Regimes and numbers

A drop in turbulence answers to whichever number its size picks

In a slow stirred flow a drop breaks when viscous stress beats surface tension, which is a capillary number, as Taylor showed in the 1930s. In a violently turbulent flow it breaks when the eddies' pressure beats tension, which is a Weber number with no viscosity in it. These are different laws with different exponents, for what looks like one process. Which one applies is decided by the drop's own size against the smallest eddy in the flow, so a flow can pass from one to the other, and a homogeniser and a syrup mixer are on opposite sides of a line that can be calculated.

Worth reading first: The number that cannot break a drop · Where the energy goes.

The number that cannot break a drop followed a drop in a smooth flow, the problem G. I. Taylor set in 1934. A slow flow stresses a drop, and tension holds it together, and the ratio of the two is the capillary number Ca=μγ˙a/σCa=\mu\dot\gamma a/\sigma. If it’s above a critical value that depends on the viscosity ratio, the drop breaks. That’s a tidy law for a smooth flow of known shear. Yet most drops ever made have been made by something very different: a turbulent flow in a mixer, a homogeniser, a pipe, a breaking wave, a bubbling reactor. No shear rate exists in the usual sense, because the flow has a whole spectrum of them.

Kolmogorov and Hinze each answered this, independently, within a few years of each other in about 1950. Their answer contains no viscosity. It says that a drop in a violently turbulent flow is broken by the pressure difference across it due to eddies of its own size, and it uses the same universal idea as the energy cascade. The law they arrived at is one of the oldest successes of turbulence theory:

dmax⁡=0.725(σρ)3/5ε−2/5.d_{\max}=0.725\left(\frac\sigma\rho\right)^{3/5}\varepsilon^{-2/5}.

So here are two laws for what looks like the same process, the breaking of a drop in a flow. One has viscosity in it and the other doesn’t. They have different powers of the stirring. What’s more, the regime in which Taylor’s law holds is one that a turbulent flow can reach too, at small enough scales. This essay finds out where the line is, and it isn’t where it might be expected. Water stays on one side of it almost no matter what’s done to it.

Harder stirring moves a drop from one law to the other at the point where it fits inside the smallest eddyLargest stable drop against dissipation, at a tension of 30 mN/m and a carrier of 1 mPa s. Hinze's inertial law falls as ε⁻²ᐟ⁵ and the capillary law as ε⁻¹ᐟ². Kolmogorov's length falls as ε⁻¹ᐟ⁴, and it crosses Hinze's at a dissipation of 9.49·10¹⁰ W/kg, at a size of 0.057 µm. Above the crossing, Hinze's law would have a drop smaller than the eddies it says are breaking it.10⁰10¹10²10³10⁴10⁵10⁶10⁷10⁸10⁹10⁻²10⁻¹10⁰10¹10²10³10⁴10⁵dissipation, W/kgsize, µmKolmogorov's lengthinertial, Hinzecapillary, TaylorWeber's balance above Kolmogorov's length and the capillary number below it, with one tensiona dilute emulsion, Weber and capillary numbers near one, Re high for the carrier
Fig. 1 Largest stable drop against dissipation, at a tension of 30 mN/m and a carrier of 1 mPa s. Hinze’s inertial law falls as ε−2/5\varepsilon^{-2/5} and the capillary law as ε−1/2\varepsilon^{-1/2}. Kolmogorov’s length falls as ε−1/4\varepsilon^{-1/4} and crosses Hinze’s at 9.5×10109.5\times10^{10} W/kg, at 57 nm. Dialled to 0.01 and 0.1 Pa s, the viscous carrier takes the crossing to a far smaller dissipation.

Two ways for the same stress to be felt

Consider a drop of diameter dd in a turbulent flow with dissipation ε\varepsilon per unit mass. The smallest eddies have a size given by Kolmogorov’s length, η=(ν3/ε)1/4\eta=(\nu^3/\varepsilon)^{1/4}, and the range of sizes above them goes up to the flow’s outer scale. The question is whether the drop is larger or smaller than η\eta.

If it’s larger, it sits in the inertial range. Eddies smaller than the drop can’t do much to it, as they only stir its surface locally. Those much larger than it merely carry it along. It’s the eddies of about its own size that deform it. Those eddies have a velocity difference δu∼(εd)1/3\delta u\sim(\varepsilon d)^{1/3} across the drop, by Kolmogorov’s scaling, and a pressure difference of ρ δu2\rho\,\delta u^2. Setting this against the capillary pressure σ/d\sigma/d gives a Weber number on the eddy velocity:

Wed=ρ (εd)2/3dσ=ρ ε2/3d5/3σ,We_d=\frac{\rho\,(\varepsilon d)^{2/3}d}{\sigma}=\frac{\rho\,\varepsilon^{2/3}d^{5/3}}{\sigma},

and when that passes a constant, the drop breaks. Solving for dd gives the law with the 3/53/5 and −2/5-2/5. The constant, 0.725, comes from Clay’s measurements of 1940, reinterpreted by Hinze. It gives a critical Weber number of 0.7255/3=0.5850.725^{5/3}=0.585, in these units. Viscosity’s nowhere to be seen, as it shouldn’t be: an inertial-range eddy doesn’t know about viscosity.

If the drop’s smaller than η\eta, the flow around it’s smooth. It’s bathed in a strain and rotation of the smallest eddies, with a rate of about ε/ν\sqrt{\varepsilon/\nu}. So it’s in the Taylor regime, with a capillary number on this rate:

dmax⁡=2Cac σμε/ν.d_{\max}=\frac{2Ca_c\,\sigma}{\mu\sqrt{\varepsilon/\nu}}.

Taylor’s law here has viscosity in it, and with a different power of ε\varepsilon, −1/2-1/2 rather than −2/5-2/5.

Set beside the Kolmogorov length’s power of −1/4-1/4, this gives a tidy picture. The three lines in the figure have three different slopes. A large drop in gentle turbulence is in Hinze’s regime. As ε\varepsilon rises, Hinze’s size falls faster than Kolmogorov’s, and at some dissipation the Hinze size falls below the smallest eddy. Past that point, Hinze’s law is using eddies that don’t exist. A drop that fits inside the smallest eddy is in a smooth flow, and the correct law’s Taylor’s.

The two lines don’t quite meet at the Kolmogorov crossing, which is a nice piece of consistency. Hinze’s law gives 57 nm at the crossing in water, and the capillary law gives 93 nm there, within a factor of two. The two asymptotes come close at the place where they should exchange. That’s reassuring, for each came from a separate physical argument, each with its own experimental constant.

Water never gets there

Now the surprise. Look at where the line is, for water.

The crossing is at 9.5×10109.5\times10^{10} W/kg. To grasp how far away that is, a kitchen blender dissipates of order 100 W/kg on average, and the strongest laboratory stirrer 10,000. A high-pressure valve homogeniser, the sort of device that makes milk, gets to 10710^7 to 10910^9 W/kg in a very short residence time. Even that’s a factor of a hundred short. So for ordinary mixtures of oil in water, the Kolmogorov length stays smaller than the drop, right down to the limit of practical emulsification. Hinze’s law, with no viscosity in it, is what everyone should use, and it works well. Water’s so thin that it hasn’t got a viscous regime at any reachable energy input.

With that much in hand, an estimate can be made for the homogeniser. At 10910^9 W/kg, Hinze predicts 0.35 µm, and that’s close to what’s found: homogenised milk has fat globules of about half a micron. The figure’s axes put that at the bottom right, on the inertial line, with the Kolmogorov length of 0.18 µm just below it.

The two laws meet at a dissipation with a steep dependence on the liquid's viscosity. The dissipation at which Hinze's size equals Kolmogorov's length, against the carrier's viscosity. It is 9.49·10¹⁰ W/kg in water, and 9.49·10⁵ at ten times its viscosity. With a homogeniser at 10⁷ to 10⁹ W/kg, water sits on one side and a syrup on the other.
Fig. 2 The dissipation at which Hinze’s size equals Kolmogorov’s length, against the carrier’s viscosity: 9.5×10109.5\times10^{10} W/kg in water and 9.5×1059.5\times10^{5} at ten times its viscosity. A homogeniser at 10710^7 to 10910^9 W/kg has water on one side and a syrup on the other.

The sensitivity to viscosity is huge. Setting η=dmax⁡\eta=d_{\max} gives a crossover with a very steep dependence on ν\nu, in fact as ν−5\nu^{-5}. With ten times water’s viscosity, the crossing has fallen by a factor of 10510^5, to 9.5×1059.5\times10^{5} W/kg, which any good laboratory rotor-stator can pass. At a hundred times water’s viscosity, which is a light syrup or a thick cream, it’s down to about 10 W/kg. So a viscous carrier is in Taylor’s regime for practically all stirring. A thick mixture and a thin one obey different laws, by a difference in a physical constant of less than two orders of magnitude. A process engineer who’s scaled up from water to a viscous product, using a relation proved on water, is using the wrong law, and quite possibly the wrong exponent. Vankova and her colleagues showed in 2007, by a systematic variation of viscosity and interfacial tension, that drop sizes in a narrow-gap homogeniser do cross from one regime to the other at the expected point.

That last point deserves more emphasis. Reading the exponent off a measurement will distinguish these regimes in principle: −2/5-2/5 and −1/2-1/2 differ by only a little, though, and over one decade of ε\varepsilon they differ by only a quarter in the drop size. So a typical data set doesn’t distinguish them cleanly, and that’s an old problem with a pair of nearby exponents. Viscosity’s effect is the better test. In Hinze’s regime, changing the carrier’s viscosity has no effect at a fixed ε\varepsilon. In Taylor’s regime the size goes as μ−1/2\mu^{-1/2} at a fixed ε\varepsilon, so doubling the viscosity takes off about 30 per cent, though a fixed ε\varepsilon isn’t generally how a real experiment is run.

A drop too viscous for shear

The two regimes differ in another way, which has practical significance.

Below the eddies a drop's own viscosity decides whether it can break at all. The critical capillary number against the viscosity ratio, from de Bruijn's fit to Grace's curve for simple shear: 1.71 at 0.01, 0.615 at 0.1, 0.481 at 1, 2.17 at 3. It has its minimum near a ratio of 1 and rises sharply towards 4, beyond which shear does not break the drop. Hinze's law has no viscosity in it at all.
Fig. 3 The critical capillary number against the viscosity ratio, from de Bruijn’s fit to Grace’s curve for simple shear: 1.71 at 0.01, 0.615 at 0.1, 0.481 at 1 and 2.17 at 3. It has its minimum near a ratio of 1 and rises sharply towards 4, beyond which shear doesn’t break the drop.

In Taylor’s regime, the viscosity of the drop matters a great deal. A drop much more viscous than its surroundings simply tumbles in shear, as the earlier essay on the drop showed: it rotates and doesn’t stretch. At a viscosity ratio above about 4, there’s no capillary number at which simple shear can break it. In a pure strain, it’s different, and drops break at any viscosity ratio, but then a real flow’s mix of strain and rotation has to be accounted for.

Hinze’s law has no drop viscosity in it at all, at least to leading order. A high-viscosity drop takes a long time to deform: its deformation takes a time of about μdd/σ\mu_dd/\sigma, and if an eddy’s turnover time is shorter than that, the eddy can’t get on with deforming it. That’s a correction that grows with drop viscosity and gives rise to something like a viscous Weber number, or an Ohnesorge number for the drop, and the Ohnesorge number enters here as it does for a jet. So Davies in 1985 and Calabrese and his colleagues in 1986 modified Hinze’s law, by adding a viscous stress to the surface-tension resistance. For a very viscous drop in water, the modified law moves the breakup size up substantially. So the drop’s own viscosity doesn’t stop breakup entirely in inertial turbulence, but it raises the size. Viscous oils are harder to emulsify, in any regime.

A stirred tank’s power law

Practical correlations come straight out of Hinze’s law. In a stirred tank, with impeller diameter DD and speed NN, the mean dissipation goes as N3D2N^3D^2, by the standard power number. Put that in the law and the result’s a power law in an impeller Weber number, with slope −3/5-3/5.

In a stirred tank the same law becomes a power of a Weber number, with a slope of three-fifths. Largest stable drop over the impeller's diameter, against We = ρN²D³/σ, from Hinze's law with ε about 0.5 N³D²: 0.0604 at 100, 0.0152 at 1000, 0.00381 at 10000. Measured Sauter mean diameters run at about 0.05 We⁻⁰·⁶ with a smaller constant, because the mean is not the maximum.
Fig. 4 Largest stable drop over the impeller’s diameter, against We=ρN2D3/σWe=\rho N^2D^3/\sigma, from Hinze’s law with ε\varepsilon about 0.5N3D20.5N^3D^2: 0.060 at 100, 0.015 at 1,000 and 0.0038 at 10,000. Measured Sauter mean diameters run at about 0.05We−0.60.05We^{-0.6}, with a smaller constant because a mean isn’t a maximum.

Shinnar made this into a general theory of emulsification in stirred tanks in 1961, with the We−3/5We^{-3/5} law. It’s held up remarkably well for dilute systems, and most engineers’ correlations for drop size are variants of it. Coalescence adds another mechanism at high fractions of dispersed phase. There the drop size is a balance between breakup and coalescence, and it’s a different law altogether. It also matters that the dissipation isn’t uniform. Most of it’s in the impeller’s discharge, with ε\varepsilon several hundred times higher than its average near the blade tips, and the largest stable drop’s set by the region of greatest dissipation it’s passed through. So it’s the ratio of those two that determines the prefactor in a real tank. A drop may also need many passes before it finds a large enough stress. In an experiment, the size continues to decrease for hours, because a drop near the limit breaks only when the rare, intense local stress comes along, and the intermittency of turbulence enters here too. Since the dissipation isn’t uniform in time or space, a real largest size isn’t a strict limit at all. It’s merely a size at which the time to break has become long.

Reading a drop’s regime from a mixer’s behaviour

There’s a straightforward test a practical person can apply, with the arithmetic above in hand. Take a mixer, with a drop of a known size in a known liquid. Compute ε\varepsilon, either from measured power or from a power number, and work out η\eta. If the drop’s bigger, it’s inertial, and adding some glycerine to the water won’t change it until the Kolmogorov length grows past the drop. If it’s smaller, adding glycerine will shrink the drop substantially. Thus there’s a surprising prediction for food and cosmetics. Taking a low-viscosity continuous phase and thickening it in order to stabilise it can make the drops smaller, or do nothing to them. It depends on which side of the line it’s on. The behaviour isn’t monotonic: thickening the phase doesn’t change the drop size at all until a threshold. Then it gives smaller drops. And since coalescence is slowed too by a thicker film between drops, a product’s final size can improve from both directions at once, so that it isn’t easy to separate the two.

Things are different for bubbles. A bubble’s density and viscosity are negligible, the critical Weber number applies, and Hinze’s law is widely used in gas-sparged reactors. A bubble in water’s breaking law at 1 W/kg gives dmax⁡d_{\max} around 2 millimetres, if the tension’s taken as 70 mN/m, which is roughly what’s seen. The bubbles in a breaking wave have the same scale, and the Hinze scale is recognisable in measurements of the bubble size spectrum beneath breaking waves, as a break in slope around a millimetre. Above that, bubbles fragment. Below it, they don’t, and some other process sets their numbers. It’s a very general picture for a turbulent flow to have a single length scale of this sort.

Which brings out how odd the law’s history is. Kolmogorov wrote it in 1949, in a paper of four pages, as a direct application of his theory of 1941, and Hinze arrived at it independently. It’s among the first successes of what’s now called K41, and in a very real sense it’s been verified more often than any other result from that theory, by anyone with a mixer and a tray of drops. It doesn’t need a hot-wire probe or a direct simulation. The exponent of −2/5-2/5 is a direct measure of the 2/32/3 law in the inertial range, and that exponent has been measured in practical systems since the 1930s, without anyone realising its significance until the theory arrived.

What each cut costs

A further consequence of the 3/53/5 is what it says about energy.

Each tenfold cut in drop size costs three hundred times the power per kilogram. The dissipation Hinze's law asks for against the drop size wanted, in water at 30 mN/m. A 100 µm drop asks 735 W/kg, 10 µm asks 2.33·10⁵ and 1 µm asks 7.35·10⁷, which a high-pressure homogeniser can reach. In water the drop is still larger than the Kolmogorov length even there.
Fig. 5 The dissipation Hinze’s law asks for against the drop size wanted, in water at 30 mN/m. A 100 µm drop asks 735 W/kg, 10 µm asks 2.3×1052.3\times10^5 and 1 µm asks 7.4×1077.4\times10^7.

Inverting the law, ε∝d−5/2\varepsilon\propto d^{-5/2}. So a tenfold cut in drop size needs 316 times the specific power. Since the energy to make the surface only goes as 1/d1/d, a tenfold cut in size needs only ten times more surface energy. So efficiency falls drastically with decreasing size. For a 1 µm emulsion, the surface energy is about 180 J per kilogram, times the oil’s volume fraction, whereas a homogeniser working at 50 MPa spends 50 kJ on each kilogram. Under a tenth of a per cent of the work goes to making surface, and it’s all turned into heat, in common with everything else that passes through a cascade. So a homogeniser’s chiefly a water heater, one that incidentally makes emulsions. A surfactant that lowers tension is therefore valuable twice over, by the 3/53/5 power and by also stopping recoalescence.

The point of comparison with a jet breaking up is that both are capillary instabilities at bottom, once a filament has been drawn out. A drop that has been stretched by the flow breaks by capillarity in a time set by its radius. So what’s been called “breakup” is really stretching. What a turbulent flow’s doing is making a drop thin enough, for long enough, that capillary instability can take over. That’s why the time history matters, and it’s what any size law conceals.

What the law cannot show

Coalescence. In most real emulsions, drops also merge. At a volume fraction beyond a few per cent, the steady-state size is set by coalescence balancing breakup, which needs its own theory. The figures here have dilute emulsions only.

A statistical size. Real emulsions have a distribution. Hinze’s dmax⁡d_{\max} and a mean size differ by some factor, typically around 2, that varies with the system, so the figures’ sizes aren’t mean sizes.

Intermittency. A drop’s stress is rare and intense. Reasoning with a fixed Weber number ignores what’s in the dissipation’s own tail. Some measured sizes keep falling for a long time because they’re awaiting events of increasing rarity. Risso and Fabre showed in 1998 that bubbles’ breakup depends on a resonance with a series of eddies, and not a single one.

A clean interface. A real interface carries surfactant, which is not uniform on a deforming drop. Marangoni stress changes breakup significantly, and the effective tension’s a dynamic quantity, usually lower on a newly stretched drop’s tips. It’s left out. Taylor’s fit is for clean fluids.

The crossover itself. The figures treat each law as holding to the crossing, and in fact there’s a transitional range. Real drops of a size within a few η\eta see the dissipation range of the spectrum, where neither law has any right to apply. The range is about a decade wide.

The convention

dmax⁡d_{\max} is the diameter of the largest drop that survives indefinitely. ε\varepsilon is the local dissipation rate per unit mass of the carrier, in W/kg. η=(ν3/ε)1/4\eta=(\nu^3/\varepsilon)^{1/4}. Water means ρ=1000\rho=1000 kg/m³ and μ=1\mu=1 mPa s, and σ=30\sigma=30 mN/m is a typical oil-water tension without surfactant. For Taylor’s law, Ca=με/ν a/σCa=\mu\sqrt{\varepsilon/\nu}\,a/\sigma with a=d/2a=d/2, using a critical capillary number for simple shear from de Bruijn’s fit, which isn’t quite appropriate for a real strain-plus-rotation. A homogeniser’s dissipation is taken at its nominal peak.

The three numbers

The turbulent drop's numbers, and the checks on them. The eddy Weber number at Hinze's size; the fit's critical capillary number at equal viscosities; the crossing's dissipation and size for water.
Fig. 6 The eddy Weber number at the largest drop, 0.585, which is 0.7255/30.725^{5/3}; the fit’s critical capillary number at a viscosity ratio of one, 0.48; and the crossing’s dissipation and size for water, 9.5×10109.5\times10^{10} W/kg and 57 nm.

The first is a consistency check on the exponents of Hinze’s law. The second’s a check against Taylor’s measured value of around a half. A drop too viscous for shear must have no capillary-law size, and doesn’t. The model refuses a stirring of zero and a viscosity ratio less than zero.

Taylor, Kolmogorov and Hinze

Taylor’s analysis of a drop in a smooth flow dates from 1932 and 1934. Clay’s measurements of drops in turbulent flow appeared in 1940, and Kolmogorov’s paper on breakup appeared in 1949. Hinze’s 1955 paper is the usual reference. Shinnar’s stirred-tank analysis is from 1961. Grace’s curve is from 1982, and de Bruijn’s fit from 1989. Davies and Calabrese’s viscous extensions date from the mid-1980s, Risso and Fabre’s oscillating bubbles from 1998, and Vankova’s systematic study in a homogeniser from 2007.

Still open: where a viscous drop stops noticing the eddies

The viscous correction above comes from a simple addition of stresses, and it’s a rough device. The next calculation would follow a single viscous drop through a synthetic turbulent velocity field across the Kolmogorov scale, solving a simple shape-evolution model, with a resolved series of straining events. It would ask, for each viscosity ratio, how the largest stable drop’s size compares with a Hinze size modified by viscous resistance, and how much of the difference is a matter of a drop that deforms too slowly to feel an eddy before the eddy’s gone.

Shares its objects with

Essays naming at least two of the same things, that neither author linked.

Named objects

A dashed tag is an object no other essay names yet.

Capillary numberDimensionless numberDropThe Kolmogorov scaleModel limitRegimeSurface tensionWeber number