of a half, to the precision of the search. The whole family of curves rises as the walls close in, and every member peaks at the same place. That fact is not obvious from the equations, which mix the three speeds in a way that looks as though any blockage ought to shift the optimum. It is however what makes the closed form possible, and it gives a clean way to read the result: the walls do not change how hard the disc should slow the fluid that goes through it. They change how much of that fluid there is and what pressure it is slowed against.
What does move is the speed through the disc itself. In open water it is two-thirds of the stream. With walls it falls as : 0.606 at a tenth, 0.556 at a fifth, 0.513 at three tenths, 0.444 at a half. The disc is passing less fluid per unit area than before, while the wake behind it is as slow as ever. And the bypass, the water that went round, speeds up — as , which is 1.15 times the stream at a tenth and 2.33 times it at a half.
That fast bypass is where the extra power comes from, though the turbine never touches it. Bernoulli’s equation along the bypass says that fluid moving at 2.33 times the stream speed is at a far lower pressure than the stream upstream. That low pressure is the pressure behind the disc as well, because the wake and the bypass run side by side at one pressure. So the disc works against a back pressure that the bypass has lowered for it. The pressure difference across the disc, which is the whole of its thrust per unit area, is set by how fast the water beside the wake is moving, and the walls are what make the water beside the wake move fast. It is the same mechanism by which a duct with a suction at its exit beat the open limit on its rotor area, with the channel’s bypass playing the role of the duct’s outer flow. There the suction had to be bought with a flared shroud. Here the channel provides it for nothing, because the bypass has nowhere else to go.
Where the extra power goes before it arrives
The fast bypass and the slow wake cannot stay side by side for ever. They mix, and mixing two streams at different speeds in a constant-area channel loses total pressure. That loss is exactly the one a sudden expansion pays with no viscosity in it: a momentum balance between the unmixed station and the fully mixed one fixes the pressure rise, Bernoulli would have predicted a larger one, and the difference is energy turned into heat in the mixing layer, however small the viscosity.
A momentum balance between the far upstream station and a far downstream one where the flow is uniform again gives the total pressure lost by the stream as . The stream therefore loses power at the rate , and the turbine takes of it. The turbine’s share of what the stream loses is simply the ratio of the speed through the disc to the stream’s speed, whatever the blockage. In open water that is two-thirds, and a third of the power removed from the wind goes into mixing the wake back into the free stream. At a blockage of a fifth the turbine’s share is 0.556 and the mixing’s is 0.444. At a half the turbine gets 0.444 and the mixing 0.556: more power is destroyed behind the fence than generated by it.
So the walls buy a larger turbine output at a worsening exchange rate. That matters in a tidal channel, where the quantity a project is limited by is not the turbine’s coefficient but the channel’s total loss, because the channel’s total loss is what changes the tide. The same arithmetic says that a fence with a large blockage is an efficient way to slow a channel and an inefficient way to generate power from it. The bypass is fast because the disc is in the way, and the energy that makes it fast is mostly given back as turbulence downstream rather than through the shaft.
The flow is not fixed
Everything so far assumed a fixed flow rate. The upstream speed was a given, and the head drop across the fence was whatever it had to be to keep fixed. That is the right model for a turbine in a flume driven by a pump with a steep characteristic, and for a turbine whose fence spans a small part of a large channel. It is the wrong model for a strait connecting two seas, where what is given is the difference in water level between the ends, set by the tides outside, and the flow through the strait is whatever that head can drive against the strait’s resistance.
Garrett and Cummins had addressed that case two years before the fenced-disc paper. The essential piece survives a stripped version of it. Suppose the channel’s own friction is quadratic, so a head drives a flow with . Turbines add a second resistance of the same form, . The flow then falls to , where , and the power the turbines remove from the flow is .
That power has a maximum, and it is at : when the turbines’ resistance is twice the channel’s own. There the power is of , the head times the undisturbed flow, and the flow has fallen to , 58 per cent of what it was. Push harder and the power falls, because the flow falls faster than the resistance rises. In a tide the head varies as ; if the flow follows it without lag, the power averaged over a cycle is 0.385 times the mean of , which a quadrature gives as 0.556, so the mean power is 0.214 . Garrett and Cummins kept the channel’s inertia as well as its friction and found a coefficient between about 0.20 and 0.24 depending on which dominates, with 0.22 as a working value. The frictional limit sits inside their range.
Now the two calculations can be put together, and they say different things. The fenced-disc limit says that a turbine fence across a channel can be far better than Betz for a given flow. The channel limit says that the flow is not given: any power taken out of the channel reduces the flow through it, and the most that can be taken from the whole channel is fixed by the head and the undisturbed flow, however the turbines are arranged. A larger blockage makes each turbine better and the channel no richer. What the blockage changes is the share of the channel’s maximum that ends up in the shafts rather than in the mixing behind them — which is the share the previous figure drew.
What was checked, and what was not
The search was checked against the closed form at six blockages, from zero to a half, and the worst relative error is . At zero blockage it returns Betz exactly: a power coefficient of 16/27 at a wake speed of a third and a disc speed of two-thirds. Mass conservation holds at every state the search visits to twelve figures. The channel’s best resistance ratio was found by a sweep at a step of a thousandth and lands on two; the tidal mean of was found by quadrature and not from a table.
What none of this checks is the model’s form. A rigid lid is the first idealisation and the largest. A real tidal channel has a free surface, and a fence that drops the pressure behind it drops the water level there too, so the bypass runs in a shallower section than the model allows. That changes the mass balance and adds a term. Whelan, Graham and Peiró worked the free-surface version in 2009 and found the limit rising further with the Froude number, which is the subject of the depth that costs least: a stream close to critical has very little room to drop its level without choking, and a jump becomes possible behind the fence.
The second is that the disc is a disc. It has no blades, no swirl and no tip losses, and it removes energy from every streamline crossing it equally. The wake that has to spin shows what swirl costs in open water, and nothing here says whether that cost scales with the blockage. The third is that a fence is not one disc: a row of turbines across a channel has gaps between them as well as above and below, and each turbine sees a local blockage within its own part of the row as well as the global one. Neither is captured by a single .
The convention the numbers depend on
Three numbers in this essay have the same name and different meanings, and every claim that a device “beats Betz” depends on which is meant.
The power coefficient is power divided by , and the choice of and of decides its value. Here is the disc’s area and is the speed far upstream with the flow rate held fixed. That is the convention under which the limit rises above one. Measured against the channel’s area instead, the same optimum is times smaller and never exceeds the head’s contribution. Measured at a fixed head rather than a fixed flow, the coefficient is not even well defined until the channel’s resistance is stated. A turbine tested in a flume at 30 per cent blockage, reported against its own area and the flume’s speed, can show a coefficient above 0.8 for reasons that have nothing to do with the turbine. The walls are in the answer made the same point about a wind tunnel’s corrections: the box is part of the measurement, and a result that does not state the box is a result about the box.
There is a fourth sense in which a ducted or fenced turbine can be said to beat Betz, and it is the one that matters commercially: power per unit of something that costs money. That is a different question, and nothing in a momentum argument answers it.
Two papers and a disagreement that was not one
Lanchester in 1915 and Betz in 1920 each derived the open limit, and Joukowsky had it in Moscow by about 1920 as well. The channel version waited eighty years, until tidal power made it worth having. Chris Garrett and Patrick Cummins published the channel-budget paper, “The power potential of tidal currents in channels”, in the Proceedings of the Royal Society in 2005, and the fenced-disc paper, “The efficiency of a turbine in a tidal channel”, in the Journal of Fluid Mechanics in 2007. The second answered a question raised by the first: if the most a channel can give is , how much of that can turbines actually collect? Their answer was that a turbine fence spanning the whole channel collects two-thirds of the power lost from the flow at small blockage, the rest going into wake mixing, and less as the blockage rises — the efficiency curve drawn above. Houlsby, Draper and Oldfield, and Whelan, Graham and Peiró, extended it to a free surface within the next two years.
The two results are sometimes quoted as though they disagreed — one says the limit rises without bound, the other says a channel has a fixed maximum. They answer different questions. The first is about a turbine, with the flow given; the second is about a channel, with the head given. The resemblance to the ejector, where mixing is the pump rather than the loss, is not accidental: in both, the interesting physics is in two streams at different speeds sharing one pressure, and the only difference is which way the energy flows.
Still open: how much of the bound a row of real turbines reaches
The fence here spans the channel. Real installations do not: a row of turbines across part of a strait is a partial fence, with flow able to go round the row’s ends as well as between and over its turbines. Each turbine then sees two blockages — a local one, its own area against the strip of channel its neighbours confine it to, and a global one, the row against the whole strait. The local blockage raises each turbine’s coefficient in the way computed here; the global one is weak, because the row can be bypassed at its ends.
The calculation that would settle it nests the model inside itself: an inner fenced disc at the local blockage, whose thrust then acts as a single porous plate in an outer fenced problem at the row’s global blockage, with the mixing of the inner wakes completed before the outer one begins. It would ask how the best power per turbine depends on the two blockages together, and in particular whether there is a row length beyond which adding turbines raises the total by less than the extra turbines’ share — which is the number a strait’s layout is decided by. Whether the inner and outer mixings really separate in scale, as the nesting assumes, is the part of the calculation that a one-dimensional model cannot check on its own, and it is where the way an extra branch can cut a flow suggests a counterintuitive answer may be waiting.
What links here
Computed from the collection rather than written here: the essays that point at this one.
Reads more easily once this is understood
Essays that name this one as worth reading first.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- A disc that knows no blades — both name actuator disc, the betz limit, efficiency, model limit, momentum theorem
- A duct is worth the square root of two — both name actuator disc, control volume, efficiency, model limit, momentum theorem
- Between hover and twice the hover inflow — both name actuator disc, the betz limit, control volume, model limit, momentum theorem
- The lower rotor spends its power in the upper rotor's wake — both name actuator disc, control volume, efficiency, model limit, momentum theorem
- Work out of a change of swirl — both name control volume, efficiency, model limit, momentum theorem
- A big slow push — both name actuator disc, control volume, efficiency
Named objects
A dashed tag is an object no other essay names yet.
Actuator discThe Betz limitBlockageControl volumeEfficiencyMixingModel limitMomentum theorem