Concept

Energy equation — where it appears

The accounting of work and heat that accompanies the momentum equation, and the only place where temperature enters an aerodynamic problem. It is what makes a compressible flow different from an incompressible one solved twice.

Named by 12 essays across 4 fields — each of them below, with the objects they name alongside it.

Efficiency is decided before the engine is chosen. Froude's propulsive efficiency against the ratio of jet speed to flight speed. It is 2/(1+σ) and nothing else — no engine, no fuel, no combustion. A turbojet with a jet at three times flight speed cannot exceed 50% however good its core is, and a propeller moving a great deal of air slowly is above 90% before anybody has designed anything.

A big slow push

The same thrust can be had from a lot of air moved a little or a little air moved a lot, and the two are not equivalent. One number decides which, it contains no engine, and it is why every airliner built since 1970 has a fan far larger than the machine driving it.

applied · Actuator disc
The energy is all there the whole way: enthalpy spent to buy speed. At each Mach number, the fraction of the stagnation enthalpy still held as heat and the fraction converted into directed motion. The two always sum to the total, which is the compressible replacement for Bernoulli's equation — an energy statement rather than a pressure one. At Mach 2 more than four fifths of the heat has become speed.

Energy instead of pressure

Bernoulli's equation is a statement that pressure and speed trade against each other at fixed density. Take the fixed density away and the trade is between heat and speed instead — and what survives is not a pressure at all.

compressible · Bernoulli's equation
Two heights, and only one of them is in the answer. A siphon, with the two heights that get confused. The drop from the source surface to the outlet is what drives the flow: the exit speed is √(2gΔz) = 4.43 m/s and nothing else enters it. The rise to the crown decides the pressure at the top — 72.0 kPa absolute here, against an atmosphere of 101.3 — and therefore whether the column holds together at all. A siphon over a high wall and one over a kerb, draining to the same place, flow at exactly the same rate.

The siphon that does not need the air

A siphon is explained everywhere by the atmosphere pushing the liquid over the hump. The flow rate says otherwise, in the flattest way available — the height of the hump does not appear in it at all. What the atmosphere does is hold the column together, which is a different job with a different limit.

misconceptions · Siphon
What the skin settles at, before anything is done to it. The adiabatic wall temperature against Mach number, in air at 216.7 K, with the stagnation temperature above it. The gap between the two is the recovery factor, which is 0.8417 here and stays there at every Mach number — it is a property of the Prandtl number and not of the speed. At Mach 2 the skin sits at 363 K, at Mach 3 at 545 K, and at Mach 5 at 1128 K, which is past what aluminium will do. Nothing has been burnt and nothing has been rubbed: the air was brought to rest, and this is where its kinetic energy went.

The wall that heats itself

A surface told nothing about its temperature does not settle at the air's. It settles most of the way to the stagnation temperature, and the heat flux is driven from that invented temperature rather than from the free stream's — so a wall hotter than the air can be being heated by it.

compressible · Recovery
A material region, and the dye that stays inside it. The same fluid at four times, carried by an unsteady straining flow whose strain rate oscillates. The outline is a circle of the fluid at the first instant, tracked by integrating the velocity field; the shading is a blob of passive dye. The region is stretched to nearly seven to one and its area is unchanged to fifteen decimal places, because the flow is incompressible. The amount of dye inside it is unchanged to thirteen, because the dye is carried by the same fluid.

A rate of change that will not hold still

Three boxes drawn in one flow at one instant give three different answers to how fast the dye inside them is changing — one falling, one falling twice as fast, one rising. All three reconcile with a single material rate, and that rate is zero.

kinematics · Transport theorem
Nothing can deliver more than h/H, and here that is 10.0%. The fraction of the supply a ram can deliver, against the height it is asked to deliver to, from a supply falling 2 m. The upper curve is the exact ceiling h/H, which follows from the energy audit with every loss set to zero and can be reached by no real machine; the lower one is what a ram at 65% efficiency actually sends. Asking for twice the height halves the delivery, exactly, and there is no design that escapes it.

A pump with no engine

A hydraulic ram lifts water uphill using nothing but the water that is already falling. It has one moving part and no power supply, and everything it can and cannot do follows from an energy audit that fits on one line — including a ceiling nothing about its design can move.

applied · Water hammer
γ for air, against temperature. The ratio of specific heats for air as a mixture of nitrogen and oxygen, with the vibrational mode filling according to the Einstein function. It is 1.400 at room temperature, where only translation and rotation are available; 1.337 at a thousand kelvin; and 1.288 at six thousand. Every compressible result on this site has used 1.4, and that is the value for a gas that is not hot — which, behind any shock worth drawing, it is not.

When gamma stops being a number

Every compressible result on this site has used γ = 1.4, which counts the ways a nitrogen molecule can hold energy at room temperature. Behind a Mach 10 shock the gas is at 3,800 kelvin and the count is different — and the pressure barely moves while the temperature falls by fifteen per cent.

compressible · Real gas
The shock radius against time, from an equation that was given no exponent. The thin-shell energy balance integrated forward from a small initial radius, on logarithmic axes. The two-fifths power is not put in: the ordinary differential equation is Ṙ = √(E/AρR³), and the straight line is what it does. The fitted slope is 0.39983 and the fitted prefactor is 0.90721 against a closed form of 0.90702 — the small residuals being the integration's memory of where it started, which the similarity solution has no equivalent of.

A radius that gives the energy away

Four quantities, three dimensions, one group. The radius of a strong blast must be a constant times (Et²/ρ)¹⁄⁵, and nothing about the device, the chemistry or the initial size can appear. The exponent is free and the constant is not.

compressible · Blast wave
The source falls 6 m and the crown pressure does not move. The pressure at the crown of a draining siphon, against time, as the source level falls from the top of the tank to the end of the run, a drop of 6 m. It is flat to 1.5e-11 pascals — not nearly flat, exactly flat, because the two effects of a falling source cancel identically. Losing a metre of level shrinks the drop, which slows the flow and raises the crown pressure by half a velocity head; and it grows the rise, which lowers the crown pressure by ρg per metre. Those are the same number. So a siphon that starts will not break as it drains, however far the level falls, and the run ended because the level reached the outlet instead.

The siphon that does not break

A draining reservoir shrinks the drop and grows the rise at the same time, and the siphon's own coupling — a metre of extra drop costs a metre of hump — says a siphon should break as it empties. It does not. The two effects cancel exactly, and the crown pressure of a draining siphon is a constant that does not contain the source level at all.

misconceptions · Siphon
Friction lends the crown 28.4 kPa, and the tank takes it back. The absolute pressure at the crown of a siphon with friction in its hose, through a whole drain, for the crown placed at three positions along the hose, against the frictionless constant of 23.01 kPa. With the crown 0.3 of the way it starts at 63.3 kPa, with the crown 0.5 along it starts at 51.5 kPa and with the crown 0.7 of the way it starts at 40.4 kPa. Every curve is above the constant, every curve falls towards it as the level falls, and every curve reaches it at the end — 23.06 kPa with a centimetre of level left. Friction never brings a siphon nearer to breaking; it lends a margin, and the draining tank returns it pascal by pascal, so the worst the crown ever sees is the frictionless value.

The margin friction lends a siphon

Without friction a draining siphon's crown pressure does not depend on the source level at all, and every real hose has friction. It turns out always to raise the crown pressure, by an amount the draining tank hands back pascal by pascal — and how much it lends is decided by where along the hose the crown sits, not by how rough or how narrow the hose is.

misconceptions · Siphon
A cooled wall at β = 1: the linear relation is 158 K out inside the layer. The static temperature across a laminar layer at Mach 5 with an edge temperature of 220 K, over a wall whose total enthalpy is 0.5 of the edge's, at a pressure gradient β = 1: exact (thick) and from the Crocco–Busemann linear relation (thin), at a Prandtl number of one with constant properties. The wall is at 660 K in both. The exact profile peaks at 684 K and the linear one at 759 K; the largest difference, −158.3 K, is at η = 0.81.

The gradient the heat never hears

On a flat plate at a Prandtl number of one, a boundary layer's total enthalpy is a straight-line function of its velocity, whatever the wall's temperature. Put the same layer in a pressure gradient and the straight line fails everywhere except on an insulated wall, because the gradient enters the velocity's equation and not the enthalpy's — and a favourable gradient can leave a band of gas colder than the free stream above a wall three times hotter than it.

compressible · Recovery
The best efficiency runs from nine-eighths of φ² to one. The best efficiency a peristaltic pump can reach, against the fraction of the channel its wave closes, with its two limits. For a shallow wave it is 9φ²/8, which is small — a wave closing a fifth of the channel is at best 4.5 per cent efficient. As the wave closes the channel the best efficiency tends to one, and its shortfall shrinks in proportion to the remaining gap: about 1.9(1 − φ). Nothing in between is independent of the amplitude.

The pump that is better the more it squeezes

A waving sheet swims at a cost per metre with no amplitude in it. A waving wall pumping fluid is the same mechanism turned round, and its efficiency is nothing like that: it starts at nine-eighths of the amplitude ratio squared, is exactly 2 − √3 at half closure, and rises towards one as the wave closes the tube — where the pump stops being a wave and becomes a piston.

kinematics · Continuity

Named alongside it

The objects these essays reach for when they reach for this one.

Model limitMeasurementAbsolute pressureBarometric heightControl volumeEfficiencyMach numberMisconceptionSiphonStagnation temperatureVapour pressureAerodynamic heating

All concepts