A tip injector that saturates on noise gives back the stall line
Worth reading first: A compressor needs one actuator for each way it can fail · The plenum decides whether a compressor surges.
A compressor needs one actuator for each way it can fail: the throttle, sized by what a turning frame keeps of the rotor’s work, can hold off surge, the plenum’s oscillation, but it has one degree of freedom, and can hold the peak only in a small plenum; it cannot stop a rotating stall cell from starting. Air injected at the rotor tips, against the cell, can. The cell is the compressor’s own failure, the one the stress that picks the aerodynamics leaves a blade row closest to. In the Moore–Greitzer model the injector adds to the cell’s first-harmonic equation a term opposite to the cell, proportional to it with a gain , and the cell can then grow only where , being the flow’s distance from the peak in units of the characteristic’s half-width and the injector’s phase lag. A gain of 0.4 holds the machine to 0.887 of its peak flow; a gain of 0.7 to 0.774.
That calculation read the cell perfectly. A real controller infers the cell from a ring of wall-pressure sensors — six or eight in the experiments — each of which reads the cell’s pressure plus everything else: the blade-passing tone, turbulence, the electronics. When the cell is small, which is exactly when the injector must act, its harmonic is buried in that. The question is whether noise in the estimate spends the margin the noiseless injector bought, and the answer depends entirely on one property of the injector: whether it can blow as hard as it is asked.
An unbiased estimate, and why that is not enough
sensors equally spaced round the annulus at angles read , with and the cell’s amplitude and position and independent noise of standard deviation . The least-squares estimate of the cell’s first harmonic is
and it is unbiased: its average is the cell’s true harmonic , with a complex Gaussian error whose real and imaginary parts each have the standard deviation . An injector that blows in proportion to therefore delivers, on average, exactly what it would with a perfect sensor. The noise jitters the cell but does not weaken the control, and the stall line stays where it was.
A real injector blows through valves with a maximum opening, and so has a capacity: it delivers at the estimated phase, where is the characteristic’s half-width. It saturates at an estimated cell amplitude . That makes it nonlinear, and a nonlinear function of an unbiased estimate is a biased function of the cell.
The share of its gain the injector keeps
The averaging is exact in one limit that matters: noise fast against the cell’s growth, which takes tens of rotor revolutions while the noise changes every blade passage. Then the cell feels the injection averaged over the noise, and for a small cell, , the average is linear in with a reduced gain. Writing , the saturation amplitude over the noise, the share kept is
The first two terms are the probability that the estimate lies below saturation, where the injector is linear and passes the cell through intact. The last is the saturated part: there the injection has a fixed size and points along the estimate, so a small cell can only tilt its direction, and the tilt averages to a fraction of the linear response.
The closed form was checked by a Monte Carlo over the noise, with the same noise sample added to a cell of and of so that the difference is the injection the cell itself causes: at of 0.5, 1 and 2 the two agree to . Its limits are plain. With noise small against saturation the injector keeps all its gain. With noise large it keeps , falling to zero: an injector permanently saturated on noise points its full capacity in random directions and only the slight bias the cell gives those directions opposes it.
Between, the share falls faster than intuition suggests. With the saturation amplitude twice the noise, the injector keeps 92 per cent of its gain; with the two equal, 59 per cent; with the noise twice the saturation amplitude, 31 per cent. The capacity that mattered for sizing the injector against a large cell is also what decides how much noise it can tolerate on a small one.
The stall line moves back
With a reduced gain the noiseless rule still holds, at the reduced value: the cell is held where .
At a gain of 0.7 the noiseless injector holds the machine to 0.774 of its peak flow: 22.6 per cent of margin bought. At it holds to 0.798, and a tenth of the margin is gone; at to 0.883, and half of it is gone. The weaker injector, at a gain of 0.4, loses proportionally more, because its margin was smaller to begin with: from 0.887 to 0.937 at , more than half of its 11.3 per cent. The phase lag multiplies the loss rather than adding to it, because both enter as factors of the same term: a lag of one radian and noise at together leave the injector at a gain of 0.7 holding to 0.940, which is 27 per cent of its noiseless margin.
The direction of the effect is the one a designer would not guess from the estimate’s statistics. Noise that averages to nothing in the estimate averages to a weaker controller, and the weakening is a property of the actuator’s saturation, not of the sensors. An injector twice as large, with the same gain, has twice the saturation amplitude and so twice the : at doubling the capacity takes the share from 0.59 to 0.92, and that is worth more than doubling the number of sensors.
A ceiling on the gain
The rule that a larger injector beats more sensors points to a sharper statement about the gain itself. The saturation amplitude is , so for a fixed valve and fixed noise falls as the gain is raised: turning up the gain makes the injector saturate on smaller estimates, and so on more of the noise. The effective gain is then , and raising both multiplies it and erodes it.
The two effects do not cancel; the product rises with the set gain and levels off. As grows without limit the injector becomes a relay, blowing its full capacity at the estimated phase whatever the estimate’s size, and its effective gain on a small cell tends to . That is a ceiling no setting of the gain can pass: with capacity and noise fixed, the best held flow is the one at a gain of , and every finite gain does worse. At a set gain of 0.7 gives an effective 0.54; a set gain of 2 gives 0.62; an infinite one 0.63.
The ceiling is the noise doing something useful. A relay with a perfect sensor has no small-signal gain at all — it is either full on or off and has no linear regime to hold a small cell with — and it chatters. With noise in its estimate, the relay’s output direction is smeared over angles, and its average response to a small cell becomes linear, with a slope set by how widely the noise smears it. This is dither, the old device of adding noise to a relay to linearise it — the same averaging that lets a law be exact as an average when no instance obeys it — arising here without being added. So the noise both takes away the gain a linear injector would have had and gives a saturating one the only small-signal gain it can have, and the ceiling is where those two balance.
For a designer the consequence is that the injector’s capacity and the estimate’s noise enter only as their ratio. With fixed, the held line is fixed; to move it, either the valve must be larger or the estimate quieter. The gain is the one parameter that cannot help past a point, and it reaches that point quickly: at ninety per cent of the ceiling is reached at a set gain of 0.8.
What the sensors buy
The noise per component of the estimate falls as , so for a given noise per sensor grows as . Sensors buy back the margin, but only as the square root of their number.
With each sensor as noisy as the saturation amplitude, six sensors hold the machine to 0.813 of its peak flow and eight to 0.798, against 0.774 for a perfect sensor: the two extra sensors buy back 1.5 points of margin. With each sensor twice as noisy, eight sensors hold only to 0.883, and it takes thirty-two to get back to 0.798. Going from six sensors to eight buys what doubling the injector’s capacity does only when the noise is already small; when it is not, the injector’s size is the cheaper lever.
The averaging, checked against noisy cells
The reduced gain rests on averaging the injection over noise. That was checked directly. An ensemble of 1,500 small cells, each started at an amplitude of 0.01 at a flow where , was integrated with the full nonlinear cell equation and a fresh noise sample in its estimate at every step, injected against at a gain of 0.4 with a saturation amplitude of 0.1. Noiseless, that gain holds the cell, decaying at .
At the ensemble decays at 0.0189 per rotor radius against 0.0201 averaged; at at 0.0127 against 0.0141. At it grows, at 0.0140 against 0.0130: a cell that the injector held when it could see perfectly escapes from it when it cannot, exactly as the reduced gain says. The crossing, where , is at . Close to the crossing the fitted rate is small and the relative agreement worse — 0.0029 against 0.0042 at — because the growth is then slow enough that the ensemble’s own scatter is a large part of it.
Why the line moves rather than blurs
It would be natural to expect noise to blur the stall line — to make the boundary between held and lost a band of flows where the cell is sometimes held — rather than to move it. In the averaged picture it moves cleanly, and the reason is the separation of time scales. The cell grows or decays over tens of rotor revolutions; the noise in its estimate changes every few blade passages. Over one growth time the cell has seen thousands of independent noise samples, and what it responds to is their average effect on the injection, which is a definite number. The cell does not get lucky on some revolutions and unlucky on others; it feels a weaker injector, all the time.
That is also what makes the effect easy to underestimate in a test. Measured at a comfortable margin, a noisy controller and a perfect one behave almost identically: the cell is small, the injector is far from saturation when it matters, and both hold. The difference appears only when the flow is pushed towards the line, where the cell must be held at the amplitudes at which the injector is most often saturated by its noise. A controller tuned at a comfortable margin, with its gain set from a perfect-sensor model, can therefore hold every test point and still lose the cell at a flow the model said it would hold — by exactly the difference between the gain and the effective gain.
The same averaging tells how to see the effect without risking the machine. The effective gain is the slope of the mean injection against the cell’s amplitude at small amplitudes. It can be measured with the machine safely held, by injecting a small known synthetic cell into the controller’s estimate and recording the mean injection it adds. Measured that way, the reduced gain gives the moved line directly.
What a noisy cell does that a mean cannot show
The ensemble mean decays where the averaged rate says it should, but each member of the ensemble is a cell kicked about by the noise, and its amplitude does not settle at zero. Around the held state it fluctuates with a variance set by the noise that the injector feeds back into it and by how strongly the reduced gain damps it — and the damping, , goes to zero at the moved line. Near the line the held cell’s fluctuations therefore grow without limit, and a capacity-limited injector has a basin: the noiseless calculation found the largest kicked cell it can survive, nearly three times its capacity at a margin of ten per cent. A fluctuating cell that wanders past that basin’s edge escapes into deep stall without any outside kick at all, an instability that, once past the edge, feeds itself as a roll that feeds itself does.
So noise costs the injector twice. Once in the mean, as the reduced gain that moves the line; and again near the line, where the fluctuations it drives can carry the cell out of a basin that shrinks to nothing as the line is approached. The first is computed here exactly. The second is a rare-event problem, a mean escape time that falls exponentially with the basin’s depth over the noise, and is what the continuation below asks for.
What the model leaves out
The cell is the Moore–Greitzer first harmonic at a fixed flow, with the surge mode held by the throttle as before; a real cell has higher harmonics, which the least-squares estimate aliases into the first when is small — with six sensors the fifth and seventh harmonics are indistinguishable from the first — and a growing cell sheds energy into them. The noise is white and independent from sensor to sensor; the blade-passing tone is neither, and a real controller filters it out, which lowers the noise but adds a lag, and the lag multiplies the gain by on top of . The averaging needs noise faster than the cell’s growth; a slowly drifting sensor offset is not averaged and biases the estimated phase instead.
And the injector saturates sharply. Real valves saturate softly, and the closed form is the limit of a hard limit; a soft one keeps somewhat more of its gain at the same .
The conventions in the numbers
Flows are Moore–Greitzer’s, with the peak of the uncontrolled characteristic at , so a held flow of 0.774 is 77.4 per cent of the peak flow. The cell amplitude is its flow amplitude over ; the saturation amplitude is in the same units, and so is the noise per component . Time is in rotor radii of travel. The phase lag is the injector’s, measured behind the cell, and enters only as .
Who measured the cells
Moore and Greitzer’s model of 1986 gave the cell and surge equations used here, on the cubic characteristic whose peak the work out of a change of swirl sets. Active control of rotating stall by sensing the first harmonic with a ring of wall-pressure transducers and acting on it was demonstrated by Paduano, Epstein, Greitzer and their colleagues at MIT in the early 1990s, first with moving inlet guide vanes and then, by Day at Cambridge and by Weigl and colleagues at MIT, with injected air at the tips. The experimenters reported that the injectors’ capacity, not their bandwidth, limited what they could hold, which is the property the closed form here turns on.
Still open: how long a held cell lasts
The mean says where the line is. Near it, the held cell is a noisy particle in a well whose rim is the injector’s basin edge, and the mean time it takes to escape is the number an operator needs: an engine held at a margin that it leaves once an hour is not held. The calculation that would follow integrates long single runs of the noisy cell at flows approaching the moved line, counts escapes into deep stall, and asks whether the escape time follows Kramers’s law, exponential in the well’s depth over the noise’s strength, with the depth set by the basin the noiseless calculation found. If it does, the margin an injector can safely hold for a given hour is a closed form in the capacity, the gain, the number of sensors and their noise.
Shares its objects with
Essays naming at least two of the same things, that neither author linked.
- A slow bush quickens the hunt it cannot start — both name dynamical system, model limit, stability
- A stall that is a place — both name model limit, stability, stall
- A trip deeper than the film's window flips the bearing twice a cycle — both name dynamical system, model limit, stability
- A warm bush stops the bearing hunting — both name dynamical system, model limit, stability
- Matched at one speed and at no other — both name model limit, stall, turbomachine
- A blade worn back onto its film stops at the cliff's edge — both name model limit, stability
Named objects
A dashed tag is an object no other essay names yet.
Dynamical systemFeedbackModel limitStabilityStallStatisticsTurbomachine