Concept

Siphon — where it appears

A tube carrying liquid up over a barrier and down to an outlet below the source. Its flow rate contains the drop between the ends and not the height of the hump, and what the atmosphere supplies is a limit on that height rather than the driving force.

Named by 8 essays across one field — each of them below, with the objects they name alongside it.

Two heights, and only one of them is in the answer. A siphon, with the two heights that get confused. The drop from the source surface to the outlet is what drives the flow: the exit speed is √(2gΔz) = 4.43 m/s and nothing else enters it. The rise to the crown decides the pressure at the top — 72.0 kPa absolute here, against an atmosphere of 101.3 — and therefore whether the column holds together at all. A siphon over a high wall and one over a kerb, draining to the same place, flow at exactly the same rate.

The siphon that does not need the air

A siphon is explained everywhere by the atmosphere pushing the liquid over the hump. The flow rate says otherwise, in the flattest way available — the height of the hump does not appear in it at all. What the atmosphere does is hold the column together, which is a different job with a different limit.

misconceptions · Siphon
The one calculation in which the atmosphere really does push. How high a partial vacuum inside the tube will raise the liquid, against the absolute pressure achieved inside it. The lift is (p_atm − p_inside)/ρg and it is capped at the barometric height of 10.11 m, because below the vapour pressure the liquid boils and pulling harder buys nothing. The horizontal lines are five crown heights: a crown below a line's intersection with the curve can be primed by suction and one above it cannot, at any pump. This is the process the running siphon's argument explicitly excluded, and it is the one where the atmospheric account is the mechanism rather than a limit.

The one place the atmosphere pushes

The height of a siphon's hump is not in its flow rate, and the atmosphere holds the column together rather than driving it. That account excludes one process by name — starting. That is the process the atmospheric account describes correctly, and it is the only one in the whole device.

misconceptions · Siphon
The source falls 6 m and the crown pressure does not move. The pressure at the crown of a draining siphon, against time, as the source level falls from the top of the tank to the end of the run, a drop of 6 m. It is flat to 1.5e-11 pascals — not nearly flat, exactly flat, because the two effects of a falling source cancel identically. Losing a metre of level shrinks the drop, which slows the flow and raises the crown pressure by half a velocity head; and it grows the rise, which lowers the crown pressure by ρg per metre. Those are the same number. So a siphon that starts will not break as it drains, however far the level falls, and the run ended because the level reached the outlet instead.

The siphon that does not break

A draining reservoir shrinks the drop and grows the rise at the same time, and the siphon's own coupling — a metre of extra drop costs a metre of hump — says a siphon should break as it empties. It does not. The two effects cancel exactly, and the crown pressure of a draining siphon is a constant that does not contain the source level at all.

misconceptions · Siphon
Friction lends the crown 28.4 kPa, and the tank takes it back. The absolute pressure at the crown of a siphon with friction in its hose, through a whole drain, for the crown placed at three positions along the hose, against the frictionless constant of 23.01 kPa. With the crown 0.3 of the way it starts at 63.3 kPa, with the crown 0.5 along it starts at 51.5 kPa and with the crown 0.7 of the way it starts at 40.4 kPa. Every curve is above the constant, every curve falls towards it as the level falls, and every curve reaches it at the end — 23.06 kPa with a centimetre of level left. Friction never brings a siphon nearer to breaking; it lends a margin, and the draining tank returns it pascal by pascal, so the worst the crown ever sees is the frictionless value.

The margin friction lends a siphon

Without friction a draining siphon's crown pressure does not depend on the source level at all, and every real hose has friction. It turns out always to raise the crown pressure, by an amount the draining tank hands back pascal by pascal — and how much it lends is decided by where along the hose the crown sits, not by how rough or how narrow the hose is.

misconceptions · Siphon
A litre of water at the crown carries 77 mL of gas it cannot hold. The volume of free gas a litre of air-saturated water can release at a siphon's crown, at the crown's own pressure, against that pressure, on a logarithmic scale, at three temperatures. It is zero at atmospheric and grows without limit towards the vapour pressure. At the reference siphon's starting crown pressure of 51.5 kPa it is 20.6 mL, a supersaturation of 2.02; at the frictionless floor of 23.0 kPa it is 76.7 mL, a supersaturation of 4.79. Cold water carries more: 87.4 mL at 5 °C. This is the equilibrium bound — what would come out if the water stayed long enough, which it does not.

The air that breaks a siphon nothing else can

A running siphon's heights cannot break it, and its friction only postpones the moment it is most exposed. What does break a siphon that has run for a day is the air dissolved in its water, which the crown's low pressure leaves the water carrying far more of than it can hold — and which gathers only once the flow is too slow to carry a bubble away.

misconceptions · Siphon
The largest nucleus decides how tall a siphon can be. The tallest crown a siphon of degassed water can run over, above the upper reservoir's surface, against the radius of the largest gas nucleus the water carries, for outlets 0.2, 1 and 3 m below the upper reservoir. Nuclei of ten microns and more leave the ordinary limit of about ten metres, where the crown reaches the vapour pressure. A largest nucleus of one micron lets a slow siphon stand 14.4 m tall; of three-tenths of a micron, 27.3 m. The water's own strength is never the limit: its dirt is.

A degassed siphon is as tall as its largest nucleus allows

The textbook says a siphon cannot lift water more than about ten metres, because above that the pressure at its crown would fall below zero. Water can hold a pressure below zero — a tension — and siphons of degassed water have run over crowns taller than the barometric height. How much taller is not set by the water's strength, which is enormous, but by the largest speck of gas it carries. A nucleus of a micron lets a slow siphon stand fourteen metres tall; three-tenths of a micron, twenty-seven. And the flow's own speed takes metres off every limit.

misconceptions · Siphon
Dissolved gas takes height from the largest nuclei first. The tallest crown a siphon runs over, against the radius of its largest nucleus at the reservoir, when a nucleus at the crown must neither break the water at once nor grow to break it by diffusion, for water at 0, 10, 30, 60 and 100 per cent of saturation. Fully degassed water gives the static limit. For a one-micron nucleus, gas below about a fifth of saturation changes nothing — 14.41 m against 14.41 — and saturated water brings it to 10.7 m. A five-micron nucleus in saturated water breaks the siphon at 2.4 m.

A crown dissolves its nuclei or breaks on them, and fast

A siphon of degassed water runs until its crown's tension reaches the breaking threshold of its largest nucleus. A nucleus lodged at the crown does not stay the size it arrived: it gains or loses gas by diffusion, and across a micron diffusion takes milliseconds, so the crown gives its verdict almost at once. Every stable nucleus loses gas unless the water holds more than half the crown's tension, and past a knee in gas content, dissolved air takes height from a siphon's crown that no amount of further degassing gives back.

misconceptions · Siphon
The pocket escapes at the least pressure its states can stand. The liquid pressure each equilibrium of the pocket needs, against the pocket's volume, for a crevice with a one-micrometre mouth in a wall the water wets at 40° and one it does not, at 110°. As the crown's pressure falls the pocket follows its curve to the right: the rim slides out of the cone, pins at the mouth, and the meniscus bulges into a cap. The curve's minimum is the escape threshold — -106 kPa for the wetting wall and -138 kPa for the non-wetting one — and below it no state exists: the pocket becomes a cavity.

A crevice keeps the nucleus a free bubble loses

A free bubble at a siphon's crown dissolves in milliseconds, so it cannot be what breaks a siphon that has run for an hour. A pocket of gas in a crack of the hose wall can be, because its meniscus is curved by the wall and need not dissolve. Followed through its equilibria, the pocket escapes at a tension set almost entirely by the crack's mouth. What the wall's wettability decides is slower and more consequential: whether the crack fills, or keeps drawing gas in until the siphon breaks.

misconceptions · Siphon

Named alongside it

The objects these essays reach for when they reach for this one.

Model limitVapour pressureCavitationAbsolute pressureMisconceptionBarometric heightLiquid tensionNucleationEnergy equationSurface tensionBubbleDiffusion