A room's warm layer stands where the vents say, whatever the heat
Put a heater in a room with a low vent and a high one. A plume rises from the heater, entraining air as it goes, spreads under the ceiling, and a warm layer forms and drains through the top vent. Double the heating and the plume carries more, and the layer's warmer, so its outflow is faster, and the two changes exactly cancel. The height of the warm layer's lower edge does not change at all. Linden and his colleagues found in 1990 that it depends on the vents' area and the room's height and on nothing else, which means a building can be sized for a clear breathing zone without knowing how many people will be in it.
Walls let a turbine beat Betz, and the channel takes it back
A turbine in open water can take at most 16/27 of the power flowing through its own area. Put the same disc in a channel whose walls stop the flow from going round, and the limit becomes 16/27 divided by the square of the area left open: well above one, at a blockage of a half. The extra is not taken from the water that passes through the disc. It is taken from a head the walls force across the whole channel, and a real channel driven by a fixed head pays for it in flow.
A Pitot tube lying on the wall reads the wall's friction
The force a fluid exerts along a surface is the hardest thing in a wall flow to measure, because it acts on a skin that cannot be separated from the body it covers. In 1954 J. H. Preston measured it with a hypodermic tube resting on the surface, reading a pressure. It works because the inner part of a turbulent layer has no memory of the flow outside it, so the pressure a small tube reads near the wall can depend on the friction and on nothing else. The law that makes it work also says where it stops.
Schrenk's half-and-half is right at one aspect ratio
In 1940 Oskar Schrenk told stress engineers they could draw a wing's span load without solving anything: average the planform's chord with an ellipse of the same area. It works to two or three per cent inboard, and to under one per cent in the number a spar is sized from. Against the lifting line it was meant to replace, the half turns out to be the right weight only on a wing far longer than any it was used on, and its square tip carries a load that no wake could pay for.
An exact transonic flow with no shock ends at a fold
A transonic flow — subsonic in one place and supersonic in another — is usually taken to need a shock to bring the supersonic pocket back down. In 1940 Friedrich Ringleb wrote one down in closed form that has none: a gas turning round the end of a plate, accelerating through the speed of sound and decelerating back, smoothly, as an exact solution of the equations. It has a price. Push it a little further and it reaches a line where the fluid's acceleration is infinite and the formulas fold back on themselves, and no flow exists past it.
A pool of syrup spreads as the eighth root of time
Pour syrup onto a table and it spreads, quickly at first and then so slowly that it seems to have stopped long before it has. Lubrication theory, the same approximation that carries a bearing's load on a film, says exactly how slowly: the radius grows as the eighth root of time, with a constant of 0.894 that follows from the shape of the pool, a dome whose thickness falls to zero at the edge as a cube root. To double its radius a pool needs two hundred and fifty-six times as long, and a litre of golden syrup takes nearly three hours to reach the size surface tension finally allows.
An ocean's interior flows at the wind's curl over beta
The winds over the North Atlantic blow east in the north and west in the south, and nowhere north or south. The water beneath them, over the whole width of the ocean, drifts south. The reason is one balance, written down by Harald Sverdrup in 1947: the wind's curl twists the water columns, the only way a column on a rotating sphere can take a twist is by changing latitude, and the transport that follows is the curl divided by how fast the rotation changes northward. Twenty-eight million cubic metres a second, from a wind stress of a tenth of a pascal — and all of it has to come back north in one narrow current on the western side.
The Obukhov length is where buoyancy takes over from the wind
Near the ground the wind's turbulence is fed by two things, the drag of the surface and the heating or cooling of the air by it. In 1946 Alexander Obukhov combined them into a single length, the height above which buoyancy matters more than shear, and from it every profile in the lowest tens of metres of the atmosphere follows as a function of one ratio. Measured in Kansas in 1968, the functions bend the logarithmic wind law in opposite directions by day and by night, and they say something odd: however stable the layer is made, its Richardson number stops at a fifth, short of the quarter that theory names as the threshold.
The ring in the sink is where the film runs out of momentum
A tap running onto the flat bottom of a sink spreads into a thin, fast, glassy disc, and a few centimetres out the disc ends abruptly in a raised ring of slow water. The ring is a hydraulic jump bent into a circle. Where it sits is decided by two things nobody looks at: a boundary layer climbing up through a film a third of a millimetre thick, and the depth of the water outside. The film is still moving at three times its own wave speed when it jumps.