Concept

Prandtl–Meyer expansion — where it appears

The function giving how much a supersonic flow turns as it accelerates isentropically round a convex corner. It is the exact solution of the expansion fan, and it says how far a flow may turn before its pressure would fall to nothing.

Named by 4 essays across one field — each of them below, with the objects they name alongside it.

The same 10° turn, taken both ways. A supersonic stream turned away from itself expands through a fan of Mach waves and keeps every bit of its total pressure. Turned into itself through the same angle it shocks, and pays. Nothing in the equations distinguishes the two cases except the sign of the angle: compression waves converge and steepen into a front, expansion waves diverge and spread.

Turning the other way is free

Compression through ten degrees at Mach 2 costs 1.54 per cent of the total pressure. Expansion through the same ten degrees costs exactly nothing — not approximately nothing, nothing — and the two are the same equations with the sign of one angle changed.

compressible · Expansion fan
The wall is what cancels the waves it made. The characteristic net of a minimum-length nozzle designed for Mach 2.4, with 18 waves. The pale lines run from the sharp throat down to the axis, reflect there by symmetry, and run back up to the wall; the wall turns through exactly the angle needed to cancel each one as it arrives, so nothing reflects back into the flow and the exit is uniform at Mach 2.400 and parallel to 0.0 degrees. The area ratio decides the Mach number and this net decides the shape, and the two agree on the exit height to 0.51 per cent at this resolution.

The wall that cancels its own waves

The area ratio of a supersonic nozzle fixes its exit Mach number and says nothing whatever about its shape. What fixes the shape is a wave-by-wave construction in which the wall turns through exactly the angle needed to absorb each expansion as it arrives — and getting it wrong leaves a stream full of oblique shocks at precisely the right Mach number.

compressible · Characteristics
So splitting a turn into N ramps costs one over N squared. A twelve-degree compression at Mach 3, done in one ramp and in up to sixty-four. The entropy is N times a cube of one Nth, so it falls as exactly the inverse square of the number of ramps — the measured exponent is −2.00 — and sixty-four ramps cost a two-hundred-and-fifty-sixth of what one costs.

A compression that costs nothing in the end

Turning a supersonic stream away from itself is free and turning it into itself is not. But the price of a compression is the cube of its strength, so splitting one turn into N turns costs one over N squared — and in the limit the compression is free too.

compressible · Expansion fan
At Mach 3 the cowl caps external compression at 88 per cent. Best recovery at Mach 3 against the number of oblique shocks, free and with the total turn capped at the free stream's detachment angle, 34.07°, which is as far as the cowl's outer surface can turn. Free, six shocks reach 94.2%; capped, 86.7%, and no number of shocks, nor a continuous isentropic ramp turning the same angle, can pass 88.5%.

The cowl caps what the ramps can buy

Every ramp in front of a supersonic intake turns the flow towards the cowl, and the cowl's outer surface has to turn the free stream at least as far. Past the free stream's own detachment angle it cannot, and that one angle caps every external intake: at Mach 3 no number of ramps, nor a smooth ramp, recovers more than 88 per cent, and the shock that is left at the throat is the strongest in the train. Above Mach 3 the cap falls fast, which is why fast intakes compress inside.

compressible · Oblique shock

Named alongside it

The objects these essays reach for when they reach for this one.

IsentropicTotal pressureCharacteristicsEntropyExpansion fanIrreversibilityMach numberModel limitOblique shockOptimisationShock waveArea mach

All concepts