Concept

Nusselt number — where it appears

The ratio of the heat a fluid carries away from a wall by flow to the heat conduction alone would carry across the same length. It is the dimensionless heat transfer coefficient, and its developed value in a pipe depends only on the flow and the wall's condition.

Named by 6 essays across one field — each of them below, with the objects they name alongside it.

The number a duct settles at is an eigenvalue. The local Nusselt number against x⁺ = x/(D·Re·Pr), from a Crank–Nicolson march that contains no eigenvalue anywhere. It settles at 3.6568, which is λ₀²/2 for the Graetz eigenvalue problem — a completely separate calculation. The mark at x⁺ = 0.05 is the entry length every textbook quotes: it delivers a Nusselt number 1.45 per cent above the developed value, which is a perfectly reasonable tolerance and is never the one stated.

How far before the heat arrives

A duct's thermal entry length is quoted everywhere as x/(D·Re·Pr) = 0.05, with no tolerance attached. Working out what it delivers gives a Nusselt number 1.45 per cent above the developed value — and the developed value itself is not a term ratio at all but an eigenvalue, 3.6568, which is also the rate at which the duct forgets its inlet.

regimes · Peclet
The entrance grows with the Péclet number, peaks, and then shrinks. The distance from a wall-temperature step at which the local Nusselt number has come within 5 per cent of its developed value, in diameters, against the Péclet number, for turbulent pipes at Reτ = 500, 1000, 2000 and 5000, with the slug's laminar line L/D = 0.029·Pe. The liquid metals sit on the line; the entrance peaks at 11.6 diameters at Pe ≈ 4700 for Reτ = 1000 and falls to about three and a half diameters for water.

The longest thermal entrance belongs to neither metal nor gas

A liquid metal carries its heat across a turbulent pipe by conduction, as a laminar flow would, and so its thermal entrance should be long. It is long only when its Péclet number is large. Below a few hundred the entrance grows in proportion to the Péclet number with the constant of a fluid moving as a solid block, and it leaves that scaling close to the threshold at which the eddies first match conduction. The longest entrance in a turbulent pipe belongs to the fluids between the metals and the gases, and how long it is depends on a number the measurements have never pinned down.

regimes · Peclet
A resistive wall lengthens a slug's thermal entrance by half, and no more. The 5 per cent thermal entrance length of a slug flow, as a multiple of its length with the wall held at a fixed temperature, against the wall Biot number hw·D/kf. A wall that conducts well changes nothing; as the wall's resistance grows the entrance lengthens to a peak of 1.501 times at a Biot number of 2.29, and then shortens slightly to 1.457 times, the fixed-flux value, for a wall that conducts hardly at all.

A steel wall lengthens a sodium entrance by half

A liquid metal's thermal entrance is long because its heat crosses the pipe by conduction, and a steel tube conducts a tenth as well as sodium, so the wall is part of the path. Put it in series with the fluid and the entrance does grow — but by half at the very most, at a wall Biot number near two, which is where sodium in a steel tube happens to sit. A wall that resists more changes the boundary condition from a fixed temperature to a fixed flux, not the length.

regimes · Peclet
Each collapsed form of the plate's heat transfer reaches its limit decades away from air. The exact local Nusselt number of a vertical isothermal plate in its two collapsed forms against the Prandtl number: over (Gr·Pr²)^¼, which tends to Le Fevre's 0.600 as Pr → 0, and over (Gr·Pr)^¼, which tends to 0.503 as Pr → ∞. At Pr = 10⁻⁵ the first reads 0.5994; at 10⁵ the second reads 0.5023. The two limit laws cross at Pr = 0.494, where the exact value is 0.736 of either; air, at 0.72, reads 0.421 and 0.387.

Over a plate in mercury the warm layer flows as if inviscid

The exact solution for a warm vertical plate has been tabulated since 1953 and is usually shot from the wall, which fails in a liquid metal unless the shot starts within a thousandth of the answer. Posed instead as one algebraic system, it solves from a Prandtl number of a hundred-thousandth to a hundred thousand — and shows that in mercury the layer's speed is set without viscosity, that the integral method runs low there rather than high, and that air sits where neither limiting law is within a fifth.

regimes · Grashof
A flat plate's layer is pushed along by the pressure its own warmth leaves, strongest at the wall. Across the layer of a horizontal plate warm side up, in air: the velocity scaled to its peak, the temperature excess, and the along-plate push −∂p′/∂x scaled to its wall value, against the similarity distance η = (y/x)·Gr^⅕. The push is the hydrostatic deficit under the warm fluid, (2/5)(ηθ − P), 0.694 at the wall in units of gβΔT·Gr^−⅕, falling to nothing at the layer's edge; the velocity peaks at η = 1.58 and the warm layer ends near 5.93.

Laid flat, a warm plate is pushed by the pressure of its own layer

A warm vertical plate drives its layer with buoyancy acting along it. Lay the plate flat and buoyancy acts across the layer instead, so the only push along it is the pressure deficit its own warm fluid leaves under the cold — deeper where the layer is thicker. That push gives a heat transfer growing as the fifth root of the Grashof number, not the fourth, works only on the plate's upper face, and survives a tilt of a degree for a third of a metre.

regimes · Grashof
The film thickens down the wall as a fourth root, so most of the heat crosses near the top. The condensate film's thickness down a vertical wall 10 K below saturation in steam. It reaches 117 µm at half a metre, at a mean speed of 0.152 m/s and a film Reynolds number of 241. The local heat-transfer coefficient there is 5.81 kW/m²K, and the wall's mean 7.75.

A condensing film throttles itself by a fourth root

Steam meeting a cold wall condenses into a film of water, and the heat has to cross that film before any more can condense. So the more it condenses, the harder it gets. Nusselt wrote the balance in 1916, in a few lines with no fitted constants, and its answer is a heat-transfer coefficient that falls as the fourth root of the wall's height and the fourth root of the temperature drop: drive the wall harder and the coefficient gets worse. It is the rare Nusselt number that can be calculated outright, and it is a fifth too low, for a reason that took decades to name.

regimes · Nusselt

Named alongside it

The objects these essays reach for when they reach for this one.

Heat transferModel limitPrandtl numberEigenvaluePeclet numberBoundary layerBuoyancyEntry lengthGraetzSimilarity solutionThresholdAsymptotics

All concepts