de Laval nozzle — where it appears
Named by 5 essays across one field — each of them below, with the objects they name alongside it.
The duct that works backwards
Squeeze a pipe and the flow speeds up. Everyone knows this, it follows from continuity, and above the speed of sound it is false — a narrowing duct decelerates a supersonic stream, because the density is falling faster than the speed is rising.
The throat that stops listening
Lower the pressure downstream of a nozzle and more gas flows through it. Keep lowering it and, at a definite point, the flow stops responding — not gradually, but completely, because the news that the pressure has fallen can no longer travel upstream.
One area, two answers
The area of a duct at a station fixes the Mach number there — twice over. A ratio of 2.5 is satisfied at Mach 0.24 and again at Mach 2.44, nothing local chooses between them, and where the choice cannot be made consistently a shock appears inside the duct to join the two.
The jet a cone sprays sideways
The one-dimensional nozzle sends all its gas straight out along the axis. A real divergent section is a cone, and the gas leaves it as a spray of straight lines from the cone's apex. Only the axial part of that momentum pushes, and the share that does is (1 + cos α)/2 — 98.3 per cent at fifteen degrees, 93.3 at thirty — whatever the gas, the Mach number or the area ratio, and it touches the momentum and never the pressure.
Friction moves the sonic point past the throat
A choked nozzle is sonic at its throat — in a nozzle with frictionless walls. With friction the flow reaches Mach one where the section's widening rate has caught up with the friction, which is downstream of the throat, and the throat itself is subsonic. The solution through that point is a saddle that can only be found from the inside, and the mass flow it passes is less than the throat's area allows.
Named alongside it
The objects these essays reach for when they reach for this one.
Area machMach numberChokingSonic throatStagnation pressureIsentropicModel limitBack pressureBoundary-valueCompressibilityContinuityControl volume